Summary of Contents for xFusion Digital Technologies FusionServer 1288H V6
Page 1
FusionServer 1288H V6 Server Technical White Paper Issue Date 2022-06-25 xFusion Digital Technologies Co., Ltd.
Page 2
Notice In this document, "xFusion" is used to refer to "xFusion Digital Technologies Co., Ltd." for concise description and easy understanding, which does not mean that "xFusion" may have any other meaning. Any "xFusion" mentioned or described hereof may not be understood as any meaning other than "xFusion Digital Technologies Co., Ltd.", and xFusion Digital Technology Co., Ltd.
Technical White Paper About This Document About This Document Purpose This document describes the FusionServer 1288H V6 rack server in terms of features, structure, specifications, and component hardware and software compatibility. Intended Audience This document is intended for pre-sales engineers.
Page 6
FusionServer 1288H V6 Server Technical White Paper About This Document Change History Issue Release Date Change Description 2022-06-25 ⚫ Added a figure that shows how to measure dimensions. ⚫ Upgrades the standards of CE, UKCA, and CCC certifications in the chapter 10 Certifications.
Technical White Paper 1 Overview Overview FusionServer 1288H V6 (1288H V6) is a new-generation 1U 2-socket rack server designed for Internet, Internet Data Center (IDC), cloud computing, enterprise, and telecom applications. The 1288H V6 is ideal for IT core services, cloud computing, virtualization, high-performance computing, distributed storage, big data processing, enterprise or telecom service applications, and other complex workloads.
FusionServer 1288H V6 Server Technical White Paper 2 Features Features Performance and Scalability ⚫ ® ® Powered by the third-generation Intel Xeon Scalable Ice Lake processors, the server provides up to 40 cores, 3.6 GHz frequency, a 60 MB L3 cache, and up to three 11.2 GT/s UPI links between the processors, which deliver supreme processing performance.
Page 9
FusionServer 1288H V6 Server Technical White Paper 2 Features ⚫ Flexible drive configurations meet a variety of business requirements and ensure high elasticity and scalability of storage resources. ⚫ The use of all solid-state drives (SSDs) is supported. An SSD supports up to 100 times more I/O operations per second (IOPS) than a typical hard disk drive (HDD).
Page 10
FusionServer 1288H V6 Server Technical White Paper 2 Features ⚫ The Intel Converged Boot Guard & Trusted Execution Technology (Intel CBnT) prevents malicious software attacks based on hardware, prevents the firmware from being maliciously modified, and prevents the execution of unauthorized boot blocks. It also allows applications to run in their own independent space without being affected by other software running in the system, thereby enhancing security.
FusionServer 1288H V6 Server Technical White Paper 3 Physical Structure Physical Structure Figure 3-1 Physical structure of a server with 8 x 2.5" drives (example) I/O module 1 I/O module 2 Chassis PSUs Air duct Fan module brackets Fan modules...
Page 12
FusionServer 1288H V6 Server Technical White Paper 3 Physical Structure BMC card OCP 3.0 network adapters Screw-in RAID controller TPM/TCM card Memory modules 2022-06-25...
FusionServer 1288H V6 Server Technical White Paper 4 Logical Structure Logical Structure Figure 4-1 Logical Structure ⚫ ® ® The server supports one or two third-generation Intel Xeon Scalable Ice Lake processors. ⚫ The server supports up to 32 memory modules.
Page 14
FusionServer 1288H V6 Server Technical White Paper 4 Logical Structure ⚫ The BMC management chip integrated on the mainboard supports a video graphic array (VGA) port, a management network port, and a serial port. 2022-06-25...
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description ⚫ 8 x 2.5" Drive Configuration Figure 5-2 Front view Drive (Optional) Built-in DVD drive Label with SN ⚫ 10 x 2.5" drive configuration Figure 5-3 Front view Drive Slide-out label plate (with an SN label) 5.1.2 Indicators and Buttons...
