Installation and maintenance

Installation precautions

Mount Smile 11EA AS-i or Smile 11SA AS-i using two M5 bolts before attaching the M12-connector.
Warning! All the safety functions must be tested before starting up the system.

Maintenance

Warning!
The safety functions and the mechanics shall be tested regularly, at least once every year to confirm that all the
safety functions are working properly (EN 62061:2005).
In case of breakdown or damage to the product, contact the nearest ABB/Jokab Safety Service Office or reseller.
Do not try to repair the product yourself since it may accidentally cause permanent damage to the product,
impairing the safety of the device which in turn could lead to serious injury to personnel.
2TLC172094M0201, rev. B
2012-08-03
Both Smile 11EA AS-i and Smile 11SA AS-i is supplied with
30 VDC from the AS-i bus.
Recommended connection to the AS-i bus is through a flat
cable connector to M12 (see figure to the left), making it
possible to quickly and easily connect the unit to the yellow
AS-i cable.
Both Smile models can also be connected directly to the AS-i
bus using only two cables (pin-1 and 3 of the M12-connector
on the unit) according to "Connections" above.
7
www.abb.com/lowvoltage