  • Page 1 ® DataMan 80 Series Quick Reference Guide 2023 May 04 Revision: 23.2.0.15...
  • Page 2 The safety of any system incorporating this product is the responsibility of the assembler of the system. Do not install Cognex products where they are exposed to environmental hazards such as excessive heat, dust, moisture, humidity, impact, vibration, corrosive substances, flammable substances, or static electricity.
  • Page 3 Ensure that the cable bend radius begins at least six inches from the connector. Cable shielding can be degraded or cables can be damaged or wear out faster if a service loop or bend radius is tighter than 10X the cable diameter.
  • Page 4 Symbols The following symbols indicate safety precautions and supplemental information: WARNING: This symbol indicates a hazard that could cause death, serious personal injury or electrical shock. CAUTION: This symbol indicates a hazard that could result in property damage. Note: This symbol indicates additional information about a subject. Tip: This symbol indicates suggestions and shortcuts that might not otherwise be apparent.
  • Page 5 DataMan 80 Series Accessories You can purchase the following components separately. For a list of options and accessories, contact your local Cognex sales representative. Lenses Accessory Product Number Illustration 6.2 mm lens kit that includes: DM280-LENS-62 6.2 mm optics mount 6.2 mm lens...
  • Page 6 Accessory Product Number Illustration IR 6.2 mm lens kit, 3-position with IR LED includes: DM280-KIT-IR-62 6.2 mm optics mount 6.2 mm lens (IR) Standard Infrared Light for 6.2mm (Risk Group Exempt acc. IEC62471) Manual lens cap (not assembled) Screws IR 16 mm lens kit that includes: DMA-KIT-IR-16 16 mm optics mount 16 mm lens (IR)
  • Page 7 Accessory Product Number Illustration 16 mm lens with ImageMax kit that includes: DM280-KIT-IMGMAX 16 mm optics mount 16 mm lens High Speed Liquid Lens Module (DMA-HSLL-280) High Powered red LED illumination (DM260-LED-RED- HP) (Risk Group Exempt acc. IEC62471) 2-LED half-polarized extended cover (DM260-LENS- 16CVR-P) (Risk Group Exempt acc.
  • Page 8 Illumination Product Accessory Illustration Number Red LED Light for 6.2 mm Lens (Risk Group Exempt acc. IEC 62471) DM150- LED-RED White LED Light for 6.2 mm Lens (Risk Group Exempt acc. IEC 62471) DM150- LED-WHT Blue LED Light for 6.2 mm Lens (Risk Group Exempt acc. IEC 62471) DM150- LED-BLU High-Powered Red LED Light for 16 mm Lens (Risk Group Exempt acc.
  • Page 9: Lens Covers

    Lens Covers Accessory Product Number Illustration Standard front cover. Use with a 6.2 mm lens only. DM280-CVR-62 Standard front cover, half-polarized. Use with a 6.2 mm lens only. DM280-LENS-62CVR-P DM280-LENS-62CVR-F Standard front cover, fully-polarized. Use with a 6.2 mm lens only. Extended front cover.
  • Page 10 Cables Note: Cables are sold separately. DM80- DM80- Accessory Product Number Illustration Locked IP67 USB type C cable to USB type A DMA-STCBLE- ✓ straight, 2.5 m IP65-25 Locked IP67 USB type C cable to USB type A DMA-STCBLE- ✓ straight 3.6 m IP65-36 Locked USB type C cable to USB type A angled,...
  • Page 11 DM80- DM80- Accessory Product Number Illustration Locked IP67 USB-C to DB15, right angle, 0.5 m CCB-PIO-DB15- ✓ 05RA USB I/O Cable with flying leads, 2.0 m DM-USBIO-00 ✓ RS-232 I/O Cable with flying leads, 2.5 m DM-RS232IO-00 ✓...
  • Page 12: Mounting Brackets

