Download Print this page

Yamaha PX10 Service Manual page 57

Hide thumbs Also See for PX10:

Advertisement

2-2-8. DP200 V-SENSE,I-SENSE Calibration
Measurement condition
Select "Analog > CFG1 ( +14dBu ) " with Service inspection mode.
Measured mode / 8Ω MODE
Amplifi er outputs are adjusted to 250W@8Ω
Select "Analog > DP200 > V&I Calib-A, DP200 > V&I Calib-B" with Service
inspection mode.
※ Drive each channel.
2-2-9. Confirmation of DP200 V-SENSE
Measurement condition
Select "Analog > CFG1 ( +14dBu ) " with Service inspection mode.
Measured mode / 8Ω MODE
Amplifi er outputs are adjusted to 250W@8Ω
Select "Analog > DP200 > V-SENSE-A, DP200 > V-SENSE-B" with Service
inspection mode.
※ Drive each channel.
2-2-10. Confirmation of DP200 I-SENSE
Measurement condition
Select "Analog > CFG1 ( +14dBu ) " with Service inspection mode.
Measured mode / 8Ω MODE
Amplifi er outputs are adjusted to 250W@8Ω
Select "Analog > DP200 > I-SENSE-A, DP200 > I-SENSE-B" with Service
inspection mode.
※ Drive each channel.
2-2-11. Maximum Output 1 ( STEREO Mode ) ( 8Ω Mode /All channels drive )
Measurement condition
Select "Analog > CFG1 ( +14dBu ) " with Service inspection mode.
Measured mode / 8Ω MODE
Refer to the "Setups at the time of maximum output measurement"(Page 59).
※ Drive all channels.
Criteria
The test program judge 'PASS' or 'FAIL' automatically.
※ When the calibration is completed successfully, it is
outputted as PASS.
Criteria
The test program judge 'PASS' or 'FAIL' automatically.
Criteria
The test program judge 'PASS' or 'FAIL' automatically.
Criteria
All channel
PX10
More than 243Vp-p
PX8
More than 227Vp-p
PX5
More than 179Vp-p
PX3
More than 139Vp-p
PX10/PX8/PX5/PX3
57

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Px8Px5Px3