Electrical and Gas leak Checks
WARNING – RISK OF
ELECTRICAL SHOCK
ALL WIRING MUST BE INSTALLED BY A
LICENSED ELECTRICIAN AND COMPLY WITH
LOCAL, STATE, AND NATIONAL ELECTRICAL
CODES.
Electrical Safety Checks
electrical wiring has been installed in accordance
with local and national regulations, and according
to the installation manual.
BEFORE TEST RUN
Check Grounding Work
Measure grounding resistance by visual detection
and with a grounding resistance tester. Grounding
NOTE: This may not be required for some
locations in North America.
DURING TEST RUN
Check for Electrical Leakage
During the Test Run, use an electroprobe and
multimeter to perform a comprehensive electrical
leakage test.
IF ELECTRICAL LEAKAGE IS DETECTED
If electrical leakage is detected, turn o the
unit immediately and call a licensed
electrician to nd and resolve the cause of
the leakage.
NOTE: This may not be required for some
locations in North America.
Page 42
Check-point of outdoor unit
.
Gas Leak Checks
gaseous leaks. Use Fig. 8.1 below as a guide for
the critical points to check for leaks.
Soap and Water Method
Using a soft brush or spray bottle, apply a soapy
water solution to all of the pipe connection points of
the indoor and outdoor units, watching to see if any
bubbles form. The presence of bubbles indicates
there is a leak.
Leak Detector Method
If using a leak detector, refer to the device's
operation/instruction manual for proper usage
instructions.
After confirming that all of the refrigerant
pipe connections points DO NOT leak, replace
the valve cover on the outside unit and wrap
and insulate the piping connections of the
indoor unit.
Check-point of indoor unit
A: Low pressure stop valve
B: High pressure stop valve
C & D: Indoor unit are nuts
D
B
C
A