Fujitsu ETERNUS DX100 S4 Design Manual page 196

Hybrid storage systems
Hide thumbs Also See for ETERNUS DX100 S4:
Table of Contents

Advertisement

6.
Maintenance/Expansion
Hot Swap/Hot Expansion
Component
Power supply unit (PSU)
Disk (HDD)
SSD
Operation panel (PANEL)
I/O module (IOM)
Fan Expander Module (FEM) (*7)
Disk firmware
¡: Allowed / ´: Not allowed (cold swap is possible) / —: Not applicable
*1 : Mid Plane. This is a board that is located between the front (drive side) and rear (controller
(CM) or I/O module (IOM) side) of the ETERNUS DX.
*2: All of the host interfaces on the CM that will have maintenance or expansion performed go
offline. When a multipath configuration is used, switch to the host paths of the CM that will not
have maintenance performed to continue operation.
*3: System volumes must be created if Unified License is installed.
*4: Depending on the changes in the firmware, this function may require I/Os to be temporarily
stopped.
*5: Operation can be continued during a failure. The status of the ETERNUS DX can be monitored
via ETERNUS Web GUI or ETERNUS CLI.
*6: Hot expansion can only be performed when it is expanded together with a CM in a single-con-
troller configuration.
*7 : FEMs are installed in high-density drive enclosures.
Fujitsu Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Design Guide (Basic)
Hot expan-
Hot swap
sion
¡
¡
¡
¡
¡
´ (*5)
¡
¡ (*6)
¡
¡ (*4)
196
Copyright 2023 Fujitsu Limited
Remarks
P3AM-7642-32ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx200 s4Eternus dx100 s3Eternus dx200 s3

Table of Contents