FusionServer 2288H V6 Server
Technical White Paper
Issue
04
Date
2022-06-25
xFusion Digital Technologies Co., Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FusionServer 2288H V6 and is the answer not in the manual?

Questions and answers

Summary of Contents for xFusion Digital Technologies FusionServer 2288H V6

  • Page 1 FusionServer 2288H V6 Server Technical White Paper Issue Date 2022-06-25 xFusion Digital Technologies Co., Ltd.
  • Page 2 Notice In this document, "xFusion" is used to refer to "xFusion Digital Technologies Co., Ltd." for concise description and easy understanding, which does not mean that "xFusion" may have any other meaning. Any "xFusion" mentioned or described hereof may not be understood as any meaning other than "xFusion Digital Technologies Co., Ltd.", and xFusion Digital Technology Co., Ltd.
  • Page 3: Table Of Contents

    FusionServer 2288H V6 Server Technical White Paper Contents Contents About This Document ........................vii 1 Overview ............................9 2 Features ............................11 3 Physical Structure ........................14 3.1 2288H V6-32DIMM ..............................14 3.2 2288H V6-16DIMM ..............................15 4 Logical Structure ......................... 17 4.1 2288H V6-32DIMM ..............................
  • Page 4 5.1.4.2.3 Memory Compatibility ............................48 5.1.4.2.4 DIMM Installation Rules ........................... 49 5.1.4.2.5 Memory Installation Positions ........................... 50 5.1.4.2.6 Memory Protection Technologies ........................51 5.1.5 Storage ..................................52 5.1.5.1 Drive Configurations ............................52 5.1.5.1.1 8 x 2.5" Drive Pass-through configuration......................52 5.1.5.1.2 12 x 2.5"...
  • Page 5 FusionServer 2288H V6 Server Technical White Paper Contents 5.2.4.1.5 Memory Installation Positions ......................... 152 5.2.4.1.6 Memory Protection Technologies ........................153 5.2.5 Storage ................................... 154 5.2.5.1 Drive Configurations ............................154 5.2.5.1.1 8 x 2.5" drive pass-through configuration ......................154 5.2.5.1.2 12 x 3.5" drive pass-through configuration ...................... 157 5.2.5.1.3 12 x 3.5"...
  • Page 6 C Acronyms and Abbreviations ....................257 2022-06-25...
  • Page 7: About This Document

    Technical White Paper About This Document About This Document Purpose This document describes the FusionServer 2288H V6 rack server in terms of features, structure, specifications, and component hardware and software compatibility. Intended Audience This document is intended for pre-sales engineers.
  • Page 8 FusionServer 2288H V6 Server Technical White Paper About This Document Change History Issue Release Date Change Description 2022-06-25 ⚫ Added a figure that shows how to measure dimensions. ⚫ Upgrades the standards of CE, UKCA, and CCC certifications in the chapter 10 Certifications.
  • Page 9: Overview

    Technical White Paper 1 Overview Overview FusionServer 2288H V6 (2288H V6) is a new-generation 2U 2-socket rack server designed for Internet, Internet Data Center (IDC), cloud computing, enterprise, and telecom applications. The 2288H V6 is ideal for IT core services, cloud computing, virtualization, high-performance computing, distributed storage, big data processing, enterprise or telecom service applications, and other complex workloads.
  • Page 10 FusionServer 2288H V6 Server Technical White Paper 1 Overview Figure 1-2 2288H V6-16DIMM with 12 x 3.5" drives (example) 2022-06-25...
  • Page 11: Features

    FusionServer 2288H V6 Server Technical White Paper 2 Features Features Performance and Scalability ⚫ ® ® Powered by the third-generation Intel Xeon Scalable Ice Lake processors, the server provides up to 40 cores, 3.6 GHz frequency, a 60 MB L3 cache, and up to three 11.2 GT/s UPI links between the processors, which deliver supreme processing performance.
  • Page 12 FusionServer 2288H V6 Server Technical White Paper 2 Features ⚫ 2288H V6-16DIMM servers support a maximum of 16 DDR4 ECC 3200 MT/s DIMMs. The DDR4 ECC DIMMs support registered DIMMs (RDIMM) and load-reduced DIMMs (LRDIMMs), which provide high speed and availability. A server supports a maximum memory capacity of 2048 GB and a maximum memory bandwidth of 400 GB/s in theory.
  • Page 13 FusionServer 2288H V6 Server Technical White Paper 2 Features ⚫ The NC-SI feature allows a network port to serve as a management port and a service port. The NC-SI feature is disabled by default and can be enabled through the iBMC or BIOS.
  • Page 14: Physical Structure

