Mitsubishi Electric FR-A802-E Instruction Manual page 53

Separated converter type
Table of Contents

Advertisement

• NICHIFU Co., Ltd.
2
Cable gauge (mm
)
0.3 to 0.75
3.
Insert the wires into a socket.
NOTE
• When using stranded wires without a blade terminal, twist enough to avoid short circuit with a nearby terminals or wires.
• Place the flathead screwdriver vertical to the open/close button. In case the blade tip slips, it may cause an inverter damage
or injury.
 Wire removal
Pull the wire while pushing the open/close button all the way down firmly with a flathead screwdriver.
NOTE
• Pulling out the wire forcefully without pushing the open/close button all the way down may damage the terminal block.
• Use a small flathead screwdriver (tip thickness: 0.4 mm / tip width: 2.5 mm).
If a flathead screwdriver with a narrow tip is used, terminal block may be damaged.
Commercially available products (as of February 2016)
Product
Driver
• Place the flathead screwdriver vertical to the open/close button. In case the blade tip slips, it may cause an inverter damage
or injury.
 Common terminals of the control circuit (SD, PC, 5, SE)
• Terminals SD (sink logic), PC (source logic), 5, and SE are common terminals (0 V) for I/O signals. (All common terminals
are isolated from each other.) Do not earth (ground) these terminals. Avoid connecting terminal SD (sink logic) with
terminal 5, terminal PC (source logic) with terminal 5, and terminal SE with terminal 5.
• In the sink logic, terminal SD is a common terminal for the contact input terminals (STF, STR, STP (STOP), RH, RM, RL,
JOG, RT, MRS, RES, AU, and CS) and the pulse train output terminal (FM
the internal control circuit by photocoupler.
52
2. INSTALLATION AND WIRING
2.6 Control circuit
Blade terminal
Insulation cap product
product number
BT 0.75-11
VC 0.75
Open/close button
Flathead screwdriver
Model
name
SZF 0- 0,4 × 2,5
Crimping tool product
number
NH 69
When using single wire or stranded wire without crimp terminal,
push an open/close button all the way down with a flathead
screw driver, and insert the wire.
Manufacturer
Phoenix Contact Co., Ltd.
number
Open/close button
Flathead screwdriver
*1
). The open collector circuit is isolated from