Figure 9-3 Interconnect diagram of the PSON12V signal
Table 9-2 PSON12V# signal characteristics
Signal Characteristics
Signal type:PSU on/off signal
PSON12V# = Low
PSON12V# = High/Left open
Table 9-3 PSON12V# output
PSON12V# Output
Low level voltage
High level voltage
Source current, PSON12V# = Low
Signal rise and fall time

9.4 PRESENT#

The PRESENT# signal is used by the system to detect whether the PSU is present.
Table 9-4 PRESENT# signal characteristics
Signal Characteristics
Signal type
PRESENT# = Low
PRESENT# = High

9.5 INSTALLED#

The INSTALLED# signal is used by the PSU to determine whether it has been inserted into the
system.
Technical Manual
PSU side: This signal is pulled up to 3.3 V auxiliary power
supply inside the PSU by a 4.7-kilohm resistor.
System side: This signal is output by CPLD over the drive
circuit and pulled up to 3.3 V by a 10.0-kilohm resistor.
MV12 output mode
MV6 output mode
Min.
0 V
2.000 V
-
-
PSU side: The PSU interior is directly grounded.
System side: This signal is pulled up to 3.3 V by a 4.7-kilohm resistor and
output to the system CPLD over a series resistor.
The PSU is present.
The PSU is removed from the system.
9 Control Functions
Max.
0.8 V
3.465 V
1 mA
100 μs