 Loosen the 2 screws that hold the inverter
motor board support rod.
 Pull it upwards and remove it.
 Disconnect the motor connector.
 Using a pair of pliers, detach the spring that
keeps the tensioner spring under tension.
 Remove the belt from the tensioner belt and
motor axis.
 Loosen the screws that hold the front and rear
motor fastening rods, lift them up by rotating
them and remove them by pulling them off the
rear hook.
 Slightly rotate the whole motor unit.
 Lift it up and remove.

6.11 Rotating compressor running capacitor

 Remove the worktop.
 Remove the right side panel.
 Remove the drum rotating motor.
 Disconnect the 2 connectors.
 Loosen the screws that hold the capacitor in
its slot and remove it by pulling it upwards.