Mitsubishi Electric FR-E720-0.1 K Instruction Manual page 222

Table of Contents

Advertisement

Communication operation and setting
List of calibration parameters
Parameter
C2 (902) Terminal 2 frequency setting bias frequency
C3 (902) Terminal 2 frequency setting bias
Terminal 2 frequency setting gain
125 (903)
frequency
C4 (903) Terminal 2 frequency setting gain
C5 (904) Terminal 4 frequency setting bias frequency
C6 (904) Terminal 4 frequency setting bias
Terminal 4 frequency setting gain
126 (905)
frequency
C7 (905) Terminal 4 frequency setting gain
[Special monitor selection No.]
Refer to page 149 for details of the monitor description.
Data
Description
Output frequency/speed ∗1
H01
H02
Output current
H03
Output voltage
Frequency setting/speed setting ∗1
H05
H07
Motor torque
H08
Converter output voltage
H09
Regenerative brake duty
Electronic thermal relay function
H0A
load factor
H0B
Output current peak value
H0C
Converter output voltage peak value
H0E
Output power
∗1
When "0.01 to 9998" is set in Pr. 37 and "01" in instruction code HFF, the data format is 6 digits (E2).
∗2
Input terminal monitor details
b15
∗3
Output terminal monitor details
b15
∗4
Details of option input terminal monitor 1 (input terminal status of FR-A7AX E kit)—all terminals are off when an option is not fitted.
b15
X15
X14
X13
∗5
Details of option input terminal monitor 2 (input terminal status of FR-A7AX E kit)—all terminals are off when an option is not fitted.
b15
∗6
Details of option output terminal monitor (output terminal status of FR-A7AY E kit/A7AR E kit)—all terminals are off when an option is not fitted.
b15
[Fault data]
Refer to page 279 for details of fault description
Data
Definition
Data
No fault
H00
present
H10
E.OC1
H11
E.OC2
H12
E.OC3
H20
E.OV1
H21
E.OV2
H22
E.OV3
H30
E.THT
H31
E.THM
H40
E.FIN
H52
E.ILF
220
Instruction
Name
5E DE
5E DE
5F
5F
60
60
61
61
Unit
0.01Hz/
0.001
0.01A
0.1V
0.01Hz/
0.001
0.1%
0.1V
0.1%
0.1%
0.01A
0.1V
0.01kW
RES
X12
X11
X10
X9
RA3
Definition
Data
H60
E.OLT
HC7
H70
E.BE
HC8
H80
E.GF
HD8
H81
E.LF
HD9
H90
E.OHT
HDA
HA1
E.OP1
HDB
HB0
E.PE
HF1
HB1
E.PUE
HF5
HB2
E.RET
HF6
HB3
E.PE2
HF7
HC0
E.CPU
HFD
HC5
E.IOH
Code
Parameter
Frequency setting voltage bias frequency
1
C22(922)
(built-in potentiometer)
1
Frequency setting voltage bias (built-in
C23(922)
DF
1
potentiometer)
Frequency setting voltage gain frequency
DF
1
C24(923)
(built-in potentiometer)
E0
1
Frequency setting voltage gain (built-in
E0
1
C25(923)
potentiometer)
E1
1
E1
1
Data
Input terminal status ∗2
H0F
Output terminal status ∗3
H10
H14
Cumulative energization time
H17
Actual operation time
H18
Motor load factor
H19
Cumulative power
H34
PID set point
H35
PID measured value
H36
PID deviation
H3A
Option input terminal status 1∗4
H3B
Option input terminal status 2∗5
Option output terminal status ∗6
H3C
H3D
Motor thermal load factor
H3E
Inverter thermal load factor
MRS
RH
X8
X7
X6
RA2
RA1
Y6
Fault definition display example (instruction code H74)
Definition
For read data H30A1
E.AIE
(Previous fault ...... THT)
E.USB
(Latest fault...OP1)
E.MB4
E.MB5
E.MB6
E.MB7
E.1
E.5
E.6
E.7
E.13
Name
Description
RM
RL
ABC
FU
X5
X4
X3
X2
Y5
Y4
Y3
Y2
b15
b8b7
0
0
1
1 0 0 0 0
Previous fault
(H30)
Instruction
Code
16
96
9
16
96
9
17
97
9
17
97
9
Unit
1h
1h
0.1%
1kWh
0.1%
0.1%
0.1%
0.1%
0.1%
b0
STR
STF
b0
RUN
b0
X1
X0
b0
DY
b0
Y1
Y0
b0
1
0
1
0
0
0
0
1
Latest fault
(HA1)