Mitsubishi Electric FR-E720-0.1 K Instruction Manual page 70

Table of Contents

Advertisement

Parameter list
Func-
Parameter
Name
tion
30
Regenerative function selection
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
40
RUN key rotation direction selection
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection for reverse
43
rotation
44
Second acceleration/deceleration time
45
Second deceleration time
46
Second torque boost
47
Second V/F (base frequency)
Second stall prevention operation
48
current
51
Second electronic thermal O/L relay
52
DU/PU main display data selection
54
FM terminal function selection
55
Frequency monitoring reference
56
Current monitoring reference
57
Restart coasting time
58
Restart cushion time
59
Remote function selection
60
Energy saving control selection
61
Reference current
62
Reference value at acceleration
63
Reference value at deceleration
65
Retry selection
Stall prevention operation reduction
66
starting frequency
67
Number of retries at fault occurrence
68
Retry waiting time
69
Retry count display erase
70
Special regenerative brake duty
71
Applied motor
72
PWM frequency selection
60
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
125,
0, 1, 2
1
0
157
0 to 400Hz, 9999
0.01Hz
9999
93
0 to 400Hz, 9999
0.01Hz
9999
93
0 to 400Hz, 9999
0.01Hz
9999
93
0 to 400Hz, 9999
0.01Hz
9999
93
0 to 400Hz, 9999
0.01Hz
9999
93
0 to 400Hz, 9999
0.01Hz
9999
93
0, 0.01 to 9998
0.001
0
148
0, 1
1
0
261
0 to 100%
0.1%
10%
144
0 to 400Hz
0.01Hz
6Hz
144
0 to 400Hz, 9999
0.01Hz
9999
144
105,
0 to 3600/360s
0.1/0.01s
5/10/15s
∗2
243
105,
0 to 3600/360s, 9999
0.1/0.01s
9999
243
0 to 30%, 9999
0.1%
9999
81
0 to 400Hz, 9999
0.01Hz
9999
94
0 to 200%, 9999
0.1%
9999
88
0 to 500A, 9999
0.01A
9999
112
0, 5, 7 to 12, 14, 20,
23 to 25, 52 to 57, 61,
1
0
149
62, 100
1 to 3, 5, 7 to 12, 14, 21,
1
1
149
24, 52, 53, 61, 62
0 to 400Hz
0.01Hz
60Hz
154
Rated
0 to 500A
0.01A
inverter
154
current
0, 0.1 to 5s, 9999
0.1s
9999
157
0 to 60s
0.1s
1s
157
0, 1, 2, 3
1
0
102
0, 9
1
0
168
0 to 500A, 9999
0.01A
9999
110
0 to 200%, 9999
1%
9999
110
0 to 200%, 9999
1%
9999
110
0 to 5
1
0
165
0 to 400Hz
0.01Hz
60Hz
88
0 to 10, 101 to 110
1
0
165
0.1 to 360s
0.1s
1s
165
0
1
0
165
0 to 30%
0.1%
0%
125
0, 1, 3 to 6, 13 to 16, 23,
82, 85,
24, 40, 43, 44, 50, 53,
1
0
114,
54
116,
0 to 15
1
1
169
Customer
Parameter
Remarks
Setting
30
31
32
33
34
35
36
37
40
41
42
43
44
45
46
47
48
51
52
54
55
56
57
58
59
60
61
62
63
65
66
67
68
69
70
71
72
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
AD MFVC
AD MFVC
AD MFVC
GP MFVC
GP MFVC
GP MFVC
1E
9E
0
1F
9F
0
20
A0
0
21
A1
0
22
A2
0
23
A3
0
24
A4
0
25
A5
0
28
A8
0
29
A9
0
2A
AA
0
2B
AB
0
2C
AC
0
2D
AD
0
2E
AE
0
×
×
×
×
2F
AF
0
30
B0
0
33
B3
0
34
B4
0
36
B6
0
37
B7
0
38
B8
0
39
B9
0
3A
BA
0
3B
BB
0
×
×
3C
BC
0
3D
BD
0
3E
BE
0
3F
BF
0
41
C1
0
42
C2
0
43
C3
0
44
C4
0
45
C5
0
46
C6
0
47
C7
0
48
C8
0
Parameter list
Parameter
Copy
Clear
All clear
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents