Advertisement

DIMENSIONS AND DISTANCES TO BE
RESPECTED (mm)
If a hood is installed above the hob, refer to the hood
instructions for the correct distance.

INJECTOR TABLE

INJECTOR TABLE
Type of gas
Type of
used
burner
NATURAL GAS
4-crown
(Methane) G20
semi-rapid
auxiliary
LIQUEFIED
4-crown
PETROLEUM
semi-rapid
GAS
auxiliary
(Butane) G30
LIQUEFIED
4-crown
PETROLEUM
semi-rapid
GAS
auxiliary
(Propane) G31
Type of gas used
G20 20 mbar
G30 30 mbar
G31 30 mbar
POWER SUPPLY: 230 V ~ 50 Hz
20
Nominal
Injector
heating
marking
capacity
[kW]
92
3.70
95
1.65
78
1.00
92
3.70
65
1.65
50
1.00
92
3.70
65
1.65
50
1.00
Nominal
Model
configuration
capacity kW
3 burners
3 burners
3 burners
CATEGORY: II2H3+
Nominal
consumption
269 l/h
157 l/h
95 l/h
269 g/h
120 g/h
73 g/h
269 g/h
118 g/h
71 g/h
Nominal total
heating
consumption
6.35
604 l/h
6.35
462 g/h
6.35
453 g/h
IT + UK
Reduced
Gas pressure
heating
(mbar)
capacity
min. nom. max.
[kW]
1.40
0.40
17
20
0.30
1.40
0.40
25
30
0.30
1.40
0.40
25
30
0.30
Air necessary (m)
for combustion of
3
1 m
of gas
9.52
30.94
23.80
25
35
35

Advertisement