Page 17
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description indicator indicator Power button/indicator UID button/indicator iBMC direct connect management port indicator ⚫ 8 x 2.5" drive configuration Figure 5-5 Indicators and buttons on the front panel Power button/indicator UID button/indicator...
Page 18
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Indicator and Button Descriptions Table 5-1 Description of indicators and buttons on the front panel Indicator and Silkscreen Description Button ⚫ Fault diagnosis ---: The device is operating properly. ⚫...
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Silkscreen Indicator and Description Button The UID button/indicator helps identify and locate a button/indicator device. UID indicator: ⚫ Off: The device is not being located. ⚫ Blinking or steady blue: The device is being located.
Page 20
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Figure 5-7 Ports on the front panel iBMC direct connect USB 3.0 port management port VGA port ⚫ 8 x 2.5" drive configuration Figure 5-8 Ports on the front panel iBMC direct connect USB 3.0 port...
Page 21
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Port Description Table 5-2 Ports on the front panel Port Type Quantity Description Note VGA port DB15 Used to connect a display terminal, such as a monitor or KVM. iBMC direct...
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description 5.2 Rear Panel 5.2.1 Appearance Figure 5-10 Rear view I/O module 1 I/O module 2 PSU 1 Power supply 2 (Optional) FlexIO card 2 (Optional) FlexIO card 1 NOTE NOTE...
Page 23
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description indicator for the management for the management network network port port Serial port indicators PSU indicators NOTE Reserved and unavailable currently. UID indicator Indicator Description Table 5-3 Indicators on the rear panel...
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Silkscreen Indicator Description UID indicator The UID indicator helps identify and locate a device. ⚫ Off: The device is not being located. ⚫ Blinking or steady blue: The device is being located.
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Port Type Quantity Description NOTE The port uses 3-wire serial communication interface, and the default baud rate is 115,200 bit/s. VGA port DB15 Used to connect a display terminal, such as a monitor or KVM.
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Figure 5-13 Processor positions 5.4 Memory 5.4.1 DDR4 Memory 5.4.1.1 Memory ID You can determine the memory module properties based on the label attached to the memory module. Figure 5-14 Memory identifier...
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Channel Memory Slot DIMM031(L) E (primary) DIMM040(E) DIMM041(M) F (primary) DIMM050(F) DIMM051(N) G (primary) DIMM060(G) DIMM061(O) H (primary) DIMM070(H) DIMM071(P) CPU2 A (primary) DIMM100(A) DIMM101(I) B (primary) DIMM110(B) DIMM111(J) C (primary)
Page 29
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description ⚫ A server must use DDR4 memory modules of the same part number (P/N code), and the memory speed is the minimum value of the following items: ⚫ Memory speed supported by a CPU ⚫...
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Parameter Specifications server Maximum DDR4 1024 2048 4096 8192 memory capacity of the server (GB) Actual 1DPC 3200 3200 3200 3200 2933 rate 2DPC 3200 3200 3200 3200 2933 (MT/s) ⚫...
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description 5.4.1.5 Memory Installation Positions A server supports a maximum of 32 DDR4 memory modules. To maximize performance, balance the total memory capacity between the installed processors and to load the channels similarly whenever possible.
Page 32
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Figure 5-16 DDR4 memory module installation guidelines (1 processor) 2022-06-25...
Page 33
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Figure 5-17 DDR4 memory module installation guidelines (2 processors) 2022-06-25...
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Description Example Component Intel Optane Persistent Memory 8089-A2-2008-00002461 Model NMB1XXD512GPSU4 Capacity (GB) ⚫ ⚫ ⚫ SN QR code 8089-A2-2008-00002461 5.4.2.2 Memory Subsystem Architecture The server provides 32 memory slots. Each processor integrates eight memory channels, and each memory channel supports only one PMem module.
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Channel Memory Slot DIMM101(I) B (primary) DIMM110(B) DIMM111(J) C (primary) DIMM120(C) DIMM121(K) D (primary) DIMM130(D) DIMM131(L) E (primary) DIMM140(E) DIMM141(M) F (primary) DIMM150(F) DIMM151(N) G (primary) DIMM160(G) DIMM161(O) H (primary)
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Total memory capacity = Total capacity of all PMem modules (The DDR4 memory modules are used as the cache and therefore are not calculated as memory capacity.) For details about the AD and MM modes, see FusionServer PMem 200 User Guide.
