The antenna to be used should first be checked with
a dip meter to insure that it is designed
for your
operating
band,
then
the
impedance
matching
should be checked with an SWR meter. (Fig. 8-3)
The VSWR
should preferably be less than 1.5:1 for
satisfactory operation. For antenna adjustment refer
to the antenna instruction manual.
t Adjust length
(4) Antenna matching
In general, mobile antennas have a lower impedance
than the 50-ohm
coaxial cable used to feed them,
resulting in a mismatch between the antenna and the
coax.
Such trouble
can
be eliminated
by using an
antenna tuner between the transceiver and the coax-
ial cable.
¢ Matching circuit examples
Bumper Antenna
ground
Grid Dip meter
Disconnect
OUTPUT
Coaxial cable
INPUT.
OUTPUT
oO
o
—o
Fig. 8-3 Adjusting Antenna Resonance
8-2. MOBILE OPERATION
8-2-1. Installation
Route
battery and ANTENNA
leads away
from
all
high voltage secondary
circuits to prevent
ignition
noise interference.
Loading coil _
Antenna bracket must have
To antenna terminal
good metal to metal contact
Antenna
Bumper mounting =
stand high wind stress.
Pass coaxial cable
through the drain hole.
Example of (power cord) wiring