Log Select (4C) - Fujitsu MAX3073NC - SCSI,80, Dell DC961,Hard Drive Scsi Logical Interface Specifications

Specifications
Hide thumbs Also See for MAX3073NC - SCSI,80, Dell DC961,Hard Drive:
Table of Contents

Advertisement

Command Specifications
A state appropriate to an overlapping command exception condition (see Section 1.7.1).
In cases other than the above, the sense data currently being held, or, when there are no sense data being
held, the sense data which indicate the state if an error occurred during execution of this command, are
sent to the INIT and it is terminated with a GOOD status. However, if an error which has been recovered
from by retry processing is detected during execution of this command, and if the mode which reports
"RECOVERED ERROR" is specified, this command is terminated with a CHECK CONDITION status
after sense data are sent to the INIT and sense data (RECOVERED ERROR [=1]) which indicate the
contents of that error are newly generated.
3.1.16

LOG SELECT (4C)

Bit
7
Byte
0
1
2
PC
3
0
4
0
5
0
6
0
7
8
9
0
This command provides a means for an application client to manage statistical information maintained
by the IDD about IDD. The INIT can know the types of statistical information and the current
maintaining of each statistical information by using the LOG SENSE command.
A "Save Parameters (SP)" bit is one indicates that after performing the specified LOG SELECT
operation the drive will save all parameters to the disc medium. A "SP" bit of zero specifies that
parameters is not saved. It is not an error to set the "SP" bit to one and to set the DS bit of a log
parameter to one. In this case, the parameter value for that log parameter is not saved.
The "Parameter Code Reset (PCR)" bit of one and a "Parameter list length" of zero cause all
implemented parameters to be set to zero. It also clears the SMART Failure Warning and the Thermal
Warning. If the "PCR" bit is one and the parameter list length is greater than zero, the command is
terminated with CHECK CONDITION status(ILLEGAL REQUEST [=5] / INVALID FIELD IN CDB
[=24-00]). In this case, the log paramters are not cleared. A PCR bit of zero specifies that the log
parameters is not reset.
The "Page Control (PC)" bits specifies a kind and treatment content of parameters that changed by this
command as shown below.
3-50
6
5
4
LUN
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Parameter List Length (MSB)
Parameter List Length (LSB)
0
0
0
3
2
X'4C'
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
PCR
SP
0
0
0
0
0
0
0
0
0
0
0
Link