Aftertreatment Device Manual Regeneration

Manual Regeneration Procedure
When the manual regeneration is needed, screen (1) as
shown on the right side will be displayed. When screen (1)
is displayed, you need to perform the manual regeneration.
Before starting the manual regeneration, be sure to check
the following.
If the machine is equipped with a rear view camera, and the
camera is enabled, screen (1) is displayed only when the
pilot control shut-off lever is in LOCK position.
 No person is present around the machine
 Keep flammable materials away from the aftertreatment
device.
 Fuel level alarm does not light.
 DEF/AdBlue® level alarm does not light.
1. Park the machine in a safe place. Lower the front
attachment onto the ground.
2. Pull the pilot control shut-off lever to the LOCK position.
3. Set the engine control dial to slow idle.
4. Push aftertreatment device manual regeneration switch
(2).
5. When pushing aftertreatment device manual
regeneration switch (2), screen (3) as shown on the right
side will be displayed and the manual regeneration
starts. Bar graph on screen (3) indicates progress of the
regeneration process.
IMPORTANT: The manual regeneration does not start
unless the pilot control shut-off lever is in the LOCK
position and the engine control dial is in slow idle.
When touching the pilot control shut-off lever or the
engine control dial during manual regeneration, the
regeneration process is aborted. When the process is
aborted, start over again.
OPERATING THE MACHINE
5-10
1
MDC1-01-005
2
MDC1-01-543
2
MDAA-05-002
3
MDC1-01-006