3-3-7. Flare Adjustment

Equipment: Waveform monitor (R, G, B)
Test Point: MONITOR HD SDI 1 or 2 connector
Object:
Grayscale chart
Preparations
. Setting for MSU-900
KNEE OFF button → OFF (lit)
DETAIL OFF button → OFF (lit)
MATRIX OFF button → OFF (lit)
. Shoot the grayscale chart so that the chart frame is
aligned with the underscanned monitor frame.
. Iris of the lens: A = 600 ± 20 mV
Adjustment Procedure
1. MSU menu operation:
. PAINT button → ON (lit)
. Touch panel operation
(Page 1/3) → [Flare]
Adjustment Item: R, G, B
Adjust the levels B for preferred
Specification:
level for R, G and B respectively.
F35
A
B

3-3-8. Gamma Correction Adjustment

Equipment: Waveform monitor (R, G, B)
Test Point: MONITOR HD SDI 1 or 2 connector
Object:
Grayscale chart
Preparations
. Setting for MSU-900
KNEE OFF button → OFF (lit)
GAMMA OFF button → ON (dark)
. Shoot the grayscale chart so that the chart frame is
aligned with the underscanned monitor frame.
. Iris of the lens: A = 700 ± 20 mV
A
Adjustment Procedure
1. Adjust the white balance.
WHITE button/MSU-900 → ON (lit)
2. MSU menu operation:
. PAINT button → ON (lit)
. Touch panel operation
(Page 2/3) → [Gamma]
Adjustment Item: R, G, B, Master
Specification:
Adjust the cross points B of the
grayscale for preferred level for R,
G and B respectively.
To adjust all cross points for R, G
and B simultaneously, adjust them
using the Master.
B
3-11