Connections - ABB Tina 10B Product Manual

Adapter unit
Hide thumbs Also See for Tina 10B:
Table of Contents

Advertisement

5

Connections

A) Smile
B) Safety controller/Safety PLC
A) Smile
M12 5-pole female, Tina 10B
1
Brown
+24 VDC
2
White
+24 VDC to Orion
3
Blue
Reset lamp
4
Black
Test/Reset button
5
Grey
(Muting lamp)
B) Safety controller/Safety PLC
M12 5-pole male, Tina 10A/B/C
1
Brown
+24 VDC
2
White
DYNlink signal input
3
Blue
0 VDC
4
Black
DYNlink signal output
5
Grey
Information
2TLC010042M0201 Rev.C
C) Orion Receiver
M12 8-pole female, Tina 10 A/B/C
1
White
Tina 10A/10C: +24 VDC
Tina 10B: Test/Reset
2
Brown
+24 VDC
3
Green
-
4
Yellow
-
5
Grey
OSSD1
6
Pink
OSSD2
7
Blue
0 VDC
8
Red
Tina 10B: Muting lamp
D) Orion Transmitter
M12 5-pole female, Tina 10C
1
Brown
+24 VDC
2
White
-
3
Blue
0 VDC
4
Black
-
5
Grey
-
C) Orion Receiver
D) Orion Transmitter
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tina 10aTina 10c

Table of Contents