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description On the same server, it is recommended that the ratio of the DDR4 memory capacity to the PMem capacity be 1:4 to 1:16. 5.4.2.5 Memory Installation Positions A server supports a maximum of 16 PMem modules. The PMem modules must be used with the DDR4 memory modules.
Page 39
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Figure 5-20 PMem module installation guidelines (1 processor) Figure 5-21 PMem module installation guidelines (2 processors) 2022-06-25...
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description 5.4.2.6 Memory Protection Technologies The following memory protection technologies are supported: ⚫ PMem module Error Detection and Correction ⚫ PMem module Device Failure Recovery (SDDC) ⚫ PMem module Package Sparing (DDDC) ⚫...
Page 41
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Drive Management Mode ⚫ ⚫ 8 x 2.5" drive Front drive: 8 x pass-through 2.5" configuration 1 − Slots 0 to 7 support only SATA drives.
Page 42
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Drive Management Mode ⚫ ⚫ 10 x 2.5" drive Front drive: 10 x SAS/SATA pass-through 2.5" drive: 1 x configuration 4 screw-in RAID − Slots 0 to 5...
The drive numbers identified by the RAID controller card vary depending on the cabling of the RAID controller card. The drive numbers identified by the RAID controller card in this section are provided based on the default cabling described in "Internal Cabling" in FusionServer 1288H V6 Server Maintenance and Service Guide. ⚫...
Page 44
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified by the iBMC ⚫ 4 x 3.5" drive pass-through configuration Corresponds to 4 x 3.5" drive pass-through configuration 2 in 5.5.1 Drive Configurations . Figure 5-23 Slot Numbers Table 5-11 Slot numbers Drive No.
Page 45
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller ⚫ 8 x 2.5" drive pass-through configuration Corresponds to 8 x 2.5" drive pass-through configuration 1 in 5.5.1 Drive Configurations .
Page 46
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Table 5-14 Slot numbers Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller ⚫ 10 x 2.5" drive pass-through configuration Corresponds to 10 x 2.5" drive pass-through configuration 1 in 5.5.1 Drive Configurations .
Page 47
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller ⚫ 10 x 2.5" drive pass-through configuration Corresponds to 10 x 2.5" drive pass-through configuration 2 in 5.5.1 Drive Configurations .
Page 48
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Figure 5-29 Slot Numbers Table 5-17 Slot numbers Drive No. Drive Number Identified by the iBMC ⚫ 10 x 2.5" drive pass-through configuration Corresponds to 10 x 2.5" drive pass-through configuration 4 and 10 x 2.5" drive pass-through configuration 5 in 5.5.1 Drive Configurations .
Page 49
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller Note Note Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can manage the drive and allocate a number to the drive.
Page 50
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Figure 5-32 Slot Numbers Table 5-20 Slot numbers Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller Note Note Note Note Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can manage the drive and allocate a number to the drive.
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description 5.5.3 Drive Indicators SAS/SATA Drive Indicators Figure 5-33 SAS/SATA drive indicators Table 5-21 SAS/SATA drive indicators Activity Indicator Fault Indicator Description (Green) (Yellow) The drive is not in position. Steady on The drive is detected.
Page 52
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Table 5-22 NVMe drive indicators (VMD enabled) Activity Indicator Fault Indicator Description (Green) (Yellow) The NVMe drive is not detected. Steady on The NVMe drive is detected and operating properly.
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Figure 5-35 M.2 FRU indicators Table 5-24 M.2 FRU indicators M.2 FRU Active M.2 FRU Fault Description Indicator (Green) Indicator (Yellow) The M.2 FRU is not detected. Steady on The M.2 FRU is inactive.
