Chapter 7 Replacing the Consumables
3 Lift the bushing first, then pull out the shaft.
Be careful not to touch the gear near the bushing on the
shaft as it contains grease.
5
Remove the pick roller from its shaft.
Pull out the shaft as you lift the retaining clip.
Bushing
Shaft
Retaining clip
Shaft
Pick roller
Lifting the retaining clip with your fingernail may hurt or
damage your fingernail.
Use a paper clip or something alike if you have trouble
lifting it up.
2
6
Attach a new pick roller on the shaft.
Insert the protrusion on the shaft into the slot.
Pick roller
Slot
Protrusion
Shaft
Confirm that the pick roller is installed properly.
Otherwise, it may cause feeding errors such as paper
jams.
Make sure to insert the pick roller until it locks in place.
1