Download Print this page

Sigenergy SigenStor Home Installation Manual

Single-phase system
Hide thumbs Also See for SigenStor Home:

Advertisement

Quick Links

SigenStor Home
Installation Guide
Single–phase System
A1
Version: 03
Release date: 2024-03-22

Advertisement

loading
Need help?

Need help?

Do you have a question about the SigenStor Home and is the answer not in the manual?

Questions and answers

Summary of Contents for Sigenergy SigenStor Home

  • Page 1 SigenStor Home Installation Guide Single–phase System Version: 03 Release date: 2024-03-22...
  • Page 2: Introduction To Networking

    • Trained or experienced electrical personnel are required to operate the equipment. • Operators should be familiar with national/regional laws, regulations and standards, the structure and working principle of relevant systems. Please read carefully the operating requirements and precautions in this document and “Important Notice” before operating. Failure to do so may •...
  • Page 3 S/N Equipment/component Model/version Function specification PV module – – SigenStor EC SigenStor EC Inverter; it can be used in photovoltaic energy storage scenarios and needs to be 3.0/3.6/4.0/4.6/5.0/6.0 SP used together with PV modules and SigenStor BAT. SigenStor AC SigenStor AC Inverter;...
  • Page 4 S/N Equipment/component Model/version Function specification Diesel generator – As a backup energy source for long–term off–grid applications, it can work in tandem with the Gateway to provide a smooth transition between PV, storage and diesel generator . Smart loads – Low-priority loads such as heat pumps, pool heaters, clothes dryers, and immersion heaters that can be cut off from the power supply when the stored energy is insufficient.
  • Page 5: Appearance And Dimensions

    1.3 Port Descriptions 1.2 Appearance and Dimensions Inverter and battery pack SigenStor EC/ SigenStor AC/Sigen Hybrid Left View SigenStor EC/SigenStor AC/Sigen Hybrid SigenStor BAT SigenStor BAT S/N Name Marking DC switch DC SWITCH Decorative cover light strip connector Base Antenna interface Angle Bracket (for wall mounting only) Cable interface...
  • Page 6: Pre-Installation Check

    2 Pre–installation Check • Check whether the components are entirely supplied against the packing list and whether the appearance is in good condition. For any problem, contact your sales representative. • Check personal protective equipment and installation tools to ensure that they are complete; If not, please make them up. •...
  • Page 7 • The specifications of the Installer–provided cable must comply with the cable regulations and standards of the country or region standards. • L, N and PE should be connected to other equipment in sequence without mixing. Installer–provided cable Cable name Recommended specifications Protective ground cable of inverter housing Outdoor single core copper cable...
  • Page 8: Site Selection Requirements

    3 Site Selection Requirements The warranty applies when the equipment has been installed properly for its intended use and in accordance with the operating instructions. Installation position Installation environment • Do not tilt or overturn the equipment to ensure that it is installed Do not install the equipment in smoky, flammable, or explosive •...
  • Page 9 Mounting surface • Do not install the equipment on a flammable installation base. • The installation base should meet the load–bearing requirement. Solid brick–concrete structures, concrete walls, and floors are recommended. • The surface of the installation base must be smooth and the installation area must meet the installation space requirements.
  • Page 10: Floor Installation