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description ⚫ Contact your local sales representative or see "Search Parts" in the Compatibility Checker to determine the components to be used. ⚫ For details about the OCP 3.0 network adapter, see the documents of each OCP 3.0 network adapter.
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Device Slot Standa ctor Port (B/D/F Slot Width Size (B/D/F Width ⚫ The maximum power supply of each PCIe slot is 75 W. 5.8 PSUs ⚫...
Page 58
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Figure 5-40 Positions of fan modules 2022-06-25...
Page 60
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description 2 x USB 3.0 ports (USB3.0 Rear VGA port (VGA CONN/J88) CONN/J60) Serial port (COM/J6020) BMC management network port (BMC_GE /J6019) BMC management board OCP 3.0 network adapter 1 connector (OCP1...
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description BP/J27) a: Reserved and unavailable currently. 5.10.2 Drive Backplane Front Drive Backplane ⚫ 4 x 3.5" drive pass-through backplane Configure this backplane in 4 x 3.5" drive pass-through configuration 1, 4 x 3.5" drive pass-through configuration 2, and 4 x 3.5"...
Page 62
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description Backplane power connector Mini-SAS HD connector (HDD POWER/J24) (PORT A/J28) Backplane signal cable connector (HDD_BP/J1) ⚫ 10 x 2.5" drive pass-through backplane Configure this backplane in 10 x 2.5" drive pass-through configuration 1, 10 x 2.5" drive pass-through configuration 2, 10 x 2.5"...
Page 63
FusionServer 1288H V6 Server Technical White Paper 5 Hardware Description LP slimline 4 connector Mini-SAS HD connector (SLIM C/ (PORT A/J6) SLIM_4/PORT_2A/J5) LP slimline 3 connector LP slimline 5 connector (SLIM D/ (SLIM E/ SLIM_3/PORT_1B/J4) SLIM_5/PORT_1A/J17) Backplane low-speed signal Backplane power connector...
FusionServer 1288H V6 Server Technical White Paper 6 Product Specifications Product Specifications 6.1 Technical Specifications 6.2 Environmental Specifications 6.3 Physical Specifications 6.1 Technical Specifications Table 6-1 Technical specifications Component Specifications Form factor 1U rack server ® Chipset Intel C621A Processor Supports one or two processors.
Page 65
FusionServer 1288H V6 Server Technical White Paper 6 Product Specifications Component Specifications − RDIMM and LRDIMM support − Max. 3200 MT/s memory speed − The DDR4 memory modules of different types (RDIMM and LRDIMM) and specifications (capacity, bit width, rank, and height) cannot be used together.
Page 66
FusionServer 1288H V6 Server Technical White Paper 6 Product Specifications Component Specifications The NVMe drives support: ⚫ Before using the VMD function, contact technical support engineers of the OS vendor to check whether the OS supports the VMD function. If yes, check whether the VMD driver needs to be manually installed and check the installation method.
Page 67
FusionServer 1288H V6 Server Technical White Paper 6 Product Specifications Component Specifications − Two USB 3.0 ports − One DB15 VGA port NOTE The front panel of a server with 10 x 2.5" drives provides only one USB Type-C iBMC direct connect management port and one USB 3.0 port.
FusionServer 1288H V6 Server Technical White Paper 6 Product Specifications 6.2 Environmental Specifications Table 6-2 Environmental specifications Category Specifications ⚫ Temperature Operating temperature: 5° C to 45° C (41° F to 113° F) (ASHRAE Classes A1 to A4 compliant) Storage temperature (within three months): –30° C to +60° C ⚫...
FusionServer 1288H V6 Server Technical White Paper 6 Product Specifications Category Specifications of ISO 14664-1 Class 8. ⚫ There is no explosive, conductive, magnetic, or corrosive dust in the equipment room. NOTE It is recommended that the particulate pollutants in the equipment room be monitored by a professional organization.
Page 70
FusionServer 1288H V6 Server Technical White Paper 6 Product Specifications Item Description Figure 6-1 Physical dimensions (example: 2.5" drive chassis) NOTE ⚫ See Figure 6-1 for methods in measuring physical dimensions of the chassis. ⚫ Methods measuring 3.5" and 2.5" drive chassis are the same. The 2.5"...
