Canon Die Bonder BESTEM-D01 Manual page 36

Table of Contents

Advertisement

BESTEM – D01R
「Requirement」
1. Regarding Easy button, island recognition unit first chip offset value as standard will be automatically set.
2. Easy button setting value is in unit 1 pixel.
※ Easy button upside has a Setting button which the setting value unit is 1/100 pixel designed for minor
adjust purpose.
3. After change the chip template offset value, the template setting is no need to re-execute.
⑤ Mask region --- Select mask for template use/not use. When use, click setting button and set mask region.
⑥ Odd-Even display --- The template of the selected row is displayed.
⑦ Common(standard)/Individual select SW --- Whether whether the template is assumed to be an odd number
sequence and an even number sequence common is assumed to be individual is selected. It explains the
relation of the angle equipped with this SW and the chip.
Setting the template that has the angle by setting the angle (odd number sequence) equipped with the chip
becomes possible. For instance, when the template that inclines by 45° is set, the angle equipped with the chip
is set to 45.0.
Moreover, when the angle equipped with the chip on the even number row side is set, how many whats incline
from the angle equipped with the chip of the odd number sequence is made the template of the even number
sequence is set.
For instance, when it is a setting of 30° in odd number sequence, and the even number sequence is a template
that inclines by 70°, 40° is set angling equipped with the rotation of the even number row side.
※Please set the template again when you change the angle equipped with the chip.
Please execute it to use the specified angle when the template is registered.
(2) Die(chip) position tolerance --- Please set the DBI-Die(chip) position detect tolerance limit[±X,±Y].
When exceed tolerance limit, it is detected as position shift NG [XY unit:μm]。 But θ is fixedat10[deg].
※ If chip XY position shift still occurs after execute DBI, correction of a chip position is possible by setting up the
template offset XY in the template tab item in island recognition edit screen.