    FusionServer 2288H V6 Server Technical White Paper 3 Physical Structure Physical Structure 3.1 2288H V6-32DIMM 3.2 2288H V6-16DIMM 3.1 2288H V6-32DIMM Figure 3-1 Physical structure of a server with 12 x 3.5" drives (example) I/O module 1 I/O module 2...
  • Page 15: 2288H V6-16Dimm

    FusionServer 2288H V6 Server Technical White Paper 3 Physical Structure Air duct Intrusion sensor NOTE The air duct cannot be installed on a server with built-in drives. Front-drive backplane Left mounting ear plate Fan module brackets Fan module Front drive...
  • Page 16 FusionServer 2288H V6 Server Technical White Paper 3 Physical Structure Chassis I/O module 3 Supercapacitor holder Air duct Intrusion sensor NOTE The air duct cannot be installed on a server with built-in drives. Front-drive backplane Left mounting ear plate Fan module brackets...
  • Page 17: Logical Structure

    FusionServer 2288H V6 Server Technical White Paper 4 Logical Structure Logical Structure 4.1 2288H V6-32DIMM 4.2 2288H V6-16DIMM 4.1 2288H V6-32DIMM Figure 4-1 Logical Structure ⚫ ® ® The server supports one or two third-generation Intel Xeon Scalable Ice Lake processors.
  • Page 18: 2288H V6-16Dimm

    FusionServer 2288H V6 Server Technical White Paper 4 Logical Structure ⚫ The CPUs (processors) interconnect with each other through three UPI links at a speed of up to 11.2 GT/s. ⚫ The PCIe riser card connects to the processors through PCIe buses to provide ease of expandability and connection.
  • Page 19 FusionServer 2288H V6 Server Technical White Paper 4 Logical Structure ⚫ The screw-in RAID controller card on the mainboard connects to CPU 1 through PCIe buses, and connects to the drive backplane through SAS signal cables. A variety of drive backplanes are provided to support different local storage configurations.
  • Page 20: Hardware Description

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Hardware Description 5.1 2288H V6-32DIMM 5.2 2288H V6-16DIMM 5.1 2288H V6-32DIMM 5.1.1 Front Panel 5.1.1.1 Appearance ⚫ 8 x 2.5" Drive Configuration Figure 5-1 Front view Drive (Optional) Built-in DVD...
  • Page 21 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-2 Front view Drive Slide-out label plate (with an SN label) ⚫ 12 x 3.5" drive configuration Figure 5-3 Front view Drive Slide-out label plate (with an SN label) ⚫...
  • Page 22: Indicators And Buttons

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description ⚫ 24 x 2.5" drive configuration Figure 5-5 Front view Drive Slide-out label plate (with an SN label) ⚫ 25 x 2.5" drive configuration Figure 5-6 Front view Drive Slide-out label plate (with an SN label) 5.1.1.2 Indicators and Buttons...
  • Page 23 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-7 Indicators and buttons on the front panel Fault diagnosis LED Power button/indicator Health status indicator UID button/indicator FlexIO card 1 presence FlexIO card 2 presence indicator indicator iBMC direct connect management port indicator ⚫...
  • Page 24 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-9 Indicators and buttons on the front panel Fault diagnosis LED Power button/indicator Health status indicator UID button/indicator FlexIO card 1 presence FlexIO card 2 presence indicator indicator iBMC direct connect management port indicator ⚫...
  • Page 25 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-11 Indicators and buttons on the front panel Fault diagnosis LED Power button/indicator Health status indicator UID button/indicator FlexIO card 1 presence FlexIO card 2 presence indicator indicator iBMC direct connect management port indicator ⚫...
  • Page 26 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Silkscreen Indicator and Description Button ⚫ Fault diagnosis ---: The device is operating properly. ⚫ Error code: A component is faulty. For details about error codes, see the FusionServer Rack Server iBMC Alarm Handling.
  • Page 27: Ports

