Phasor measurement unit RES670
Version 2.2
Table 185. Analog system selection
Analog system
When more than one TRM is selected, the connector type on both TRMs must be the same (A compression or B ring lug).
Slot position (front view/rear view)
No Transformer input module included
TRM 12I 1A, 50/60Hz, compression terminals
TRM 12I 5A, 50/60Hz, compression terminals
TRM 9I 1A + 3U 110/220V, 50/60Hz, compression terminals
TRM 9I 5A + 3U 110/220V, 50/60Hz, compression terminals
TRM 5I 1A + 4I 5A + 3U 110/220V, 50/60Hz, compression terminals
TRM 6I 1A + 6U 110/220V, 50/60Hz, compression terminals
TRM 6I 5A + 6U 110/220V, 50/60Hz, compression terminals
TRM 3IM 1A + 4IP 1A + 5U 110/220V, 50/60Hz, compression terminals
TRM 3IM 5A + 4IP 5A + 5U 110/220V, 50/60Hz, compression terminals
TRM 12I 1A, 50/60Hz, ring lug terminals
TRM 12I 5A, 50/60Hz, ring lug terminals
TRM 9I 1A + 3U 110/220V, 50/60Hz, ring lug terminals
TRM 9IM 1A + 3U 110/220V, 50/60Hz, ring lug terminals
TRM 9I 5A + 3U 110/220V, 50/60Hz, ring lug terminals
TRM 5I 1A + 4I 5A + 3U 110/220V, 50/60Hz, ring lug terminals
TRM 6I 1A + 6U 110/220V, 50/60Hz, ring lug terminals
TRM 6IM 1A + 6U 110/220V, 50/60Hz, ring lug terminals
TRM 6I 5A + 6U 110/220V, 50/60Hz, ring lug terminals
TRM 3IM 1A + 4IP 1A + 5U 110/220V, 50/60Hz, ring lug terminals
TRM 3IM 5A + 4IP 5A + 5U 110/220V, 50/60Hz, ring lug terminals
1)
Only valid if IEC 61850-9-2 Process bus communication is selected.
Table 186. Maximum quantity of I/O modules, with compression terminals
When ordering I/O modules, observe the maximum quantities according to the tables below.
Note: Standard order of location for I/O modules is BIM-BOM-SOM-IOM-MIM from left to right as seen from the rear side of the IED, but can also
be freely placed.
Note: The maximum quantity of I/O modules depends on the type of connection terminals.
Case sizes
BIM
1/1 x 19" rack casing,
14
one (1) TRM
1/1 x 19" rack casing,
11
two (2) TRM
3/4 x 19" rack casing,
8
one (1) TRM
3/4 x 19" rack casing,
5
two (2) TRM
1/2 x 19" rack casing,
3
one (1) TRM
*) Including a combination of maximum four modules of type BOM or SOM and six modules of type MIM.
**) Max 2 SOM possible
106
IOM
BOM/
MIM
Maximum in case
SOM
6
4
6
14 *)
6
4
6
11 *)
6
4
6
8 *)
5
4
5
5 *)
3
3
1
3 **)
© 2017 - 2022 Hitachi Energy. All rights reserved
Ordering no
Selection
X0
X0
1MRK002247-CG
A1
A1
1MRK002247-CH
A2
A2
1MRK002247-BG
A3
A3
1MRK002247-BH
A4
A4
1MRK002247-BK
A5
A5
1MRK002247-AG
A6
A6
1MRK002247-AH
A7
A7
1MRK002247-EA
A17
A17
1MRK002247-EB
A18
A18
1MRK002247-CC
B1
B1
1MRK002247-CD
B2
B2
1MRK002247-BC
B3
B3
1MRK002247-BL
B21
B21
1MRK002247-BD
B4
B4
1MRK002247-BF
B5
B5
1MRK002247-AC
B6
B6
1MRK002247-AZ
B22
B22
1MRK002247-AD
B7
B7
1MRK002247-EC
B17
B17
1MRK002247-ED
B18
B18
Selected
1MRK 511 410-BEN P