Dell PowerEdge M620 Owner's Manual page 130

Hardware owner's manual
Hide thumbs Also See for PowerEdge M620:
Table of Contents

Advertisement

Table 1-27. Blade Messages
Message
Read fault.
Remote
Configuration
update attempt
failed.
Sector not found.
Seek error.
Seek operation
failed.
Shutdown failure.
Spare bank
enabled.
System service
update required.
130
About Your System
(continued)
Causes
Faulty diskette, diskette
drive, or optical drive.
Blade could not
implement Remote
Configuration request.
Faulty diskette or hard
drive.
Shutdown test failure.
Memory sparing enabled.
The iDRAC6 Enterprise
Card flash memory may be
corrupted.
Corrective Actions
Replace the diskette. Ensure
that the drive cable is
properly connected. See
"Troubleshooting USB
Devices" on page 312 or
"Troubleshooting Hard
Drives" on page 320 for the
appropriate drive(s)
installed in your system.
Retry Remote
Configuration.
Replace the diskette. If the
problem persists, see
"Troubleshooting Hard
Drives" on page 320 for the
appropriate drive installed in
your system.
Ensure that all memory
modules are properly
installed. See
"Troubleshooting Blade
Memory" on page 319. If the
problem persists, see
"Getting Help" on page 361.
Information only.
Restore the flash memory
using the latest version on
ftp.dell.com or
support.dell.com. See the
iDRAC6 User's Guide for
instructions on performing a
field replacement of the
flash memory.

Advertisement

Table of Contents
loading

Table of Contents