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Silkscreen Indicator and Description Button FlexIO card Indicates whether the FlexIO card is detected. presence ⚫ Off: The FlexIO card is not detected. indicator ⚫ Blinking green at 0.5 Hz: The FlexIO card is detected but is not powered on.
  • Page 28 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description management port VGA port ⚫ 12 x 2.5" drive configuration (4 x SAS/SATA + 8 x NVMe) Figure 5-14 Ports on the front panel USB 3.0 port iBMC direct connect...
  • Page 29 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description USB 3.0 port iBMC direct connect management port VGA port ⚫ 24 x 2.5" drive configuration Figure 5-17 Ports on the front panel USB 3.0 port iBMC direct connect management port VGA port ⚫...
  • Page 30: Rear Panel

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Port Type Quantity Description iBMC direct USB Type-C Used to connect to a local PC connect through a USB Type-C cable to NOTE management monitor and manage the system. The USB 2.0...
  • Page 31 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-19 Rear view I/O module 1 I/O module 2 I/O module 3 Power supply 2 PSU 1 (Optional) FlexIO card 2 NOTE The FlexIO card slot supports only OCP 3.0 network adapters.
  • Page 32 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Slot2 Slot3 Slot6 Slot7 PSU 2 Power supply unit (PSU) 1 (Optional) FlexIO card 2 (Optional) Slot 9 NOTE The FlexIO card slot supports only OCP 3.0 network adapters. (Optional) FlexIO card 1...
  • Page 33: Indicators And Buttons

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description ⚫ For details about the OCP 3.0 network adapter, see 5.1.6.1 OCP 3.0 Network Adapters . ⚫ The figure is for reference only. The actual configuration may vary. 5.1.2.2 Indicators and Buttons Indicator Positions ⚫...
  • Page 34 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description network port the management network port Serial port indicator UID indicator NOTE Reserved and unavailable currently. PSU indicator ⚫ Server with 11 standard PCIe cards on the rear panel Figure 5-23 Indicators on the rear panel...
  • Page 35: Interface

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Silkscreen Indicator Description UID indicator The UID indicator helps identify and locate a device. ⚫ Off: The device is not being located. ⚫ Blinking or steady blue: The device is being located.
  • Page 36 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-24 Ports on the rear panel Management network port Serial port VGA port USB 3.0 port Socket for PSU 1 Socket for PSU 2 ⚫ Server with four GPUs on the rear panel...
  • Page 37 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Management network port Serial port VGA port USB 3.0 port Socket for PSU 1 Socket for PSU 2 Port Description Table 5-4 Ports on the rear panel Port Type Quantity...
  • Page 38: Processors

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Port Type Quantity Description PSUs as required. NOTE When determining the PSUs, ensure that the rated power of the PSUs is greater than that of the server. 5.1.3 Processors ⚫...
  • Page 39: Memory Subsystem Architecture

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-28 Memory identifier Description Example Capacity ⚫ 16 GB ⚫ 32 GB ⚫ 64 GB ⚫ 128 GB ⚫ 256 GB Number of ranks ⚫ 1R: single-rank ⚫ 2R: dual-rank ⚫...
  • Page 40 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Table 5-5 Memory channels Channel Memory Slot CPU 1 A (primary) DIMM000(A) DIMM001(I) B (primary) DIMM010(B) DIMM011(J) C (primary) DIMM020(C) DIMM021(K) D (primary) DIMM030(D) DIMM031(L) E (primary) DIMM040(E) DIMM041(M) F (primary)
  • Page 41: Memory Compatibility

