Rear Panel
@ AC INPUT connector
Supply the rated voltage with the AC power cord provided.
® Y/C 358 OUT connector (7-pin female)
This
is an output connector for the separate Y/C signals
{C signal: 3.58 MHz) compatible with S-VHS VTRs.
Notes:
@
This connector
can be used only when the Y/C OUT
selector (one of the VIDEO
SELECT switches) in the
video camera is set to ON.
Pay attention
to it since the camera
is shipped from
the factory with this Y/C OUT selector set to OFF.
For operation of the selector, refer to the "Operation"
on page 6.
@ When using this connector, the R/G/B, Y/R-Y/B-Y con-
nectors @ cannot be used.
@ TALLY terminals
Apply a rated tally signal from a speciai effects generator
(SEG) or a switcher.
@ INTERCOM terminals
This is an input/output terminal of the intercom signal.
@ AUX VIDEO INPUT connectors (BNC)
The return video signal from a special effect generator or
switcher can be input via these connectors to be sent to the
viewfinder. When sing only one of the connectors, set the
75-ohm termination switch (75 Q ON/OFF) to ON.
@® GENLOCK connectors (BNC)
Composite video signal (VBS) or black burst signal can be in-
put through these connectors as the reference signal for gen-
locking.
when
using only one of them, set the 75-ohm
termination switch (75 2 ON/OFF) to ON.
@ R/G/B, Y/R-Y/B-Y connectors (BNC)
© These are output terminals of the R/G/B or Y/R-Y/B-Y
signals.
The
signal
selection
is performed
with
the
VIDEO
SELECT
switch
inside
the camera.
Prior to
shipment, this switch has been set to output the R/G/B
signals.
®
For setting the VIDEO
SELECT
switch, refer to the
"Operation" on page 6.
@COMPOSITE
VIDEO
signal output
terminals
(BNC)
The
composite
video signal is available from these con-
nectors. (2 output circuits, 1 Vp-p, 75 ohms)
@ CAMERA CABLE connector (26-pin female}
Connect this unit to the camera using the VC-P110 series
camera cable (optional).

Advertisement