PLC-WXU300 Expand Serial Command Functional Specifications

9.11.15 CR_PIPPOSITION Command

Command
"CR_PIPPOSITION" [CR]
Details
Get position of Subpicture in Picture in Picture
Acceptable
Response
%1
Unacceptable

9.11.16 CR_STANDBYMODE Command

Command
"CR_STANDBYMODE" [CR]
Details
Get Standby Mode setting status
Acceptable
Response
%a
Unacceptable

9.11.17 CR_P-MANE Command

Command
"CR_P-MANE"[CR]
Details
Get Power management setting status
Acceptable
Response
%a
Unacceptable

9.11.18 CR_P-MANETIME Command

Command
"CR_P-MANETIME"[CR]
Details
Get time to start Power Management
Acceptable
Response
%a
Unacceptable

9.11.19 CR_ON-STA Command

Command
"CR_ON-STA"[CR]
Details
Get Power ON Start setting status
Acceptable
Response
%a
Unacceptable
"000_%1"[CR]
"BTMRIGHT" -------------- Subpicture is Bottom right
"BTMLEFT" ---------------- Subpicture is Bottom left
"TOPRIGHT" -------------- Subpicture is Top right
"TOPLEFT" ---------------- Subpicture is Top left
"Error code"[CR]
"000_%a"[CR]
"ECO" -------------- Eco Mode
"NORMAL" -------- Network Mode
"Error code"[CR]
"000_%a"[CR]
"OFF" -------------------------- Power Management is OFF
"READY" ---------------------- Power Management is Ready
"SHUTDOWN" ---- Power Management is set to Shut Down mode
"Error code"[CR]
"000_%a"[CR]
"001"~"030" -----------------------1 minute to 30 minutes
"Error code"[CR]
"000_%a"[CR]
"ON" -------------------------- Power ON Start is ON
"OFF" ------------------------ Power ON Start is OFF
"Error code"[CR]
65/72