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Channel Memory Slot H (primary) DIMM170(H) DIMM171(P) 5.1.4.1.3 Memory Compatibility Observe the following rules when configuring DDR4 memory modules: ⚫ A server must use DDR4 memory modules of the same part number (P/N code), and the memory speed is the minimum value of the following items: ⚫...
  • Page 42: Dimm Installation Rules

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Table 5-6 DDR4 memory specifications Parameter Specifications Capacity per DDR4 memory module (GB) Type RDIMM RDIMM RDIMM LRDIMM RDIMM Rated speed (MT/s) 3200 3200 3200 3200 2933 Operating voltage (V)
  • Page 43: Memory Installation Positions

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description − Each processor supports four integrated memory controllers (IMCs), and each IMC has two channels for installing memory modules. The installed memory modules must be identical in size and organization.
  • Page 44 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-30 DDR4 memory module installation guidelines (1 processor) 2022-06-25...
  • Page 45 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-31 DDR4 memory module installation guidelines (2 processors) 2022-06-25...
  • Page 46: Memory Protection Technologies

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description 5.1.4.1.6 Memory Protection Technologies The following memory protection technologies are supported: ⚫ ⚫ Memory Mirroring ⚫ Memory Single Device Data Correction (SDDC) ⚫ Failed DIMM Isolation ⚫ Memory Thermal Throttling ⚫...
  • Page 47: Memory Subsystem Architecture

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Description Example Component Intel Optane Persistent Memory 8089-A2-2008-00002461 Model NMB1XXD512GPSU4 Capacity (GB) ⚫ ⚫ ⚫ SN QR code 8089-A2-2008-00002461 5.1.4.2.2 Memory Subsystem Architecture The server provides 32 memory slots. Each processor integrates eight memory channels, and each memory channel supports only one PMem module.
  • Page 48: Memory Compatibility

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Channel Memory Slot DIMM101(I) B (primary) DIMM110(B) DIMM111(J) C (primary) DIMM120(C) DIMM121(K) D (primary) DIMM130(D) DIMM131(L) E (primary) DIMM140(E) DIMM141(M) F (primary) DIMM150(F) DIMM151(N) G (primary) DIMM160(G) DIMM161(O) H (primary)
  • Page 49: Dimm Installation Rules

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description For details about the AD and MM modes, see FusionServer PMem 200 User Guide. ⚫ For details about the capacity type of a single memory module, see "Search Parts" in the Compatibility Checker.
  • Page 50: Memory Installation Positions

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description 5.1.4.2.5 Memory Installation Positions A server supports a maximum of 16 PMem modules. The PMem modules must be used with the DDR4 memory modules. Observe the memory module installation rules when configuring memory modules. For...
  • Page 51: Memory Protection Technologies

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-35 PMem module installation guidelines (2 processors) 5.1.4.2.6 Memory Protection Technologies The following memory protection technologies are supported: ⚫ PMem module Error Detection and Correction ⚫ PMem module Device Failure Recovery (SDDC) ⚫...
  • Page 52: Storage

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description 5.1.5 Storage 5.1.5.1 Drive Configurations 5.1.5.1.1 8 x 2.5" Drive Pass-through configuration Drive configuration Table 5-9 Drive configuration Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode 8 x 2.5" drive ⚫...
  • Page 53 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode only SAS/SAT A drives. ⚫ ⚫ 8 x 2.5" drive Front drive: 1 x PCIe pass-through + RAID 8 x 2.5"...
  • Page 54 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-36 Slot numbers Table 5-10 Slot numbers Drive No. Drive Number Identified by the iBMC ⚫ Drive slot numbers of 8 x 2.5" drive pass-through configuration 2 and 8 x 2.5" drive...
  • Page 55 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-37 Slot numbers Table 5-11 Slot numbers Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller Card ⚫ Drive slot numbers of 8 x 2.5" drive pass-through + 11 x PCIe card configuration 1 and 8 x 2.5"...
  • Page 56 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-38 Slot numbers Table 5-12 Slot numbers Drive No. Drive Number Identified by the iBMC ⚫ Drive slot numbers of 8 x 2.5" drive pass-through + 11 x PCIe card configuration 2, 8 x 2.5"...
  • Page 57: 12 X 2.5" Drive Pass-Through Configuration

