 Parameter settings for the motor under Vector control
Using the control terminal option FR-A8TP together with the FR-A8AP enables Vector control or machine end orientation
control by switching between two encoder-equipped motors. Use Pr.862 to set the combination of the motors (first/second) and
the options (FR-A8TP/FR-A8AP).
Pr.862 Encoder option
selection
0, 1, 2
0 (initial value)
10, 11, 12
0, 1, 2
1
10, 11, 12
*1
When Pr.450 Second applied motor = "9999", the first motor is selected even if the RT signal turns ON.
Use the following parameters for the encoder input setting. The encoder input setting can be made regardless of the Pr.862
setting and first/second motor setting.
Parameter name
Encoder rotation direction
Number of encoder pulses
Encoder signal loss
detection enable/disable
selection
NOTE
• To input the RT signal, set "3" in any of Pr.178 to Pr.182, Pr.185, or Pr.189 (Input terminal function selection) to assign the
function to a terminal.
• Pr.862 setting is valid even when either the plug-in option or control terminal option is installed. For using the control
terminal option alone, the motor does not run when Pr.862 is the initial value as it is. (When the RT signal is OFF)
28
ENCODER SPECIFICATIONS AND PARAMETER SETTINGS
Pr.393 Orientation
selection
FR-A8AL
FR-A8TP
Motor end: FR-A8TP
Machine end: FR-A8AL
Parameter for control
terminal option (FR-
A8TP)
852
851
855
RT signal-ON
RT signal-OFF
(First motor)
(Second motor)
FR-A8TP
FR-A8AL
Parameter for plug-in
option (FR-A8AP)
359
369
376
Machine end
*1
orientation control
Disabled
Enabled