Page 71
FusionServer 1288H V6 Server Technical White Paper 6 Product Specifications Item Description Energy consumption The power consumption parameters vary with hardware configurations (including the configurations complying with EU ErP). Use the Power Calculator to obtain specific information. 2022-06-25...
FusionServer 1288H V6 Server Technical White Paper 7 Software and Hardware Compatibility Software and Hardware Compatibility Use the Compatibility Checker to obtain information about the operating systems and hardware supported. ⚫ If incompatible components are used, the device may be abnormal. This fault is beyond the scope of technical support and warranty.
FusionServer 1288H V6 Server Technical White Paper 8 Safety Instructions Safety Instructions 8.1 Security 8.2 Maintenance and Warranty 8.1 Security General Statement ⚫ Comply with local laws and regulations when installing devices. These Safety Instructions are only a supplement. ⚫...
Page 74
FusionServer 1288H V6 Server Technical White Paper 8 Safety Instructions Figure 8-1 Safety work wear ⚫ Before touching a device, wear ESD clothing and gloves (or wrist strap), and remove any conductive objects (such as watches and jewelry). Figure 8-2 shows conductive objects that must be removed before you touch a device.
Page 75
FusionServer 1288H V6 Server Technical White Paper 8 Safety Instructions Figure 8-3 Wearing an ESD wrist strap ⚫ Exercise caution when using tools. ⚫ If the installation position of a device is higher than the shoulders of the installation personnel, use a vehicle such as a lift to facilitate installation. Prevent the device from falling down and causing personal injury or damage to the device.
FusionServer 1288H V6 Server Technical White Paper 8 Safety Instructions ⚫ Transport each device in its original packaging. ⚫ If the original packaging is unavailable, package heavy, bulky parts (such as chassis and blades) and fragile parts (such as PCIe cards and optical modules) separately.
FusionServer 1288H V6 Server Technical White Paper 9 System Management System Management This product integrates the new-generation Intelligent Baseboard Management Controller (iBMC), which complies with Intelligent Platform Management Interface 2.0 (IPMI 2.0) specifications and provides reliable hardware monitoring and management.
Page 78
FusionServer 1288H V6 Server Technical White Paper 9 System Management ⚫ System maintenance interface − The virtual KVM and virtual media functions facilitate remote maintenance. − The iBMC supports out-of-band RAID monitoring and configuration to improve RAID configuration efficiency and management capabilities.
FusionServer 1288H V6 Server Technical White Paper 10 Certifications Certifications Country/Region Certification Standards Europe WEEE 2012/19/EU Europe REACH EC NO. 1907/2006 Europe Safety: EN 62368-1:2014+A11:2017 EMC: EN 55032:2015+A11:2020 CISPR 32:2015+A1:2019 EN IEC 61000-3-2:2019+A1:2021 EN 61000-3-3:2013+A1:2019 EN 55035:2017+A11:2020 CISPR 35:2016 EN 55024:2010+A1:2015 CISPR 24:2010+A1:2015 ETSI EN 300 386 V1.6.1:2012...
Page 80
FusionServer 1288H V6 Server Technical White Paper 10 Certifications Country/Region Certification Standards EN 55032:2015+A11:2020 CISPR 32:2015+A1:2019 EN IEC 61000-3-2:2019+A1:2021 EN 61000-3-3:2013+A1:2019 EN 55035:2017+A11:2020 CISPR 35:2016 EN 55024:2010+A1:2015 CISPR 24:2010+A1:2015 ETSI EN 300 386 V1.6.1:2012 ETSI EN 300 386 V2.1.1:2016 RoHS:...
FusionServer 1288H V6 Server Technical White Paper A Appendix Appendix A.1 Chassis Label The label information and location are for reference only. For details, see the actual product. A.1.1 On the Front Top Figure A-1 Chassis head label Nameplate Certificate...