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the RAID Controller by the iBMC Card 5.1.5.1.2 12 x 2.5" Drive Pass-Through Configuration Drive configuration Table 5-14 Drive configuration Configuration...
  • Page 58 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode ⚫ ⚫ 12 x 2.5" drive Front drive: SAS/SATA pass-through 12 x 2.5" drive: 1 x configuration 3 PCIe RAID −...
  • Page 59 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Slot numbers ⚫ Drive slot numbers of 12 x 2.5" drive pass-through configuration 1 (4 x SATA + 8 x NVMe) and 12 x 2.5" drive (4 x SATA + 8 x NVMe) + 4 x GPU configuration 1 in Table 5-14.
  • Page 60: 12 X 3.5" Drive Pass-Through Configuration

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Table 5-16 Slot numbers Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller 5.1.5.1.3 12 x 3.5" Drive Pass-through configuration Drive configuration Table 5-17 Drive configuration...
  • Page 61 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode A drives. A drives. drive: CPU ⚫ I/O module 2: 2 x 3.5" − Slots 42 and 43 support only SAS/SAT A drives.
  • Page 62 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode support support card only only ⚫ NVMe SAS/SAT SAS/SAT drive: CPU A drives. A drives. ⚫ I/O module 3: 4 x 2.5"...
  • Page 63 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode support only NVMe drives 12 x 3.5" drive ⚫ Front drive: ⚫ I/O module ⚫ SAS/SATA pass-through 12 x 3.5"...
  • Page 64 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-42 Slot numbers Table 5-18 Slot numbers Drive No. Drive Number Identified by the iBMC ⚫ Drive slot numbers of 12 x 3.5" drive pass-through configuration 2 in Table 5-17...
  • Page 65 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-43 Drive slot numbers (3.5" drives in I/O module 1 and I/O module 2) Figure 5-44 Drive slot numbers (2.5" drives in I/O module 1 and 3.5" drives in I/O module Table 5-19 Slot numbers Drive No.
  • Page 66 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller ⚫ Drive slot numbers of 12 x 3.5" drive pass-through configuration 3 in Table 5-17 Figure 5-45 Drive slot numbers (2.5"...
  • Page 67 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-46 Drive slot numbers (2.5" drives in I/O module 1 and I/O module 2) Table 5-20 Slot numbers Drive Number Identified Drive Number Identified Drive No. by the iBMC...
  • Page 68 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description ⚫ Drive slot numbers of 12 x 3.5" drive pass-through configuration 4 in Table 5-17 Figure 5-47 Drive slot numbers Table 5-21 Slot numbers Drive No. Drive Number Identified Drive Number Identified...
  • Page 69 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description ⚫ Drive slot numbers of 12 x 3.5" drive pass-through configuration 1 (4 x NVMe) in Table 5-17 Figure 5-48 Slot numbers Table 5-22 Slot numbers Drive No. Drive Number Identified by the iBMC...
  • Page 70 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description ⚫ Drive slot numbers of 12 x 3.5" drive pass-through configuration 2 (4 x NVMe) in Table 5-17 Figure 5-49 Drive slot numbers (3.5" drives in I/O module 1 and I/O module 2) Figure 5-50 Drive slot numbers (2.5"...
  • Page 71 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller Note Note Note Note Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can manage the drive and allocate a number to the drive.
  • Page 72 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-52 Drive slot numbers (2.5" drives in I/O module 1 and I/O module 2) Table 5-24 Slot numbers Drive Number Identified Drive Number Identified Drive No. by the iBMC...
  • Page 73: 12 X 3.5" Drive Exp Configuration

