FusionSolar Smart PV Solution-Device Replacement
Commissioning Guide
Step 2 Choose Maintenance > System Maint., and import the configuration of the old
SmartLogger to the new SmartLogger3000.
Figure 5-2 Import configurations.
When a faulty SmartLogger3000 is replaced with a new SmartLogger3000, the full
configuration file does not contain certificate-related files. After the full
configuration file is imported, you need to reload a third-party certificate if
required.
Step 3 (Optional) Choose Maintenance > Device Mgmt. > Data Re-collection to
synchronize inverter information.
Issue 01 (2021-04-30)
NO TE
The parameter settings vary depending on the SmartLogger version. Set the parameters
based on requirements.
NO TICE
NO TE
In a faulty SmartLogger2000 or SmartLogger1000A is replaced with a SmartLogger3000,
the full configuration file exported from the SmartLogger2000 or SmartLogger1000A does
not contain the performance data or energy yield information of inverters. Synchronize the
data if required.