6. Electrical Wiring Diagrams

Outdoor unit
• AM080JXVHGH/EU, AM100JXVHGH/EU, AM120JXVHGH/EU, AM140KXVGGH/EU, AM180KXVGGH/EU, AM200KXVGGH/EU, AM220KXVGGH/EU,
AM080JXVAGH/EU, AM100JXVAGH/EU, AM120JXVAGH/EU, AM140KXVAGH/EU, AM200KXVAGH/EU, AM220KXVAGH/EU
INV PBA1
Printed circuit board (inverter1)
INV PBA2
Printed circuit board (inverter2)
EMI PBA1
Printed circuit board (emi1)
EMI PBA2
Printed circuit board (emi2)
FAN PBA
Printed circuit board (fan motor)
MAIN PBA
Printed circuit board (main)
HUB PBA
Printed circuit board (hub)
COMM PBA
Printed circuit board (communication)
COMP1
Motor (compressor1)
COMP2
Motor (compressor2)
FAN1
Motor (fan1)
FAN2
Motor (fan2)
EVI V/V 1
Solenode valve (EVI1)
EVI V/V 2
Solenode valve (EVI2)
EVI EEV
Electronic expansion valve (EVI)
NOTE
• This wiring diagram applies only to the outdoor unit.
• Colors blk: black, red: red, blu: blue, wht: white, yel: yellow, brn: brown, sky: skyblue
• When operating, don't shortcircuit the protection device (High Pressure switch)
• For connection wiring indoor-outdoor transmission F1-F2, outdoor_outdoor transmission OF1-OF2, refer to
the installation manual.
Protective earth(screw),
104
EEV1
Electronic expansion valve 1
EEV2
Electronic expansion valve 2
EVI-OUT(10K)
Thermistor (EVI-out_10kohm)
EVI-IN(10K)
Thermistor (EVI-in_10kohm)
SUCTION1(10K)
Thermistor (Suction Temp.1_10Kohm)
SUCTION2(10K)
Thermistor (Suction Temp.2_10Kohm)
SNOW SENSOR
SNOW SENSOR
OIL-COMP1
Oil-Sensor (Compressor1)
OIL-COMP2
Oil-Sensor (Compressor2)
OUT(10K)
Thermistor (Ambient Temp._10Kohm)
COND(10K)
Thermistor (Cond Out Temp._10Kohm)
TOP1(200K)
Thermistor (Compressor Top 1_200Kohm)
TOP2(200K)
Thermistor (Compressor Top 2_200Kohm)
DIS1(200K)
Thermistor (Discharge Temp.1_200Kohm)
DIS2(200K)
Thermistor (Discharge Temp.2_200Kohm)
: connector,
: The wire quantity
LIQUID(10K)
Thermistor (Liquid Tube Temp._10Kohm)
HOTGAS1 V/V
Solenoid valve (Hot Gas Bypass1)
EVI BYPASS V/V
Solenoid valve (EVI BYPASS)
RETURN V/V
Solenoid valve (Accumulator Oil Return)
4WAY V/V
Solenoid valve (4 Way valve)
CCH1
Crank Case Heater (Compressor1)
CCH2
Crank Case Heater (Compressor2)
MAIN COOLING
Solenoid valve (Main cooling)
HOTGAS2 V/V
Solenoid valve (Hot Gas Bypass2)
OD EEV V/V
Solenoid valve (Outdoor EEV)
F101
FUSE (Inverter PBA)
690V/T40A
FUSE (EMI PBA)
MODE CHANGE
Connector (Remote switching cool/heat selector)
EXT CON
Connector (Output EXT CON)
ERROR/COMP EXT
Connector (Output ERROR/COMP EXT CON)