Page 82
FusionServer 1288H V6 Server Technical White Paper A Appendix device. A.1.1.1 Nameplate Figure A-2 Nameplate example Table A-1 Nameplate description Description Server Model For details, seeA.4 Nameplate . Device names Power Supply Requirements Vendor Information Authentication ID A.1.1.2 Certificate Figure A-3 Sample certificate of conformity...
Page 83
FusionServer 1288H V6 Server Technical White Paper A Appendix Table A-2 Certificate of conformity description Description Order NOTE For details, see Figure A-4 and Table A-3. QC inspector Production date No. Barcode Figure A-4 Sample certificate number Table A-3 Certificate No. Description Description "P", fixed...
Page 84
FusionServer 1288H V6 Server Technical White Paper A Appendix Description ⚫ Letters A to H indicate 10 to 17:00. ⚫ Letters J to N indicate 18 to 22:00. ⚫ Letters P to Q indicate 23 to 24:00. Serial number (2 digits) Manufacturing serial number (5 digits).
Page 85
FusionServer 1288H V6 Server Technical White Paper A Appendix A.1.2 Chassis Tail Label Figure A-6 Chassis tail label For details about the warning label, see Server Security Information. A.1.3 Chassis Internal Label Figure A-7 Chassis internal label ⚫ The quick guide is located on the inside of the chassis cover. It describes how to remove the mainboard components, important components of the chassis, precautions, and QR codes of technical resources.
Page 86
FusionServer 1288H V6 Server Technical White Paper A Appendix Figure A-8 SN example Table A-5 SN description Description ESN ID (two characters), which can only be 21. Material ID (eight characters), that is, the processing code. Vendor code (two characters), that is, the code of the processing place.
Page 87
FusionServer 1288H V6 Server Technical White Paper A Appendix Configuration Maximum Maximum Maximum Maximum Operating Operating Operating Operating Temperature Temperature Temperature Temperature 30° C (86° F) 35° C (95° F) 40° C (104° F) 45° C (113° F) configuration 51N/8358/8 M.2) are not...
Page 88
FusionServer 1288H V6 Server Technical White Paper A Appendix Configuration Maximum Maximum Maximum Maximum Operating Operating Operating Operating Temperature Temperature Temperature Temperature 30° C (86° F) 35° C (95° F) 40° C (104° F) 45° C (113° F) drive supported.
Page 89
FusionServer 1288H V6 Server Technical White Paper A Appendix Configuration Maximum Maximum Maximum Maximum Operating Operating Operating Operating Temperature Temperature Temperature Temperature 30° C (86° F) 35° C (95° F) 40° C (104° F) 45° C (113° F) 10 x 2.5-inch ⚫...
Page 90
FusionServer 1288H V6 Server Technical White Paper A Appendix Configuration Maximum Maximum Maximum Maximum Operating Operating Operating Operating Temperature Temperature Temperature Temperature 30° C (86° F) 35° C (95° F) 40° C (104° F) 45° C (113° F) supported. 10 x 2.5-inch ⚫...
Page 91
FusionServer 1288H V6 Server Technical White Paper A Appendix ⚫ When a single fan is faulty, the system performance may be affected. ⚫ When memory modules of 256 GB per module or larger or 6342/6348/6346/6354/8352V/8352S/8352Y/8358P/8351N/8358/8360Y/8368/8380 processors are configured, rear GPU cards, rear drives (including HDDs, SSDs, and M.2), IB cards, or OCP 3.0 network adapters with 25Gbit/s rate or higher are not supported.
Page 92
FusionServer 1288H V6 Server Technical White Paper A Appendix Sensor Description Component N indicates the CPU number. The value is 1 or 2. CPUN MEM Temp CPU memory module Memory module temperature corresponding to CPU N N indicates the CPU number.
Page 93
FusionServer 1288H V6 Server Technical White Paper A Appendix Sensor Description Component PSN VIN PSU N input voltage PSU N N indicates the PSU number. The value is 1 or 2. Disks Temp Maximum drive temperature Drive RAID Temp Temperature of the RAID...
