Advertisement
Optional Accessory: Wall Cover-Up Plate F61-2663, 6 3/4" W x 4 1/2" H
Thermostat Applications | Maximum Stages Heat/Cool |
Conventional Gas, Oil, Electric (mV and 24V), Heat Only, Cool Only or Heat/ Cool Systems | 1/1 |
Heat Pump (air source or geothermal) with no Aux. Heat | 1/1 |
MERCURY NOTICE: This product does not contain mercury. However, this product may replace a product that contains mercury. Mercury and products containing mercury must not be discarded in household trash. Refer to www.thermostat-recycle.org for information on disposing of products containing mercury.
Electrical Rating:
Battery Power: mV to 30 VAC, NEC Class II, 50/60 Hz
Input-Hardwire: 20 to 30 VAC, NEC Class II, 50/60 Hz
Terminal Load: 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range: 45° to 99°F (7° to 37°C)
Rated Differentials: | Fast | Med | Slow |
Heat (@ 6°F/ Hr) | 0.5°F | 0.75°F | 1.9°F |
Cool (@ 6°F/ Hr) | 0.9°F | 1.2°F | 1.7°F |
Operating Ambient: 32°F to +105°F (0° to +41°C)
Display Temperature Range: 32°F to +99°F (0 to 37°C)
Operating Humidity: 90% non-condensing max
Shipping Temperature Range: -20°F to + 150°F (-29° to +65°C)
Thermostat Dimensions: 3-3/4" H x 6" W x 1-1/8" D
Refer to equipment manufacturer's instructions for specific system wiring information. After wiring, see INSTALLER MENU for proper thermostat configuration. Wiring table shown are for typical systems and describe the thermostat terminal functions.
Terminal Designations | Terminal Function |
RC* | Power for Cooling |
RH* | Power for Heating |
O/B | Changeover Terminal-Energized in Heat (B) or Cool (O) for Heat Pump or Damper Systems |
Y** | Cooling Relay |
G | Fan Relay |
W** | Heating Relay |
C | Common wire for 24V (optional with batteries) |
*When both RC and RH wires are present, cut RC/RH jumper (see next page).
**For heat pump systems, add a jumper wire to connect terminals Y and W
Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard.
Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will burn out thermostat and could cause personal injury and/or property damage.
To prevent electrical shock and/or equipment damage, disconnect electrical power to system, at main fuse or circuit breaker box, until installation is complete.
*Battery Location
Premium AA alkaline batteries are required when C-wire is not available. When C-wire is available, the batteries provide a back-up source of power (this will maintain the clock in the event of a power outage).
To prevent changes that may affect system performance, this thermostat has an INSTALLER'S MENU and an USER MENU. The INSTALLER'S MENU provides access to every option, while the USER MENU provides access to items that will not affect system performance. To access the INSTALLER'S MENU press the Menu button for 8 seconds. The display will show item 30 in the table below. Use Next and Back to navigate through menu items. Press or
to change a menu setting.
Installer's Menu # (Hold Menu 8 Seconds) | Description | Default Setting (flashing icons) | Settings (Press ![]() ![]() |
30 ![]() | Heat Cycle Rate (how often the heat will turn on) | MEd | SLO – slow MEd – medium FAS – fast |
35 ![]() | Cool Cycle Rate (how often the cooling will turn on) | MEd | SLO – slow MEd – medium FAS – fast |
50 ![]() | Compressor Lockout (protects the compressor from short cycling) | OFF | On – 5 minute display OFF – no delay |
65 | Maximum Heat Limit (maximum set point for heat mode) | 99 | 47 to 99 |
66 | Minimum Cool Limit (minimum set point for cool mode) | 45 | 45 to 97 |
79 | Fahrenheit or Celsius | °F | °F – Fahrenheit °C – Celsius |
81 | Temperature Display Adjustment (adjust the displayed "Room Temperature") | 0 | -5 to +5 |
83 ![]() | Continuous Display Light (keep the backlight always on – "C" wire required) | OFF | On – always on OFF – momentarily |
99 ![]() | Keypad Lock (prevent unwanted changes to the thermostat) | OFF | On – disable buttons OFF – all buttons are active |
Turn on power to the system.
Fan Operation
If your system does not have a G terminal connection, skip to Heating System.