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can manage the drive and allocate a number to the drive.
  • Page 74 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode ⚫ I/O module A drives. 2: 2 x 2.5"/2 x 3.5" − Slots 42 and 43 support only SAS/SAT A drives.
  • Page 75 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode support support card only only ⚫ NVMe SAS/SAT SAS/SAT drive: CPU A drives. A drives. ⚫ I/O module 2: 2 x 2.5"/2 x 3.5"...
  • Page 76 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode slots 0 to ⚫ NVMe drive: CPU ⚫ a: The server with CPU 2 supports NVMe drives, but the server with a single CPU does not support NVMe drives.
  • Page 77 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-54 Drive slot numbers (2.5" drives in I/O module 1 and 3.5" drives in I/O module Table 5-26 Slot numbers Drive No. Drive Number Identified Drive Number Identified by the iBMC...
  • Page 78 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller Note Note Note Note ⚫ Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can manage the drive and allocate a number to the drive.
  • Page 79 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-55 Drive slot numbers (2.5" drives in I/O module 1 and 3.5" drives in I/O module 2022-06-25...
  • Page 80 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-56 Drive slot numbers (2.5" drives in I/O module 1 and I/O module 2) Table 5-27 Slot numbers Drive No. Drive Number Identified Drive Number Identified by the iBMC...
  • Page 81 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller Note Note Note Note ⚫ Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can manage the drive and allocate a number to the drive.
  • Page 82 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-58 Drive slot numbers (2.5" drives in I/O module 1 and I/O module 2) Table 5-28 Slot numbers Drive Number Identified Drive Number Identified Drive No. by the iBMC...
  • Page 83 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description ⚫ Drive slot numbers of 12 x 3.5" drive EXP configuration 5 (dual RAID controller cards) in Table 5-25 Figure 5-59 Slot numbers Table 5-29 Slot numbers Drive No. Drive Number Identified...
  • Page 84: 20 X 2.5" Drive Pass-Through Configuration

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller 5.1.5.1.5 20 x 2.5" Drive Pass-Through Configuration Drive configuration Table 5-30 Drive configuration Configuration Front Drive...
  • Page 85 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode 16 x NVMe) only support card SAS/SAT only ⚫ NVMe A drives. SAS/SAT drive: CPU A drives. − Slots 4 to...
  • Page 86 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified by the iBMC ⚫ Drive slot numbers of 20 x 2.5" drive pass-through configuration 2 (4 x SAS/SATA + 16 x NVMe) and 20 x 2.5" drive pass-through configuration 3 (4 x SAS/SATA + 16 x NVMe) in Table 5-30.
  • Page 87: 24 X 2.5" Drive Pass-Through Configuration

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller 5.1.5.1.6 24 x 2.5" Drive Pass-through configuration Drive configuration Table 5-33 Drive configuration Configuration Front Drive...
  • Page 88 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode 3 support drive: CPU only SATA/N drives. − Slots 4 to support only NVMe drives. ⚫ ⚫ ⚫ 24 x 2.5" drive...
  • Page 89 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode drives in slots 8 to − PCIe RAID controlle r card manages drives in slots 16 to 23. ⚫ NVMe drive: CPU ⚫...
  • Page 90 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified by the iBMC ⚫ Drive slot numbers of 24 x 2.5" NVMe configuration 2 in Table 5-33 Figure 5-63 Slot numbers 2022-06-25...
  • Page 91 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Table 5-35 Slot numbers Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller Note Note Note Note Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can manage the drive and allocate a number to the drive.
  • Page 92 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description ⚫ Drive slot numbers of 24 x 2.5" drive pass-through configuration (three RAID controller cards) in Table 5-33 Figure 5-64 Slot numbers Table 5-36 Slot numbers Drive No. Drive Number Identified...
  • Page 93: 25 X 2.5" Drive Exp Configuration

