Page 1
CP415 Installation and Operation Manual English ABB, 1SBC159107M0201 2008-09...
Page 2
Document number: ABB, 1SBC159107M0201 Please read the entire installation manual prior to installing and using this equipment. Only qualified personnel may install, operate or repair this equipment. ABB is not responsible for modified, altered or renovated equipment. Because the equipment has a wide range of applications, users must acquire the appropriate knowledge to use the equipment properly in their specific applications.
Self Test ..................15 System Menu ................16 Bench and Function Tests ............17 Setting Communication Parameters ........... 17 Touch Screen Calibration............18 Downloading an Application ............. 19 Uploading an Application ............20 Copying an Application ............. 21 Passwords................... 22 ABB, 1SBC159107M0201...
– The supplier neither guarantees that the operator terminal is suitable for your particular application, nor assumes responsibility for your product design, in- stallation or operation. ABB, 1SBC159107M0201...
Page 6
Dismantling and Scrapping – The operator terminal or parts thereof shall be recycled according to local regulations. – The following components contain substances that might be hazardous to health and the environment: lithium battery, electrolytic capacitor and display. ABB, 1SBC159107M0201...
Installation Installation Package Contents The following parts are found in the box: – Operator terminal CP415 – 4 installation fasteners – Power connector (connected to the 24 V DC power input) – Installation and operation manual (1SBC159107M0201) ABB, 1SBC159107M0201...
Product Specifications Product Specifications Parameter CP415 Front panel, W x H x D 96 x 96 x 7 mm Mounting depth 40.6 mm Cut-out dimensions 89.3 x 89.3 mm Front panel seal IP 65/NEMA 4X (indoor use only) Weight 0.21 kg...
Product Specifications Description of Parts Front Fixture mounting holes Power lamp Communication lamp Display Back DC power input DIP switches (1-10) COM1: RS232/RS422/RS485 ABB, 1SBC159107M0201...
3. The operator terminal is to be installed within the angle of 0 to 135 shown below. Grounding To make sure that the operator terminal works properly and to prevent it from radiating radio frequency noise, it must be connected to the earth ground. ABB, 1SBC159107M0201...
Product Specifications Power Supply and Wiring CP415 must use the power supply with 24 V DC and the power consumption is 4 W. Warning: To avoid an electrical shock, be sure to switch off the power before connecting the communication/download cable to the operator terminal.
The default user level is set to 9 if the operator terminal requires no password to start its operation. COM1 Port For RS485, this switch has to be set ON. For RS422, this switch has to be set OFF. SW10 Reserved ABB, 1SBC159107M0201...
Make sure that the connection is in accordance with the setting of the dip switches, for example RS485 corresponds to SW9 = ON. See section 4 Dip Switches. Function RS422 TX+ (RS485+) RS232 RXD RS232 TXD RS422 RX+ Signal ground RS422 TX- (RS485-) RS232 RTS RS232 CTS RS422 RX- ABB, 1SBC159107M0201...
After downloading again, all items should pass the self-test. Note: When using the operator terminal for the first time, remember to reset the real time clock (RTC). ABB, 1SBC159107M0201...
+ and - to set the value of the field. Copy Copies application data to another CP415. Calibrates the touch panel and adjusts LCD contrast. See also section 6.5 Touch Screen Calibration.
Bench and Function Tests Set dip switches SW3 and SW4 = OFF to be able to run the bench and function tests for the CP415. Turn on the operator terminal to display the following screen: The bench test performs an overall hardware test, and the function test lets the user select which item to be tested.
2. Follow the route on the screen. 3. Touch the square on the center of the screen to complete the task. Note: When using the Set command all RAM data will be cleared. See also section 6.2 System Menu. ABB, 1SBC159107M0201...
Operation Downloading an Application Connect the RS232 port on the PC to the COM1 port on the CP415 using a TK401 cable. The connection can also be made according to the illustration be- low: CP415 CP415 IPC485 or RS485 COM1...
*.V6F file. Thus a source file can serve the purposes of maintenance and modification. Note: When uploading for the first time, make sure to first run the application once, or else the upload function will not work. ABB, 1SBC159107M0201...
Operation Copying an Application To copy an application from one CP415 to another CP415, select Copy from the system menu. Set the dip switch SW7 = ON and connect the two operator terminals with a download cable. After the self-test, the system menu will be dis- played on the screen.
2, then the operator terminal will set the user level to 2. User level 1 has the highest privilege and User level 9 has the lowest. Note: Only users of User Level 1 has the right of access to the password table. ABB, 1SBC159107M0201...
Page 23
When selecting Copy in the system menu or File/Upload Application in CP400Soft, the operator terminal will prompt for a password. The user will need to enter the correct password to copy an application from one CP415 to another. Note that setting this password is different from the passwords set in Scenarios 1-3.
Page 24
ABB FRANCE ABB STOTZ-KONTAKT GmbH Division Automation Products Po Box 10 16 80 Export Department 69006 Heidelberg 10 rue Ampère Germany 69685 Chassieu Tel. : +49 (0) 6221/701-1190 France Fax. : +49 (0) 6221/701-1333 Tel. : +33 (0) 4 72 22 17 22 Fax.