Sigenergy SigenStor EC 3.0 SP User Manual

Single-phase system

Advertisement

SigenStor Home
User Manual
Single-phase System
A1
Version: 01
Release date: 2023-07-31
1 / 33

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SigenStor EC 3.0 SP and is the answer not in the manual?

Questions and answers

Summary of Contents for Sigenergy SigenStor EC 3.0 SP

  • Page 1 SigenStor Home User Manual Single-phase System Version: 01 Release date: 2023-07-31 1 / 33...
  • Page 2 Therefore, description in this document is provided for reference purpose only and constitutes neither an offer nor an acceptance. Sigenergy Technology Co., Ltd. may change the information at any time without notice.
  • Page 3: Table Of Contents

    Contents 2.1 Product Introduction ......................9 2.2 Appearance Introduction ....................12 Appearance and Dimensions ..................12 Port Introduction ......................13 2.3 Label Description ........................ 14 2.4 Introduction to Typical Networking .................. 15 5.1 Working Mode........................22 5.2 LED Indicator State ......................24 5.3 mySigen App Query ......................
  • Page 4 User Manual Revision History Version Date Description 2023.07.31 First official release. 4 / 33...
  • Page 5 User Manual Overview Introduction This document mainly introduces the product introduction, networking, system operation and maintenance of the devices in the SigenStor Home single-phase system. Readers This document is suitable for product users and professionals Sign Definition The following signs may be used in the document to indicate security precautions or key information.
  • Page 6 User Manual Safety Precautions Basic Information Before installing, operating, and maintaining the equipment, familiarize yourself with this document. The "Danger ", "Warning", "Caution" items described in this manual are only supplementary to all precautions. The Company shall not be liable for equipment damage or property loss caused by the following reasons: Failure to obtain approval from the national, regional power authority.
  • Page 7 User Manual Equipment damage caused by force majeure (such as war, ⚫ earthquake, fire, storm, lightning, flood, debris flow, etc.). Damage caused by the failure of the natural environment or external ⚫ power parameters to meet the standard requirements of the equipment during actual operation (for example, the actual operating temperature of the equipment is too high or too low).
  • Page 8 User Manual Do not use the equipment with faults. If the equipment appears abnormal ⚫ (for example, battery pack leakage or appearance distortion), contact your sales agent. Carbon dioxide fire extinguishers and ABC dry powder fire extinguishers ⚫ are recommended at home. If the equipment cannot be charged, please contact your sales agent in ⚫...
  • Page 9: Product Introduction

    Inverter Product Function Model No. Name code specification Sigen Energy Controller SigenStor EC 3.0 SP 3.0 kW Single Phase Inverter; it can be Sigen Energy Controller used in SigenStor EC 3.6 SP 3.6 kW Single Phase photovoltaic Sigen Energy Controller energy storage SigenStor EC 4.0 SP...
  • Page 10 User Manual Sigen Hybrid Inverter 3.0 Inverter; it can be Sigen Hybrid 3.0 SP kW Single Phase used in conjunction with Sigen Hybrid Inverter 3.6 Sigen Hybrid 3.6 SP PV modules for kW Single Phase pure PV Sigen Hybrid Inverter 4.0 Sigen Hybrid 4.0 SP applications or in kW Single Phase...
  • Page 11 User Manual Communication Module Product Function Model No. Name code specification If it's used with our inverters, the communication Sigen Communication between inverters CommMod Sigen CommMod Module and management systems should be realized through 11 / 33...
  • Page 12: Appearance Introduction

    User Manual 2.2 Appearance Introduction Appearance and Dimensions Inverter and Battery Pack CommMod 12 / 33...
  • Page 13: Port Introduction

    User Manual Port Introduction SigenStor EC/ SigenStor AC/Sigen Hybrid Left View Name Marking Dc switch DC SWITCH Decorative cover light strip connector Antenna interface Cable interface RJ45 1/ RJ45 2 AC output interface Ground screw Communication interface Sigen CommMod interface DC input interface PV1+/PV2+/ PV1-/PV2- Switch button...
  • Page 14: Label Description

    User Manual 2.3 Label Description Symbols Definition Warning! Life at risk. The equipment has potential hazards after running. Take proper protection when operating the equipment. After the equipment is powered off, the discharge of internal components is delayed. Wait 10 minutes until the equipment is fully discharged according to the label time.
  • Page 15: Introduction To Typical Networking

