Muffler Filter Manual Regeneration Request

The muffler filter needs regeneration. Usually, regeneration
is performed automatically. However, manual regeneration
is required depending on the conditions. In that case, marks
described below may be indicated on monitor (1).
This mark indicates that the muffler filter
manual regeneration is required. Perform
manual regeneration following the below
(Lighting,
procedure.
Yellow)
This mark indicates that immediate muffler
filter manual regeneration is required. Perform
manual regeneration following the below
(Blinking,
procedure.
Yellow)
This mark indicates that the muffler filter has
over collected particulate matter. Immediately
stop operation, park the machine in a safe
(Blinking,
location. Then, contact your nearest Hitachi
Red)
dealer.
This mark indicates that the muffler filter
regeneration is inhibited. It is displayed when
the manual regeneration request arises while
muffler filter regeneration is inhibited. Move
(Lighting,
the machine to a safe place. Perform manual
Yellow)
regeneration following the below procedure.
IMPORTANT:
 Manual regeneration that is performed when the
muffler filter regeneration request is displayed
restores muffler filter function. This is not a
malfunction.
 If the machine is continuously operated despite
the muffler filter regeneration request is displayed,
muffler filter alarm and engine trouble alarm will
be displayed, and the buzzer sounds. Consult your
authorized dealer for repairing the muffler filter.