    Mounting Brackets Accessory Product Number Illustration Universal mounting bracket DM100-UBRK-000 Pivot mounting bracket DM100-PIVOTM-01 Tilted angle pivot bracket DMBK-DMPIVOT-00 Logistics mounting bracket and plate kit DMA-BKT-LGS Other Accessories Accessory Product Number Illustration DM80-USB DM80-PoE Sound Amplifier DM80-AMP ✓...
  • Page 13 DataMan 80 Series Systems DataMan 80-USB Systems 2DMax - PowerGrid - Omni-directional 1D Max with High Speed Hard to read Damaged 2D Resolution 1D Code Hotbars Decoding 2D codes codes DM-80L 1D Codes DM-80QL 1D Codes DM-80S 1D/2D Codes 1440 x 1080...
  • Page 14 DataMan 80-PoE Systems 2DMax - Omni- 1D Max PowerGrid Multi- High Speed Hard to directional with - Damaged Reader Resolution Decoding read 2D 1D Code Hotbars 2D codes Sync codes DM-80L 1D Codes DM-80QL 1D Codes DM-80S 1D/2D Codes 1440 x 1080 DM-80Q 1D/2D Codes...
  • Page 15 Note: Cables are sold separately. If a standard component is missing or damaged, immediately contact your Cognex Authorized Service Provider (ASP) or Cognex Technical Support. CAUTION: All cable connectors are keyed to fit the connectors on the reader. Do not force the connections or damage may occur.
  • Page 16: Reader Layout

    Reader Layout DM80-USB Layout Number Description Illumination LEDs LED aimers ACT button Power LED indicator Train status/Trigger status LED indicator Good/bad read LED indicator Communication LED indicator...
  • Page 17 Error LED indicator USB-C slot...
  • Page 18 DM80-PoE Layout Number Description Illumination LEDs LED aimers ACT button Power LED indicator Train status/Trigger status LED indicator Good/bad read LED indicator Communication LED indicator Error LED indicator Ethernet connector...
  • Page 19 Dimensions The following sections list dimensions of the reader. Note: Dimensions are in millimeters and are for reference purposes only. All specifications are for reference purposes only and can change without notice. DataMan 80-USB with 6.2 mm Lens The following image shows the dimensions of DataMan 80, equipped with 6.2 mm lens.
  • Page 20 DataMan 80-USB with 6.2 mm Lens and Sound Amplifier The following image shows the dimensions of DataMan 80, equipped with 6.2 mm lens and the Sound Amplifier attachment.
  • Page 21 DataMan80-USB with 16 mm Lens The following image shows the dimensions of DataMan80, equipped with 16 mm lens.
  • Page 22 DataMan 80-PoE with 6.2 mm Lens The following image shows the dimensions of DataMan80-PoE equipped with 6.2 mm lens.
  • Page 23 DataMan 80-PoE with 16 mm Lens The following image shows the dimensions of DataMan80-PoE equipped with 16 mm lens.
  • Page 24 Field of View and Distance This section discusses the Field of View (FoV) values for 6.2 mm and 16 mm lenses. DataMan 80 Readers with 6.2 mm Lens 6.2 mm lenses can be focused to 105 mm (short range) and to 190 mm (long range).
  • Page 25 Vertical values in mm Working distance in mm Horizontal values in mm = 40 = 38 = 29 = 65 = 58 = 44 = 105 = 90 = 68 Distances in mm 2D min. code in mil 1D min. code in mil...
  • Page 26 Long Range (Focused to 190 mm) The following table shows the Field of View (FoV) widths of the 6.2 mm lens focused to 190 mm at various distances. Vertical values in mm Working distance in mm Horizontal values in mm = 190 = 159 = 119...
  • Page 27 Distances in mm 2D min. code in mil 1D min. code in mil 1000...
  • Page 28 DataMan 80 Readers with 16 mm lens The following tables list the Field of View (FoV) widths of the 16 mm lens at various distances: Vertical values in mm Working distance in mm Horizontal values in mm = 150 = 46 = 34 = 225 = 69...
  • Page 29 Distances in mm 2D min. code in mil 1D min. code in mil 1000...
  • Page 30: Mounting The Reader