Page 94
FusionServer 1288H V6 Server Technical White Paper A Appendix Sensor Description Component health status UID Button UID button status Mainboard PwrOk Sig. Drop Voltage dip status Mainboard PwrOn TimeOut Power-on timeout Mainboard PwrCap Status Power capping status Mainboard HDD Backplane...
Page 95
FusionServer 1288H V6 Server Technical White Paper A Appendix Sensor Description Component PCIe RAID$ Temp Temperature of the PCIe PCIe RAID controller card RAID controller card M2 Temp(PCIe$) Maximum temperature of all PCIe RAID controller card M.2 drives of the RAID...
Page 96
FusionServer 1288H V6 Server Technical White Paper A Appendix Sensor Description Component PCIe$ Temp PCIe card chip temperature PCIe card PCIe$ Card BBU BBU status of the PCIe PCIe RAID controller card RAID controller card GPU$ Power GPU card power...
Page 97
FusionServer 1288H V6 Server Technical White Paper A Appendix Sensor Description Component OAMPort2_$ Link Network port OAM link status 2022-06-25...
FusionServer 1288H V6 Server Technical White Paper B Glossary Glossary B.1 A-E The baseboard management controller (BMC) complies with the Intelligent Platform Management Interface (IPMI). It collects, processes, and stores sensor signals, and monitors the operating status of components. The BMC provides the...
Page 99
FusionServer 1288H V6 Server Technical White Paper B Glossary hot swap Replacing or adding components without stopping or shutting down the system. B.3 K-O A hardware device that provides public video, keyboard and mouse (KVM). B.4 P-T panel An external component (including but not limited to ejector levers, indicators, and ports) on the front or rear of the server.
Page 100
FusionServer 1288H V6 Server Technical White Paper B Glossary system event log Event records stored in the system used for subsequent fault (SEL) diagnosis and system recovery. B.5 U-Z A unit defined in International Electrotechnical Commission (IEC) 60297-1 to measure the height of a cabinet, chassis, or subrack.
FusionServer 1288H V6 Server Technical White Paper C Acronyms and Abbreviations Acronyms and Abbreviations C.1 A-E alternating current Advanced Encryption Standard New Instruction Set Address Resolution Protocol Advanced Vector Extensions backup battery unit BIOS Basic Input/Output System baseboard management controller...
Page 102
FusionServer 1288H V6 Server Technical White Paper C Acronyms and Abbreviations direct current DDR4 Double Data Rate 4 DDDC double device data correction DEMT Dynamic Energy Management Technology DIMM dual in-line memory module DRAM dynamic random-access memory digital video disc...
Page 103
FusionServer 1288H V6 Server Technical White Paper C Acronyms and Abbreviations high availability hard disk drive high-performance computing HTTP Hypertext Transfer Protocol HTTPS Hypertext Transfer Protocol Secure iBMC intelligent baseboard management controller Industry Canada ICMP Internet Control Message Protocol Internet Data Center...
Page 104
FusionServer 1288H V6 Server Technical White Paper C Acronyms and Abbreviations LRDIMM load-reduced dual in-line memory module light emitting diode LAN on motherboard media access control module management controller next business day NC-SI Network Controller Sideband Interface Open Compute Project C.4 P-T...
Page 105
FusionServer 1288H V6 Server Technical White Paper C Acronyms and Abbreviations reliability, availability and serviceability RDIMM registered dual in-line memory module REACH Registration Evaluation and Authorization of Chemicals RJ45 registered jack 45 RoHS Restriction of the Use of Certain Hazardous Substances in...
Page 106
FusionServer 1288H V6 Server Technical White Paper C Acronyms and Abbreviations Trusted Execution Technology TransFlash module TFTP Trivial File Transfer Protocol TCP offload engine trusted platform module C.5 U-Z UDIMM unbuffered dual in-line memory module UEFI Unified Extensible Firmware Interface unit identification light Underwriter Laboratories Inc.
Need help?
Do you have a question about the FusionServer 1288H V6 and is the answer not in the manual?