Power Saving/Night Quiet Schedule Setting - Hitachi airPoint Room700 Operation Manual

Advanced color wired remote controller
Table of Contents

Advertisement

5. Function Menu Screen Display

5.5 Power Saving/Night Quiet Schedule Setting

This function starts and stops power savings control and operation noise reduction control at the desired time.
Up to 5 Power saving/night quiet schedules can be set for each day of the week.
The power savings schedule uses the setting made in the Power Saving settings in the function menu(refer to
"5.3 Power Savings Setting").
NOTES:
When managing multiple patterns of schedules on the same day as in below examples, don't set overlapped
times zone.
If the schedule times zones overlap as in below example 2, the schedule will be canceled at the first off time
(14:00 in the case of the example 2).
Example of Power Saving
Operation and Schedule Setting
HIGH
MED
ON
LOW
OFF
08:00 10:00
12:00
1
2
Intermittent Control
Turn OFF Schedule
0
Mon
ON
Tue
Wed
Thu
Turn OFF
Turn OFF
Fri
Schedule
Schedule
Sat
Sun
OK
to turn on/off schedule
24
ON Time
1
08 : 00
2
10 : 00
3
12 : 00
14:00
16:00
18:00
4
14 : 00
4
5
3
5
16 : 00
Press Up and Down to adjust
① Schedule day and time setting (Page 25 )
(Mon) 16:30
You can set the desired time and level.
You can set up to five times a day on each day.
6
12
18
② Schedule turn ON / OFF setting (Page 26 )
Schedule operation is not performed while the schedule is disabled.
This is a function that prevents the schedule from running when not
required.
Back
Example of Power Saving Schedule Operation
Example 1 Ο
Monday Schedule
(Mon) 16:30
OFF Time
Level
~
10 : 00
LOW
12 : 00
MED
~
~
14 : 00
HIGH
~
16 : 00
MED
~
18 : 00
LOW
Back
Example 2
Monday Schedule
ON Time
OFF Time
Noise Reduction level
1
08 : 00
~
18 : 00
2
10 : 00
16 : 00
~
3
12 : 00
~
14 : 00
4
-- : --
~
-- : --
5
-- : --
~
-- : --
Press Up and Down to adjust
A16381H9HL
(Mon) 16:30
LOW
MED
HIGH
Back

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc-arfg2-z

Table of Contents