1 1
Section 3
Installation
3.1 Unpacking
1. Lift the insert out of the wooden transport case.
2. Lift the AROFLEX out of the box with the aid of the two ropes,
taking care that the right-hand rope does not become entangled
with the tape holder of the tape punch.
3. Remove the 4 M8 bolts and large washers from the underside
of the padded wooden baseplate.
4. Take the INSERT and SPECAT keys out of the chad container.
5. Store the packing material for future use.
3.2 Installation
3.2.1. For stationary use
inside a building
1. Place AROFLEX on the desk or table, check that the mains voltage
is 220 volts, and insert the plug into a rim-earthed socket. The lamp
inside the LINE button blinks slowly to indicate that there is no
paper roll in place.
2. If AROFLEX is to be used in the line-connected mode, terminate
the line on the 8-pole line socket.
3. Provide a secure connection to a signal ground to be connected
to the wing nut at the rear of the teleprinter, next to the tape punch.
3.2.2. For mobile use in ships
and vehicles
1. Place AROFLEX on rubber cushion on top of metal baseplate,
and secure by means of four bolt-assemblies (see figure 1).
Make sure that all rubber washers and spacers fit snugly into the
holes provided on the baseplate and the rubber cushion.
Fix the metal baseplate (mounting support) to the operating
surface by any convenient means using the holes provided for this
purpose.