About The Related Manuals - Mitsubishi Electric FR-A802-E Instruction Manual

Separated converter type
Table of Contents

Advertisement

Symbol
Name
(a)
Plug-in option connector 1
(b)
Plug-in option connector 3
(c)
Plug-in option connector 2
Voltage/current input switch
(d)
(SW2)
Ethernet communication
(e)
connector
(f)
Control circuit terminal block
(g)
PU connector
(h)
USB A connector
(i)
USB mini B connector
(j)
Front cover (upper side)
(k)
Power lamp
(l)
Alarm lamp
(m)
Charge lamp
(n)
Operation panel (FR-DU08)
(o)
Front cover (lower side)
(p)
Main circuit terminal block
(q)
Cooling fan
Switches (SW3 and SW4) for
(r)
manufacturer setting
*1
For details on how to remove the Ethernet board, refer to the Ethernet Function Manual.
*2
Refer to the Instruction Manual (Detailed).
1.3

About the related manuals

The manuals related to FR-A800 are as follows.
FR-A800 Instruction Manual (Detailed)
FR-A800-E Ethernet Function Manual
FR-CC2 Instruction Manual
FR Configurator 2 Instruction Manual
FR-A800/F800 PLC Function Programming Manual
FR-A800 Safety Stop Function Instruction Manual
16
1. INTRODUCTION
1.3 About the related manuals
Connects a plug-in option or a communication option.
The connector 2 cannot be used because the Ethernet board is installed in the
initial status. The Ethernet board must be removed to install a plug-in option to
the connector 2. (However, Ethernet communication is disabled in that case.)
Selects between voltage and current for the input via terminals 2 and 4.
Connect the Ethernet dedicated cable for connection to the network.
Connects cables for the control circuit.
Connects the operation panel (FR-DU08) or the parameter unit (FR-PU07). This
connector also enables the RS-485 communication.
Connects a USB memory device.
Connects a personal computer and enables communication with FR
Configurator2.
Remove this cover for the installation of the product, installation of a plug-in
(communication) option, switching of the voltage/current input switches, etc.
Stays ON while the power is supplied to the control circuit (R1/L11, S1/L21).
Turns ON when the protective function of the inverter is activated.
Stays ON while the power is supplied to the main circuit.
Operates and monitors the inverter.
Remove this cover for wiring.
Connects cables for the main circuit.
Cools the inverter.
Do not change the initial setting (OFF
Manual name
Description
OFF
).
ON
Manual number
IB-0600503ENG
IB-0600628ENG
IB-0600543ENG
IB-0600516ENG
IB-0600492ENG
BCN-A23228-001
Refer to page
Instruction
Manual of the
option
*1
*2
61
44
60
61
61
21
39
96
39
*2
21
38
107

Advertisement

Table of Contents
loading