Chapter 4: Test Setup And Testing; Performing Typical Test Setup; Figure 5: Typical Test Setup - Motorola MXP600 Manual

Hide thumbs Also See for MXP600:
Table of Contents

Advertisement

MN006362A01-AL
Chapter 4 : Test Setup and Testing
Chapter 4
Test Setup and Testing
This chapter provides a general overview for testing Motorola Solutions radios.
There may be some differences caused by the variety of software versions running on the testing
equipment. Please consult the user guides of the respective testing equipment for further details.
4.1

Performing Typical Test Setup

Prerequisites: Perform the following instructions before testing.
Check that the battery is fully charged (not required when using Battery Eliminator).
To test the radio, a special Battery Eliminator (PS000430A01) with RF cable is required.
Procedure:
1 Detach the antenna from the radio.
2 Connect the RF adapter (TL000147A01) at the rear side of your radio. Secure the RF adapter
with the retainer by tightening the thumb screw into the antenna nut.
3 Connect the other side of the cable to the N-type RF Connector of the IFR using an N-type-to-
SMA-adapter.
4 Connect the power supply to the battery eliminator wires.
Example:

Figure 5: Typical Test Setup

32
1
5
4
3
2

Advertisement

Table of Contents
loading

Table of Contents