    User Manual Introduction to Typical Networking The SigenStor Home energy storage system consists of photovoltaic panels, ⚫ inverters, battery packs, master control switches, loads, power grids, etc. The main function of SigenStor Home energy storage system is to store the ⚫...
  • Page 16 User Manual When B is SigenStor AC, A is not configured. ⚫ In case of home-wide backup, F2, G2, and H are not configured; for partial ⚫ backup, H can be left un-configured; in case of partial backup + zero-power grid connection control, F2, G2, and H are configured. As a backup energy source for long-term off-grid applications, the diesel ⚫...
  • Page 17 User Manual PV panel SigenStor EC/ SigenStor AC/Sigen Hybrid SigenStor BAT Electric Distribution panel Power sensor Power grid mySigen Router Antenna CommMod When B is SigenStor AC, A is not configured. ⚫ When B is Sigen Hybrid, A is optional. ⚫...
  • Page 18 User Manual Site Selection Requirements Installation Environment Requirements Do not install the equipment in smoky, flammable, explosive, or corrosive ⚫ environments. Do not install the equipment outdoors in areas prone to salt damage ⚫ area, which are located less than 500 meters from the coastline or affected by sea wind.
  • Page 19 User Manual Do not install the equipment in mobile scenarios such as ⚫ RVS, cruise ships, and trains. You are advised to install the equipment in a position that is easy to ⚫ operate, maintain, and view indicator status. When installing the equipment in the garage, do not install the equipment ⚫...
  • Page 20 User Manual The maximum operating temperature range applicable to the equipment is ⚫ -20°C to 55°C, and the recommended optimal operating temperature range is 10°C < T < 35°C. When the battery pack temperature is below 0°C, immediate charging is not ⚫...
  • Page 21 User Manual Equipment Installation and Wiring Only company authorized personnel should install and connect the equipment. SigenStor Home Installation Guide - Single-phase System A1 For details, see 21 / 33...
  • Page 22: Working Mode

    User Manual System Operation Working Mode There are two operating modes of the energy storage system: Sigen AI Mode; Self-Consumption Mode. Sigen AI Mode By recording the peaks and troughs of users' consumption habits and local electricity prices for a period of time, Sigen AI mode can customize smart electricity solutions to maximize savings for customers.
  • Page 23 User Manual Backup Reserve If there is a Gateway in the network, you can manually set the "Backup Reserve" value in mySigen App. When the grid is connected, the battery stops discharging when the set backup SOC is reached; when the grid is powered down, the battery power from the backup can be used.
  • Page 24: Led Indicator State

    User Manual 5.2 LED Indicator State SigenStor EC/ SigenStor AC/Sigen Hybrid Indicator Indicator Color State Description Always on The DC side is connected but not running. Always on The DC side is running. The DC side is not connected. Flash The DC side is faulty.
  • Page 25 User Manual Indicator Color State Description All SigenStor bats lie dormant. Flash Some SigenStor BATs are faulty. Always on All SigenStor bats are faulty. The management system is not connected. Flash Connected to local App. Always on Connected to the management system using an FE or WLAN.
  • Page 26: Mysigen App Query

    User Manual 5.3 mySigen App Query mySigen The App can be downloaded in the following two ways. For details, see App User Manual 26 / 33...
  • Page 27: Routine Maintenance

    User Manual System Maintenance 6.1 Routine Maintenance To ensure the long-term running of the equipment, you are advised to perform routine maintenance according to this section. Inspection Inspection method Power off Maintenance content or not cycle System Check the decorative cover regularly Once every cleaning for shielding and dirt.
  • Page 28: Equipment Powering-On/Power-Off

    User Manual 6.2 Equipment Powering-on/Power-off Scheme 1: App operation Tap "Setting" in mySigen APP to turn on/off the device. Scheme 2: Manual operation Follow the steps shown to remove the side and top decorative cover, and press the ON/OFF switch button. Press and hold for more than 3s to turn on or off the power;...
  • Page 29 User Manual 29 / 33...
  • Page 30: Low Soc

    User Manual 6.3 Low SOC The self-discharge characteristic of battery pack will cause power loss. If the equipment is not charged for a long time, it may be damaged due to overdischarge of power. When the battery is low, charge the equipment in time. Under normal circumstances, the equipment can charge itself according to the running condition.
  • Page 31: Emergency Treatment

    User Manual 6.4 Emergency Treatment Emergency Measures for Fire Please shut down the equipment or disconnect the main power switch ⚫ when it is safe. The high temperature may distort or damage the battery pack, resulting in ⚫ electrolyte overflow or toxic gas leakage. Do not go near the battery pack and wear protective equipment.
  • Page 32 User Manual Emergency Measures for Battery Pack Exceptions When the battery pack has abnormal odor, electrolyte leakage, or heat, do ⚫ not touch it, and contact professional personnel immediately. Professionals must wear protective equipment such as goggles, rubber gloves, gas masks, and protective clothing to protect themselves.
  • Page 33: Technical Parameter

    User Manual Appendix 7.1 Technical Parameter For details about equipment parameters, see the Data sheets of the product. 33 / 33...

Table of Contents