Contents 2.1 Product Introduction ......................9 2.2 Appearance Introduction ....................12 Appearance and Dimensions ..................12 Port Introduction ......................13 2.3 Label Description ........................ 14 2.4 Introduction to Typical Networking .................. 15 5.1 Working Mode........................22 5.2 LED Indicator State ......................24 5.3 mySigen App Query ......................
Page 4
User Manual Revision History Version Date Description 2023.07.31 First official release. 4 / 33...
Page 5
User Manual Overview Introduction This document mainly introduces the product introduction, networking, system operation and maintenance of the devices in the SigenStor Home single-phase system. Readers This document is suitable for product users and professionals Sign Definition The following signs may be used in the document to indicate security precautions or key information.
Page 6
User Manual Safety Precautions Basic Information Before installing, operating, and maintaining the equipment, familiarize yourself with this document. The "Danger ", "Warning", "Caution" items described in this manual are only supplementary to all precautions. The Company shall not be liable for equipment damage or property loss caused by the following reasons: Failure to obtain approval from the national, regional power authority.
Page 7
User Manual Equipment damage caused by force majeure (such as war, ⚫ earthquake, fire, storm, lightning, flood, debris flow, etc.). Damage caused by the failure of the natural environment or external ⚫ power parameters to meet the standard requirements of the equipment during actual operation (for example, the actual operating temperature of the equipment is too high or too low).
Page 8
User Manual Do not use the equipment with faults. If the equipment appears abnormal ⚫ (for example, battery pack leakage or appearance distortion), contact your sales agent. Carbon dioxide fire extinguishers and ABC dry powder fire extinguishers ⚫ are recommended at home. If the equipment cannot be charged, please contact your sales agent in ⚫...
Inverter Product Function Model No. Name code specification Sigen Energy Controller SigenStor EC 3.0 SP 3.0 kW Single Phase Inverter; it can be Sigen Energy Controller used in SigenStor EC 3.6 SP 3.6 kW Single Phase photovoltaic Sigen Energy Controller energy storage SigenStor EC 4.0 SP...
Page 10
User Manual Sigen Hybrid Inverter 3.0 Inverter; it can be Sigen Hybrid 3.0 SP kW Single Phase used in conjunction with Sigen Hybrid Inverter 3.6 Sigen Hybrid 3.6 SP PV modules for kW Single Phase pure PV Sigen Hybrid Inverter 4.0 Sigen Hybrid 4.0 SP applications or in kW Single Phase...
Page 11
User Manual Communication Module Product Function Model No. Name code specification If it's used with our inverters, the communication Sigen Communication between inverters CommMod Sigen CommMod Module and management systems should be realized through 11 / 33...
User Manual 2.3 Label Description Symbols Definition Warning! Life at risk. The equipment has potential hazards after running. Take proper protection when operating the equipment. After the equipment is powered off, the discharge of internal components is delayed. Wait 10 minutes until the equipment is fully discharged according to the label time.
User Manual Introduction to Typical Networking The SigenStor Home energy storage system consists of photovoltaic panels, ⚫ inverters, battery packs, master control switches, loads, power grids, etc. The main function of SigenStor Home energy storage system is to store the ⚫...
Page 16
User Manual When B is SigenStor AC, A is not configured. ⚫ In case of home-wide backup, F2, G2, and H are not configured; for partial ⚫ backup, H can be left un-configured; in case of partial backup + zero-power grid connection control, F2, G2, and H are configured. As a backup energy source for long-term off-grid applications, the diesel ⚫...
Page 17
User Manual PV panel SigenStor EC/ SigenStor AC/Sigen Hybrid SigenStor BAT Electric Distribution panel Power sensor Power grid mySigen Router Antenna CommMod When B is SigenStor AC, A is not configured. ⚫ When B is Sigen Hybrid, A is optional. ⚫...
Page 18
User Manual Site Selection Requirements Installation Environment Requirements Do not install the equipment in smoky, flammable, explosive, or corrosive ⚫ environments. Do not install the equipment outdoors in areas prone to salt damage ⚫ area, which are located less than 500 meters from the coastline or affected by sea wind.
Page 19
User Manual Do not install the equipment in mobile scenarios such as ⚫ RVS, cruise ships, and trains. You are advised to install the equipment in a position that is easy to ⚫ operate, maintain, and view indicator status. When installing the equipment in the garage, do not install the equipment ⚫...
Page 20
User Manual The maximum operating temperature range applicable to the equipment is ⚫ -20°C to 55°C, and the recommended optimal operating temperature range is 10°C < T < 35°C. When the battery pack temperature is below 0°C, immediate charging is not ⚫...
Page 21
User Manual Equipment Installation and Wiring Only company authorized personnel should install and connect the equipment. SigenStor Home Installation Guide - Single-phase System A1 For details, see 21 / 33...
User Manual System Operation Working Mode There are two operating modes of the energy storage system: Sigen AI Mode; Self-Consumption Mode. Sigen AI Mode By recording the peaks and troughs of users' consumption habits and local electricity prices for a period of time, Sigen AI mode can customize smart electricity solutions to maximize savings for customers.
Page 23
User Manual Backup Reserve If there is a Gateway in the network, you can manually set the "Backup Reserve" value in mySigen App. When the grid is connected, the battery stops discharging when the set backup SOC is reached; when the grid is powered down, the battery power from the backup can be used.
User Manual 5.2 LED Indicator State SigenStor EC/ SigenStor AC/Sigen Hybrid Indicator Indicator Color State Description Always on The DC side is connected but not running. Always on The DC side is running. The DC side is not connected. Flash The DC side is faulty.
Page 25
User Manual Indicator Color State Description All SigenStor bats lie dormant. Flash Some SigenStor BATs are faulty. Always on All SigenStor bats are faulty. The management system is not connected. Flash Connected to local App. Always on Connected to the management system using an FE or WLAN.
User Manual System Maintenance 6.1 Routine Maintenance To ensure the long-term running of the equipment, you are advised to perform routine maintenance according to this section. Inspection Inspection method Power off Maintenance content or not cycle System Check the decorative cover regularly Once every cleaning for shielding and dirt.
User Manual 6.2 Equipment Powering-on/Power-off Scheme 1: App operation Tap "Setting" in mySigen APP to turn on/off the device. Scheme 2: Manual operation Follow the steps shown to remove the side and top decorative cover, and press the ON/OFF switch button. Press and hold for more than 3s to turn on or off the power;...
User Manual 6.3 Low SOC The self-discharge characteristic of battery pack will cause power loss. If the equipment is not charged for a long time, it may be damaged due to overdischarge of power. When the battery is low, charge the equipment in time. Under normal circumstances, the equipment can charge itself according to the running condition.
User Manual 6.4 Emergency Treatment Emergency Measures for Fire Please shut down the equipment or disconnect the main power switch ⚫ when it is safe. The high temperature may distort or damage the battery pack, resulting in ⚫ electrolyte overflow or toxic gas leakage. Do not go near the battery pack and wear protective equipment.
Page 32
User Manual Emergency Measures for Battery Pack Exceptions When the battery pack has abnormal odor, electrolyte leakage, or heat, do ⚫ not touch it, and contact professional personnel immediately. Professionals must wear protective equipment such as goggles, rubber gloves, gas masks, and protective clothing to protect themselves.