Heating System
Cooling System
Note: If Starting Soon is shown on the display, the compressor lockout feature is operating. There will be up to a 5 minute delay before the compressor turns on.(see INSTALLER MENU, item 50)
To prevent compressor and/or property damage, if the outdoor temperature is below 50°F, DO NOT operate the cooling system.
Do not allow the compressor to run unless the compressor oil heaters have been operational for 6 hours and the system has not been operational for at least 5 minutes.
THERMOSTAT BUTTONS AND SWITCHES | THE DISPLAY |
1.) Fan Switch | 7.) Thermostat is protecting the equipment from short cycling (5-minute delay) |
2.) System Switch | 8.) Indicates that the system is running in cool or heat |
3.) Backlight Button (located on the top of the thermostat | 9.) Battery status indicator |
4.) Raises Temperature Setting | 10.) Low battery indicator * |
5.) Access Menu Options | 11.) Temperature setpoint |
6.) Lowers Temperature Setting | 12.) Appears when the keypad is locked (to prevent unwanted changes) |
13.) Next (Menu button) is used to navigate within a menu | |
14.) SEE TROUBLESHOOTING |
* Whenever " " appears in the display, new premium brand AA alkaline batteries should be installed. If the house will be unoccupied for an extended period and either "
"or "
" is displayed, install new batteries before leaving.
To customize thermostat settings, press and hold the Menu button for ½ second from the home screen. Use the Next button to advance through menu items. Press or
to change the setting.
User's Menu # (Press Menu button and release) | Description | Default Setting (flashing icons) | Settings (Press ▲ or ▼) |
01 ![]() | Continuous Display Light (keep the backlight always on – "C" wire required) | OFF | On – always on OFF – momentarily |
Symptom | Possible Cause | Corrective Action |
No Heat/ (common problem) |
|
|
No Heat |
| Verify thermostat and system wires are securely attached. Diagnostic: Set System Switch to Heat and raise the setpoint above room temperature. Within five minutes the thermostat should make a soft click sound and "Heat On" should appear on display. This sound indicates the thermostat is operating properly. If the thermostat does not click, try the reset operation listed below. If the thermostat does not click after being reset, contact your heating and cooling service person or place of purchase for a replacement. If the thermostat clicks, contact the furnace manufacturer or a service person to verify the heating system is operating correctly. |
No Cool |
| Verify thermostat and system wires are securely attached. Diagnostic: Set System Switch to Cool and lower setpoint below room temperature. Same procedures as diagnostic for "No Heat" condition except set the thermostat to Cool and lower the setpoint below the room temperature. There may be up to a five minute delay before the thermostat clicks in Cooling if the compressor lock-out option is selected in the installer menu. (see INSTALLER MENU, item 50) |
Heat, Cool or Fan Runs Constantly | Possible short in wiring, thermostat, heat, cool or fan system | Check each wire connection to verify they are not shorted or touching other wires. Try resetting the thermostat. If the condition persists contact your HVAC service person. |
Thermostat Display & Thermometer Disagree | Thermostat display requires adjustment | Display can be adjusted +/-5°. See User Menu item 04 |
Furnace (Air Conditioner) Cycles Too Fast or Slow(narrow or wide temperature swing) | The location of the thermostat and/or the size of the Heating System may be influencing the cycle rate | Digital thermostats provide precise control and cycle faster than older mechanical models. The system turns on and off more frequently but runs for a shorter time. If you would like to increase cycle time, choose SLO for slow cycle in the Installer menu. (Reference menu items 30 & 35) If an acceptable cycle rate is not achieved, contact your HVAC service person. |
"Call for Service" icon appears on displayed |
|
|
Resetting the Thermostat or Thermostat Settings
If the thermostat has good batteries, but has a blank display or does not respond to key presses, the thermostat should be reset by removing the batteries for 2minutes. This reset will not change the menu settings. If the condition persists after reinstalling the batteries, replace the thermostat.To conveniently reset only the user settings back to factory defaults, press Menu and Backlight buttons at the same time and hold until the display goes blank and resets.
This product contains a chemical known to the state of California to cause cancer and birth defects and other reproductive harm.
HOMEOWNER HELP LINE: 1-800-284-2925
Emerson and White-Rodgers are trademarks of Emerson Electric Co.
©2020 Emerson Electric Co.
All rights reserved.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Emerson (Non-Programmable) Thermostat 1F83C-11NP Manual
Advertisement
Need help?
Do you have a question about the 1F83C-11NP and is the answer not in the manual?
Questions and answers