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller 5.1.5.1.7 25 x 2.5" Drive EXP configuration Drive configuration Table 5-37 Drive configuration Configuration Front Drive...
  • Page 94 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode ⚫ ⚫ ⚫ 25 x 2.5" drive Front drive: I/O module SAS/SATA 25 x 2.5" 1: 2 x 2.5" drive: 1 x...
  • Page 95 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode SAS/SAT A/NVMe drives ⚫ ⚫ ⚫ 25 x 2.5" drive Front drive: I/O module SAS/SATA drive: 1 x 25 x 2.5"...
  • Page 96 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-65 Drive slot numbers (2.5" drives in I/O module 1) Figure 5-66 Drive slot numbers (3.5" drives in I/O module 1) Table 5-38 Slot numbers Drive No. Drive Number Identified...
  • Page 97 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller ⚫ Drive slot numbers of 25 x 2.5" drive EXP configuration 3 and 25 x 2.5" drive EXP...
  • Page 98 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-67 Drive slot numbers (2.5" drives in I/O module 1) Figure 5-68 Drive slot numbers (3.5" drives in I/O module 1) Table 5-39 Slot numbers Drive No. Drive Number Identified...
  • Page 99 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller Note Note Note Note ⚫ Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can manage the drive and allocate a number to the drive.
  • Page 100 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-69 Slot numbers Table 5-40 Slot numbers Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller 2022-06-25...
  • Page 101: Drive Indicators

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller 5.1.5.2 Drive Indicators SAS/SATA Drive Indicators Figure 5-70 SAS/SATA drive indicators Table 5-41 SAS/SATA drive indicators...
  • Page 102 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Activity Indicator Fault Indicator Description (Green) (Yellow) Steady on Blinking at 1 Hz The drive is being located. Blinking at 1 Hz Blinking at 1 Hz Data on the secondary drive is being rebuilt.
  • Page 103 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Table 5-43 NVMe drive indicators (VMD disabled) Activity Indicator Fault Indicator Description (Green) (Yellow) The NVMe drive is not detected. Steady on The NVMe drive is detected and operating properly.
  • Page 104: Raid Controller Card

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description M.2 FRU Active M.2 FRU Fault Description Indicator (Green) Indicator (Yellow) is faulty. Steady on Steady on The M.2 FRU RAID status is abnormal. 5.1.5.3 RAID Controller Card The RAID controller card supports RAID configuration, RAID level migration, and drive roaming.
  • Page 105 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-73 PCIe slots − I/O module 1 provides slots 1, 2, and 3. If a two-slot PCIe riser module is used, slot 1 is unavailable. If a module with 2 x 2.5" drives and one PCIe card is used, slots 1 and 2 are unavailable.
  • Page 106 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-75 PCIe slots − PCIe riser module 1 provides slots 1, 2, 3, 4, 5 and 6. − PCIe riser module 2 provides slots 7, 8, and 9. −...
  • Page 107 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-77 PCIe riser module 2 ⚫ PCIe riser module 3 (universal) − Provides PCIe slots 2 and 3 when installed in I/O module 1. − Provides PCIe slots 5 and 6 when installed in I/O module 2.
  • Page 108 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description − Provides PCIe slots 2 and 3 when installed in I/O module 1. − Provides PCIe slots 5 and 6 when installed in I/O module 2. Figure 5-79 PCIe riser module 4 ⚫...
  • Page 109 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-80 2 x 2.5" drives + PCIe riser module ⚫ PCIe riser module 6 (applicable to the 20 x 2.5" drive pass-through configuration) − Provides PCIe slot 3 when installed in I/O module 1.
  • Page 110 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-82 PCIe riser module 7 ⚫ PCIe riser module 8 It provides PCIe slots 7 and 8 when being installed in I/O module 3. Figure 5-83 PCIe riser module 8 ⚫...
  • Page 111 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Provides PCIe slot 8 when installed in I/O module 3. Figure 5-84 PCIe riser module 9 PCIe Riser Modules (Applicable to the Server with Four GPU Cards on the Rear Panel) ⚫...
  • Page 112 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-85 PCIe riser module of the GPU card ⚫ PCIe riser module 3 PCIe riser module 3 provides slot 9. 2022-06-25...
  • Page 113 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-86 PCIe riser module ⚫ Adapter board 1 between layer 1 and layer 2 Installed next to CPU 1 to provide slots for PCIe riser module 1 at the upper layer.
  • Page 114 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-87 Adapter board 1 between layer 1 and layer 2 ⚫ Adapter board 2 between layer 1 and layer 2 Installed next to CPU 2 to provide slots for PCIe riser module 2 at the upper layer.
  • Page 115 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description PCIe Riser Modules (Applicable to the Server with 11 Standard PCIe cards on the Rear Panel) ⚫ PCIe riser module 1 Provides PCIe slots 1, 2, 3, 4, 5, and 6 when installed in PCIe riser module 1.
  • Page 116 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-90 PCIe riser module 2 ⚫ PCIe riser module 3 Provides PCIe slots 10, and 11 when installed in PCIe riser module 3. Figure 5-91 PCIe riser module 3...
  • Page 117: Pcie Slot Description