    4 Installation of inverter and battery pack There are two installation methods for the Base. Please refer to the actual product received for detailed instructions. • Up to six SigenStor BATs are supported for floor installation and up to two for wall installation. Option 1: •...
  • Page 11 INV1 is the mounting hole on the left side of the inverter for wall installation, while INV2 is the mounting hole on the right side for wall installation. Option 2: Calculation formula for punch height: L1 and L2 should be measured from the upper surface of the base: L1 = N x 270 mm + 261 mm ±...
  • Page 12 Before installing the handle, please use a Torque socket wrench to For details about how to place the second SigenStor BATs, see measure the screws and confirm that the screws on Sigen BAT are Steps securely tightened with a torque of 4.5 N·m (±0.45 N·m). If three or more SigenStor BATs are to be installed, use a Lift.
  • Page 13 Install the chuck screws of the decorative parts, and arrange them as Arrange SigenStor EC, SigenStor AC or Sigen Hybrid. described in Step SigenStor EC or SigenStor AC For details, see Step The chuck screws are packed in the extension package. Sigen Hybrid Remove the IP protection cover at the bottom.
  • Page 14 Base bracket has two versions in terms of appearance. The actual product shall prevail. The installation method for both versions remains the same. Appearance 1:...
  • Page 15 Appearance 2:...
  • Page 16 Steps are optional and can effectively prevent theft.
  • Page 17 4.2 Wall Installation There are two installation methods for the Angle Bracket. Please refer to the actual product received for detailed instructions. Option 1: Option 2: Wall...
  • Page 18 For details about how to place the SigenStor BAT, see Steps in Section 4.1 Floor installation. Calculation formula for punch height: For details about how to place the inverter, see Steps in Section L1 and L2 should be measured from the upper surface of the base: 4.1 Floor installation.
  • Page 19 5 Cable Connection and Component Installation Scheme II Before connecting cables, ensure that DC SWITCH is in the OFF state, and the front switch of the AC line is off. • The cable colors in the figure are used only to distinguish different lines.
  • Page 20 5.2 Protective Ground Cable of Inverter 5.3 AC Output Cable of Inverter The protective ground wire should be grounded in close proximity. Unit: mm...
  • Page 21 Click...
  • Page 22 5.4 COM terminal of the inverter • Power sensors need to be purchased from our official channel. • The appearance and specific wiring of the power sensor can be found in the instruction manual delivered with the case. Description Interface definition COM terminal of Sigen Sensor SP–DH Sigen Sensor SP–CT120–DH...
  • Page 23 5.4.1 RS485 Signal Cable of inverter Unit: mm Shielding layer 0.08–10 mm² 20–25 12–14 Click Click...
  • Page 24 5.5 RJ45 Cable of Inverter 5.6 Sigen CommMod Installation Sigen CommMod is required for 4G communication. • RJ45 cables are EIA/TIA 568B standard cables. • Two RJ45 Ethernet ports, one of which is connected to the router, and the other is connected to other devices (e.g., inverters, gateways, etc.). S/N Indicator Description –...
  • Page 25 5.7 WLAN antenna stick Installation 5.8 DC input cable of Inverter The DC cable is connected to the inverter from the PV string. Ignore WLAN communication requires the installation of WLAN antenna stick. this section in case of SigenStor AC inverters. Positive metal terminal 8–10 mm Negative metal terminal...
  • Page 26: Post-Installation Check

    6 Post–installation Check Check Item The equipment has been securely installed. Ground cables, DC cables, signal cables, etc. are installed accurately without leftovers. The cable fastening screws or terminals are properly installed. There are no sharp spikes or acute angles at the cut point of the cable tie.
  • Page 27 7 Installation of the Decorative Cover Male connector Female connector The end waterproofing plug Click for the strip light The end waterproofing plug for the strip light in step is at the lower end of the decoration on the left side of the inverter, please remove it for spare. •...
  • Page 28: Equipment Power-On

    8 Equipment Power–On 1. Turn on the front switch of the equipment. Indicator Color State Description 2. Rotate DC SWITCH to ON. (This step is not necessary for SigenStor AC) Always on All SigenStor BATs are connected 3. Observe the indicators on the front side of the inverter to learn about the but not running.
  • Page 29 After powering on the equipment, install the remaining decorative covers. Chuck screw...
  • Page 30 9 Download and create new system for mySigen APP Please enter the “Partner" → “Register Now" at the Company's official website (https://www.sigenergy.com), and complete the account registration based on facts. Download the mySigen App and create new system for the device.
  • Page 31 Already connected to the internet: Daylight Saving Time Manually locate the You can manually set Perform upgrades and modify some address, set the where necessary. function parameters of Timezone, and enter the power station. Owner Details. Upon completion of the new system creation, the installer shall inform the owner to check its "sigencloud" e–mail within 24 hours and proceed with activating its account.
  • Page 32 Not connected to the internet (that is, FE and 4G communication fault): If the equipment has already been connected to the internet, click this button and go to the Create New System page and perform operations by referring to the description in the "already connected to the internet"...
  • Page 33 Daylight Saving Time Manually locate the You can manually set Perform upgrades and modify some address, set the where necessary. function parameters of Timezone, and enter the power station. Owner Details. Upon completion of the new system creation, the installer shall inform the owner to check its "sigencloud" e–mail within 24 hours and proceed with activating its account.
  • Page 34 Sigenergy Technology Co., Ltd. Copyright © Sigenergy Technology Co., Ltd. 2024. All rights reserved. Description in this document may contain predictive statements regarding financial and operating results, product portfolio, new technology, configurations and features of product. Several factors could cause difference between actual results and those expressed or implied in www.sigenergy.com...
Save PDF