Page 2
Therefore, description in this document is provided for reference purpose only and constitutes neither an offer nor an acceptance. Sigenergy Technology Co., Ltd. may change the information at any time without notice.
Contents 2.1 Product Model No........................8 2.2 Appearance Introduction ....................9 2.3 Label Description ........................ 10 2.4 Supported Power Supply Methods for the Power Grid ..........11 2.5 Introduction to Typical Networking .................. 12 5.1 LED Indicator State ......................17 5.2 mySigen App Query ......................
Page 4
User Manual Revision History Version Date Description 2023.10.24 First official release. 4 / 22...
Page 5
User Manual Overview Introduction The focus of this document is to provide an overview of the Sigen PV Max (3.0-6.0) SP and Sigen Hybrid (3.0-6.0) SP inverter, including product features, networking, system operation, maintenance, etc. Readers This document is suitable for product users and professionals Sign Definition The following signs may be used in the document to indicate security precautions or key information.
Page 6
User Manual Safety Precautions Basic Information Before installing, operating, and maintaining the equipment, familiarize yourself with this document. The "Danger ", "Warning", "Caution" items described in this manual are only supplementary to all precautions. The Company shall not be liable for equipment damage or property loss caused by the following reasons: Failure to obtain approval from the national, regional power authority.
Page 7
User Manual during actual operation (for example, the actual operating temperature of the equipment is too high or too low). The equipment was stolen. The equipment is damaged after the warranty period. Safety Requirements Do not expose the device to high temperature or heat sources (such as ...
Product Model No. Product code Model No. Name Function specification Sigen PV Inverter Max 3.0 kW Sigen PV Max 3.0 SP Single Phase Single-phase string- Sigen PV Inverter Max 3.6 kW Sigen PV Max 3.6 SP type PV grid-connected Single Phase inverters are designed Sigen PV Inverter Max 4.0 kW...
User Manual 2.2 Appearance Introduction Appearance and Dimensions Port Introduction Serial No. Name Marking Dc switch DC SWITCH Decorative cover light strip connector Antenna interface Cable interface RJ45 1/ RJ45 2 AC output interface Ground screw Communication interface Sigen CommMod interface DC input interface PV1+/PV2+/ PV1-/PV2- (Reserved) Switch button...
User Manual 2.3 Label Description Symbols Definition Warning! Life at risk. The inverter has potential hazards after running. Take proper protection when operating the inverter. After the inverter is powered off, the discharge of internal components is delayed. Wait 10 minutes until the inverter is fully discharged according to the label time.
User Manual Supported Power Supply Methods for the Power Grid The grid supply methods supported by Sigen PV Max or Sigen Hybrid include TN-S, TN-C, TN-C-S, and TT. When TT is used as the power supply technique for the power grid, the voltage between N and PE is required to be <...
User Manual Introduction to Typical Networking Sigen PV Max or Sigen Hybrid is designed for grid-connected photovoltaic systems on residential rooftops. The grid-connected system consists of photovoltaic strings, inverters, distribution panels, and other components. A. PV panel B. Sigen PV Max or C.
Page 13
User Manual Site Selection Requirements Installation Environment Requirements Do not install the equipment in smoky, flammable, explosive, or corrosive environments. Do not install the equipment outdoors in areas prone to salt damage area, which are located less than 500 meters from the coastline or affected by sea wind.
Page 14
User Manual Do not install the equipment in mobile scenarios such as RVS, cruise ships, and trains. You are advised to install the equipment in a position that is easy to operate, maintain, and view indicator status. When installing the equipment in the garage, do not install the equipment ...
Page 16
User Manual Equipment Installation and Wiring Only company authorized personnel should install and connect the equipment. For details, see Sigen PV Max (3.0-6.0) SP, Sigen Hybrid (3.0-6.0) SP Installation Guide. 16 / 22...
User Manual System Operation 5.1 LED Indicator State Indicator Color State Description Always on The DC side is connected but not running. Always on The DC side is running. The DC side is not connected. Flash The DC side is faulty. Always on The inverter is faulty.
User Manual System Maintenance 6.1 Routine Maintenance To ensure the long-term running of the equipment, you are advised to perform routine maintenance according to this section. Inspection Inspection method Power off or Maintenance content cycle System cleaning Check the device regularly for shielding Once every and dirt.
User Manual 6.3 Emergency Treatment Emergency Measures for Fire Please shut down the equipment or disconnect the main power switch when it is safe. If the fire is small, use carbon dioxide or ABC dry powder extinguisher to extinguish the fire.