Page 2
Therefore, description in this document is provided for reference purpose only and constitutes neither an offer nor an acceptance. Sigenergy Technology Co., Ltd. may change the information at any time without notice.
Contents 2.1 Product Model No........................8 2.2 Appearance Introduction ....................9 2.3 Label Description ........................ 11 2.4 Supported Power Supply Methods for the Power Grid ..........12 2.5 Introduction to Typical Networking .................. 13 5.1 LED Indicator State ......................19 5.2 mySigen App Query ......................
Page 4
User Manual Revision History Version Date Description Updated Chapter 2 Product Introduction 2024.04.19 Updated Chapter 3 Site Selection Requirements 2024.01.30 First official release. 4 / 24...
Page 5
User Manual Overview Introduction The focus of this document is to provide an overview of the Sigen PV Max (5.0- 25.0) TP and Sigen Hybrid (5.0-25.0) TP inverter, including product features, networking, system operation, maintenance, etc. Readers This document is suitable for product users and professionals Sign Definition The following signs may be used in the document to indicate security precautions or key information.
Page 6
User Manual Safety Precautions Basic Information Before installing, operating, and maintaining the equipment, familiarize yourself with this document. The "Danger ", "Warning", "Caution" items described in this manual are only supplementary to all precautions. The Company shall not be liable for equipment damage or property loss caused by the following reasons: Failure to obtain approval from the national, regional power authority.
Page 7
User Manual actual operation (for example, the actual operating temperature of the equipment is too high or too low). The equipment was stolen. The equipment is damaged after the warranty period. Safety Requirements Do not expose the device to high temperature or heat sources (such as ...
Product Model Product Function Model No. Name code specification Sigen PV Inverter Max Sigen PV Max 5.0 TP 5.0 kW Three Phase Three-phase string-type PV Sigen PV Inverter Max Sigen PV Max 6.0 TP grid-connected 6.0 kW Three Phase inverters are...
User Manual Sigen Hybrid Inverter pure PV Sigen Hybrid 8.0 TP 8.0 kW Three Phase applications or in combination with Sigen Hybrid Inverter Sigen PV modules and Sigen Hybrid 10.0 TP 10.0 kW Three Phase Hybrid SigenStor BAT for photovoltaic Sigen Hybrid Inverter Sigen Hybrid 12.0 TP storage systems...
Page 10
User Manual Port Introduction Serial No. Name Marking Decorative cover strip light interface (This interface is unavailable for Sigen PV Max) Network interface RJ45 1/ RJ45 2 DC input interface PV1+/PV2+/ PV3+/PV4+/ PV1- /PV2- /PV3-/PV4- AC output interface Communication interface Ground screw Switch button ON/OFF...
User Manual 2.3 Label Description Symbols Definition Danger! High Voltage High voltage exists inside the equipment when powered on. Do not open the casing when the equipment is running. Any maintenance or servicing operations must be performed by trained and skilled electrical engineers. Warning! Life at risk.
User Manual Supported Power Supply Methods for the Power Grid The grid supply methods supported by Sigen PV Max or Sigen Hybrid include TN-S, TN-C, TN-C-S , TT and IT. When TT is used as the power supply technique for the power grid, the ...
User Manual Introduction to Typical Networking Sigen PV Max or Sigen Hybrid is designed for grid-connected photovoltaic systems on residential rooftops. The grid-connected system consists of photovoltaic strings, inverters, distribution panels, and other components. A. PV panel B. Sigen PV Max/Sigen Hybrid C.
Page 14
User Manual It is recommended to use FE and WLAN for communication with inverter. CommMod users must top up their own 4G data plan after a period of 2 years. 14 / 24...
Page 15
User Manual Site Selection Requirements The warranty applies when the equipment has been installed properly for its intended use and in accordance with the operating instructions. Installation Environment Requirements Do not install the equipment in smoky, flammable, or explosive environments.
Page 16
User Manual The equipment will generate heat when operating. If the device is installed indoors, please ensure that the room is well ventilated. It is prohibited to cause the indoor temperature to rise significantly due to the operation of the device.
Page 18
User Manual Equipment Installation and Wiring Only company authorized personnel should install and connect the equipment. For details, see Sigen PV Max (5.0-25.0)TP, Sigen Hybrid (5.0-25.0)TP Installation Guide. 18 / 24...
User Manual System Operation 5.1 LED Indicator State Indicator Color State Description Always on The DC side is connected but not running. Always on The DC side is running. The DC side is not connected. Flash The DC side is faulty. Always on The inverter is faulty.
User Manual System Maintenance 6.1 Routine Maintenance To ensure the long-term running of the equipment, you are advised to perform routine maintenance according to this section. Inspection Inspection method Power off Maintenance content or not cycle System Check the device regularly for Once every cleaning shielding and dirt.
User Manual 6.3 Emergency Treatment Emergency Measures for Fire Please shut down the equipment or disconnect the main power switch when it is safe. If the fire is small, use carbon dioxide or ABC dry powder extinguisher to extinguish the fire.
Need help?
Do you have a question about the Sigen PV Max 5.0 TP and is the answer not in the manual?