    Mounting the Reader The reader provides mounting holes for attachment to a mounting surface. CAUTION: The reader has to be grounded, either by mounting the reader to a fixture that is electrically grounded or by attaching a wire from the reader’s mounting fixture to frame ground or Earth ground.
  • Page 31: Connecting The Ethernet Cable

    Note: Mounting the reader at a slight angle (15°) reduces reflections and improves performance. Connecting the Ethernet Cable CAUTION: The Ethernet cable shield has to be grounded at the far end. Whatever this cable is plugged into (typically a switch or router) should have a grounded Ethernet connector.
  • Page 32 1. Connect the RJ-50 connector of the CCB-PIO-RJ50-2ST/RA cable to the Ethernet connector of the reader. 2. Connect the RJ-45 connector of the CCB-PIO-RJ50-2ST/RA cable to a switch, router, or PC, as applicable. Using your DataMan 80-USB Device through USB For a detailed description, see the DataMan 80 Reference Manual.
  • Page 33: Specifications

    Specifications The following sections list general specifications for the reader. DataMan80 Series Reader DataMan 80-USB DataMan 80-PoE Specification With 6.2 mm lens: 64 g With 6.2 mm lens: 99 g Weight With 16 mm lens: 97 g With 16 mm lens: 132 g USB powered: PoE Class 2 Power...
  • Page 34 DataMan 80-USB DataMan 80-PoE Specification -10–60 °C (14–140 °F) Storage Temperature Humidity <95% non-condensing DataMan 80: IP67 Environmental Note: IP67 rating applies only if you attach all blind plugs and cables properly, or install the provided connector plug. The DataMan 80-USB is compatible with 10-pin CAT5 RJ50 cables. When using off-the-shelf cables, the IP rating is based on the rating of your chosen cable.
  • Page 35 DataMan 80-USB DataMan 80-PoE Specification 1-D barcodes: Codabar, Code 39, Code 128, Code 93, Code 25, Interleaved 2 of 5, Postal Codes Codes, UPC/EAN/JAN, MSI 2-D barcodes: Data Matrix (IDMax and IDQuick: ECC 0, 50, 80, 100, 140, and 200), QR Code, microQR, PDF 417, AztecCode, DotCode, MaxiCode High-Speed Note: Only available when using the...
  • Page 36 DataMan 80 Series Reader Image Sensor Specification DataMan 80 1/3-inch CMOS, global shutter Image Sensor Diagonal size: 6.21 mm Image Sensor Properties Pixel size: 3.45 μm (H) x 3.45 μm (V) 1440 x 1080 (1.6 mp) Image Resolution (pixels) Minimum exposure: 43 μs...
  • Page 37 Wavelength DMA-KIT-IR-62 820 nm DMA-KIT-IR-16 850 nm...
  • Page 38: Regulations And Conformity

    Regulations and Conformity Note: For the most current CE and UKCA declarations and regulatory conformity information, see the Cognex support site: cognex.com/support. DataMan 80 readers have Regulatory Model numbers 50209 and 50181 and meet or exceed the requirements of all applicable standards organizations for safe operation.
  • Page 39 Safety and Regulatory Korea This device is certified for office use only and if used at home, there can be frequency interference problems. A급 기기 (업 무용 방송 통신 기자재): 이 기 기 는 업 무용(A급 ) 전 자파적 합 기기 로 서...
  • Page 40 中 国 大 陆 RoHS (Information for China RoHS Compliance) 根据 中国 大陆 《 电子信息 产品 污染 控制管 理办 法 》 ( 也称 为中 国大陆 RoHS), 以 下部 份列 出了 本产 品中可 能包 含的 有 毒有 害物 质或 元素的 名称 和含 量 。 Hazardous Substances 有...
  • Page 41: For European Community Users

    For European Community Users Cognex complies with Directive 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic equipment (WEEE). This product has required the extraction and use of natural resources for its production.