Connecting
6.1 Wiring
6.1.5

Connecting the drive units

Connecting the connecting cable
Note the following:
Note
Only use shielded, twisted pair cables; the shield must be connected to the metallic or
metalized connector housing on the controller side. We recommend that you do not ground
the shield on the drive side. This is to separate low-frequency interferences from the analog
setpoint signal.
The pre-assembled cable available as an accessory provides the best possible immunity to
interference.
Connection of drives (e.g. SIMODRIVE 611 universal with analog setpoint interface) to the onboard
drive interface (C230-2, C240)
The figure below shows the connection of the C230-2, C240 to SIMODRIVE 611 universal
drive units.
Figure 6-8
102
Connection of a SIMODRIVE 611 universal drive unit
Operating Instructions, 11/2016, A5E33441428B
SIMOTION C