Checking the Hydraulic Fluid
Service Interval: Before each use or daily
The machines reservoir is filled at the factory with
approximately 29.3 liters (7.75 U.S. gallons) of high quality
hydraulic fluid. Check the level of the hydraulic fluid
before the engine is first started and daily thereafter. The
recommended replacement fluid is:
Toro Premium All Season Hydraulic Fluid (Available in
18.9 liter (5 gallon) pails or 208 liter (55 gallon) drums. See
parts catalog or Toro distributor for part numbers.)
Alternate fluids: If the Toro fluid is not available, other fluids
may be used provided they meet all the following material
properties and industry specifications. We do not recommend
the use of synthetic fluid. Consult with your lubricant
distributor to identify a satisfactory product.
Note: Toro will not assume responsibility for damage
caused by improper substitutions, so use only products
from reputable manufacturers who will stand behind their
recommendation.
High Viscosity Index/Low Pour Point
Anti-wear Hydraulic Fluid, ISO VG 46
Material Properties:
Viscosity, ASTM D445
Viscosity Index ASTM D2270
Pour Point, ASTM D97
Industry Specifications:
Note: Many hydraulic fluids are almost colorless, making it
difficult to spot leaks. A red dye additive for the hydraulic
system oil is available in 20 ml (2/3 oz) bottles. One bottle is
sufficient for 15-22 liters (4-6 gallons ) of hydraulic oil. Order
part no. 44-2500 from your authorized Toro distributor.
1. Position the machine on a level surface, lower the
cutting units, stop the engine, and remove the key.
2. Unlatch the seat, raise it, and engage the prop rod.
3. Clean the area around the filler neck and cap of the
hydraulic tank
(Figure
filler neck.
St @ 40° C 44 to 48
St @ 100° C 7.9 to 8.5
140 to 160
-34° F to -49° F
Vickers I-286-S (Quality
Level), Vickers M-2950-S
(Quality Level), Denison
13). Remove the cap from the
1. Hydraulic tank cap
4. Remove the dipstick from the filler neck and wipe it
with a clean rag. Insert the dipstick into the filler neck;
then remove it and check the fluid level. The fluid level
should be between the two marks on the dipstick.
5. If the level is low, add the appropriate fluid to raise the
level to the upper mark.
6. Install the dipstick and cap onto the filler neck.
Checking the Planetary Gear Drive
Oil
Service Interval: Every 400 hours
Check the oil level after every 400 hours of operation or if
external leakage is noted. Use high quality SAE 85W-140 gear
lube as a replacement.
HF-0
1. With machine on level surface, position the wheel so
one check plug
and the other is at 3 o'clock position.
1. Check/drain plug (2)
2. Remove the plug at the 3 o'clock position
Oil level should be at the bottom of the check plug
hole.
26
Figure 13
(Figure
14) is at the 12 o'clock position
g019500
Figure 14
g020442
g019500
(Figure
14).