Write_EPC_Mem

The "Write_EPC_Mem" instruction overwrites the EPC memory of the RF600 transponder
starting at address 4. The length of the EPC memory to be overwritten is specified by the
"LEN_DATA" parameter.
Figure 4-19 Instruction "Write_EPC_Mem"
Table 4- 32 Explanation for the instruction "Write_EPC_Mem"
Parameter
LEN_DATA
LEN_ID
EPCID_UID
IDENT_DATA
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04
Data type
Default values
INT
0x00
SINT
0x00
SINT[62]
0
SINT[10]
0
Configuring the instructions
4.5 Programming instructions
Description
Length of the EPC memory to be
overwritten (1 ... 62 bytes)
Default value: 0x00 ≙ unspecified
Length of the EPC-ID/UID
single tag access (RF600)
Buffer for up to 62 bytes EPC-ID, 8
bytes UID or 4 bytes handle ID.
2 - 62-byte EPC-ID is entered at
the start of the buffer (length is
set by "LEN_ID")
8-byte UID is entered at the start
of the buffer ("LEN_ID = 8")
Data buffer with the EPC memory
data to be overwritten.
Note:
When necessary, an array of any size
can be transferred to this parameter.
Note that the array must be ≥ 10
bytes long (e.g. "SINT[12400]").