Download Print this page

Mitsubishi Electric FR-A820-04750-GF Instruction Manual page 109

Hide thumbs Also See for FR-A820-04750-GF:

Advertisement

2
Compatibility with PM motor EM-A series
The PM motor EM-A series (200 V class 0.75kW to 7.5kW) is supported.
Motor model: EM-AMF[]
Applicable inverter
model
FR-A820-[]K
2.1
Selecting the PM sensorless vector control
 Initializing the parameters required for the PM sensorless vector
control (Pr.998)
• PM parameter initialization sets parameters required for driving an EM-A motor.
• Two methods of the motor parameter initialization are available: using Pr.998 PM parameter initialization, and
using IPM parameter initialization ("
Pr.
Name
998
PM parameter
E430
initialization
• To use a motor capacity that is one rank lower than the inverter capacity, set Pr.80 Motor capacity before
performing PM parameter initialization.
• When "3003, 3044, 8009, or 9009" is set in Pr.998, the motor speed which was set/monitored in frequencies is
set/monitored in motor rotations per minute. To set/monitor in frequencies, set "3103, 3144, 8109, or 9109" in
Pr.998.
• Set Pr.998 = "0" to change the PM sensorless vector control parameter settings to the parameter settings
required to drive an induction motor.
• When using an IPM motor or SPM motor other than EM-A or MM-CF, set Pr.998 = "8009, 8109, 9009, or 9109".
0.75kW
SLD
0.4
LD
0.4
ND
0.75
HD
1.5
Initial
Setting
value
range
Parameter setting (in frequencies) for an
0
induction motor
Parameter setting (in rotations per minute)
3003
for an MM-CF motor
Parameter setting (in frequencies) for an
3103
MM-CF motor
Parameter setting (in rotations per minute)
3044
for an EM-A motor
Parameter setting (in frequencies) for an
3144
EM-A motor
0
Parameter setting (in rotations per minute)
8009
for an IPM motor other than EM-A/MM-CF
(after tuning)
Parameter setting (in frequencies) for an
8109
IPM motor other than EM-A/MM-CF (after
tuning)
Parameter setting (in rotations per minute)
9009
for an SPM motor
(after tuning)
Parameter setting (in frequencies) for an
9109
SPM motor
(after tuning)
1.5kW
2.2kW
0.75
1.5
0.75
1.5
1.5
2.2
2.2
3.7
").
Description
2
3.7kW
5.5kW
2.2
3.7
2.2
3.7
3.7
5.5
5.5
7.5
The setting of the motor parameters is
changed to the setting required to drive
an induction motor.
The setting of the motor parameters is
changed to the setting required to drive
an MM-CF motor.
The setting of the motor parameters is
changed to the setting required to drive
an EM-A motor.
The setting of the motor parameters is
changed to the setting required to drive
an IPM motor. (Set Pr.71 Applied motor
and perform offline auto tuning in
advance.)
The setting of the motor parameters is
changed to the setting required to drive
an SPM motor. (Set Pr.71 Applied
motor and perform offline auto tuning in
advance.)
BCN-C22005-1008
7.5kW
5.5
5.5
7.5
11