Table 1-26. LCD Status Messages
Code
Text
E1114 Ambient Temp
exceeds
allowed
range.
E1116 Memory
disabled,
temp above
range. Power
cycle AC.
E1118 CPU temp
unavailable.
Review SEL.
Power cycle
AC.
E1210 Motherboard
battery
failure.
Check
battery.
E1211 RAID
Controller
battery
failure.
Check
battery.
104
About Your System
(continued)
Cause
Ambient temperature has
reached a point outside of
the allowed range.
Memory has exceeded
allowable temperature and
has been disabled to
prevent damage to the
components.
The iDRAC6 is unable to
determine the temperature
status of the processor(s).
CMOS battery is missing or
the voltage is outside of the
allowable range.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Corrective Actions
See "Troubleshooting Fan
Modules" on page 315.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting Fan
Modules" on page 315.
If the problem persists,
see "Getting Help" on
page 361.
Check the SEL for the
E1118 message details.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 361.
See "Troubleshooting the
NVRAM Backup Battery"
on page 324.
Reseat the RAID battery
connector. See "Installing
the Storage Controller
Board" on page 282 and
"Troubleshooting Fan
Modules" on page 315.