EPSON EPL-N1600 / Duplex Unit
4.2.13 Sensor Assembly (Horizontal)
1. Remove the Duplex Unit.
2. Remove the Chute Assembly.
3. Remove the Plate Base.
4. Disconnect J2731 from the Sensor Assembly (Horizontal).
5. Press in on the locking clips and remove the Sensor Assembly
(Horizontal) from the Chute Assembly.
Rev. 0
Chapter 4
DISASSEMBLY AND ASSEMBLY
Figure 4-13. Sensor Assembly (Horizontal) Removal
F