Burner Features - Samsung GN642FFXD Installation And User Manual

Built-in hotplate
Hide thumbs Also See for GN642FFXD:
Table of Contents

Advertisement

Burner Features

Nominal heat input and flow rates see below at 15˚C at 1,013 mbar.
COUN-
TYPE OF
TRY
GAS
GB,IT
FR,HU
G-30
BE,LT
BUTANE
NL,PT
29 mbar
ES,CZ
SK
G-30
PL
BUTANE
36 mbar
GB,IT
G-31
FR,BE
LT,PT
PROPANE
ES,CZ
37 mbar
SK
GB,IT
G-20
FR,BE
LT,PT
NATURAL
PL,ES
20 mbar
CZ,SK
G-20
HU
NATURAL
25 mbar
Burner
Auxiliary
Semi-rapid
- Aeration adjustment none
BURNER
POSITION
Injector make
(1/100 mm)
Nominal heat input
(Kw)
Nominal flow rates
(g/h)
Injector make
(1/100 mm)
Nominal heat input
(Kw)
Nominal flow rates
(g/h)
Injector make
(1/100 mm)
Nominal heat input
(Kw)
Nominal flow rates
(g/h)
Injector make
(1/100 mm)
Nominal heat rating
(Kw)
Nominal flow rating
(ℓ/h)
Injector make
(1/100 mm)
Nominal heat input
(Kw)
Nominal flow rates
(ℓ/h)
Rapid
Rapid
Semi-rapid
Max
Min
Max
85
65
3.0
0.78
1.75
216
53
125
80
62
3.0
0.88
1.75
216
61
127
85
65
3.0
0.77
1.75
211
51
123
119
97
3.0
0.69
1.75
286
64
168
110
91
3.0
0.78
1.75
285
71
167
Calibrated orifice 1/100mm
25
(Table 1)
Auxiliary
Min
Max
Min
50
0.49
1.0
0.4
33
74
28
47
0.52
1.0
0.42
36
71
28
50
0.47
1.0
0.39
32
70
27
72
0.55
1.0
0.38
52
96
36
68
0.6
1.0
0.43
57
95
39
31
34
43
Total
-
7.5
-
7.5
-
7.5
-
7.5
-
7.5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gn641ffbdGn641ffxdGn641ffwdGn642ffbdGn642ffwd

Table of Contents