Configuration with Software

4
Configuration with Software
The configuration data of the SMP16-SFT251 are stored by the ASBIC chip on the serial EEPROM of
the board. The tables below show the default settings of the values which can be changed by the
automatic configuration software SMP16-AKO.
Note:
The configuration data must be adjusted each time a system is changed by inserting or removing a
board or module since the board or the module may not be able to be addressed otherwise.
Required settings in the "chip select channel 0 to 3" dialog fields
Channel
Setting
Address mode
Base address
Address range
Function
Sample values shown in bold type can be changed to meet the particular requirements.
1)
Default setting: Disabled
The base addresses must be whole-number multiples of the address area (e.g., for channel 0: 400h,
420h, 440h and so on).
Default settings in the "ASBIC channel settings" dialog field
Parameter
ASBIC channel
Address mode
Base address
Default settings in the "general" dialog field
Parameter
Parallel Output Port (POP)
Memory address range
22
0 (w)
1 (x)
1)
Enabled
Enabled
SMP-I/O
SMP-I/O
400 hex
420 hex
32 bytes
8 bytes
E251 function
Expanded function
Default Setting
Disabled
SMP-I/O
200 hex
Default Setting
0011 0000 bin
Includes MMIO range
2 (y)
1)
1)
Enabled
SMP-I/O
430 hex
16 bytes
Universal register,
channel 0
©Siemens AG 2003, All Rights Reserved
SMP16-SFT251
3 (z)
1)
Enabled
SMP-I/O
440 hex
16 bytes
Universal register,
channel 1
(4)J31069-D2090-U001-A1-7618