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description 5.1.7.3 PCIe Slot Description The PCIe slots mapping to a vacant CPU socket are unavailable. Server with Drive Modules or PCIe Riser Modules on the Rear Panel Table 5-45 PCIe slot description...
  • Page 118 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Device Slot Standa ctor Port (B/D/F Slot Width Size (B/D/F Width ⚫ dule with 2.5" driv card ⚫ Slot 2 CPU1 PCIe 3-sl Port2A 4A/02/...
  • Page 119 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Device Slot Standa ctor Port (B/D/F Slot Width Size (B/D/F Width ⚫ dule with 2.5" driv card ⚫ Slot4 CPU2 PCIe 3-sl Port0A 97/02/0 98/00/0...
  • Page 120 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Device Slot Standa ctor Port (B/D/F Slot Width Size (B/D/F Width ⚫ 2-sl ⚫ dule with 2.5" driv card Slot 6 CPU2 PCIe ⚫ 3-sl...
  • Page 121 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Device Slot Standa ctor Port (B/D/F Slot Width Size (B/D/F Width ⚫ 1-sl Slot 8 CPU2 PCIe ⚫ 2-sl Port3C E2/04/0 E4/00/0 FHHL ⚫ 1-sl ⚫...
  • Page 122 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Device Slot Standa ctor Port (B/D/F Slot Width Size (B/D/F Width Screw-i CPU1 PCIe Port0A 16/02/0 17/00/0 RAID controll er card FlexIO CPU1 PCIe Port0C...
  • Page 123 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Device Slot Standa ctor Port (B/D/F Slot Width Size (B/D/F Width ⚫ The full-height full-length (FHFL) PCIe slots are compatible with FHFL PCIe cards, full-height half-length (FHHL) PCIe cards, and half-height half-length (HHHL) PCIe cards.
  • Page 124: Psus

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Device Slot Standa ctor Port (B/D/F Slot Width Size (B/D/F Width Slot4 CPU1 PCIe Port2C 4A/04/ 4C/00/ HHHL Slot5 CPU1 PCIe Port3A 64/02/0 65/00/0 HHHL...
  • Page 125: Fan Modules

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description ⚫ If the DC power supply is used, purchase the DC power supply that meets the requirements of the safety standards or the DC power supply that has passed the CCC certification.
  • Page 126: Lcd

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-93 Positions of fan modules 5.1.10 LCD Only the 8 x 2.5" drive pass-through configuration supports the LCD. Function The LCD displays the installation status and running status of server components and enables users to set the IP address of the iBMC management network port on the server.
  • Page 127 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-94 LCD subsystem working principle Figure 5-95 LCD main interface Table 5-48 Parameters on the LCD home screen Function Status Displays the port 80 status, serial number, component status, and component alarms of the server.
  • Page 128 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Function temperature of the server. Info. Displays the IP address and MAC address of the iBMC management network port, device SNs, asset information, and firmware version. Setting Sets the IP address of the iBMC management network port.
  • Page 129: Boards

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description 5.1.11 Boards 5.1.11.1 Mainboard Figure 5-96 2288H V6-32DIMM mainboard PCIe riser 2 slot (PCIE Debugging pin (J103) RISER2/J51) Rear-drive backplane & BBU Screw-in RAID controller low-speed signal connector card connector (RAID (BACK HDD BP&BBU...
  • Page 130 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description (SLIMLINE7/J31) CONN/J109) Built-in storage expansion 2 x USB 3.0 ports (USB3.0 port (SD CARD/J87) CONN/J88) Rear VGA port (VGA Serial port (COM/J6020) CONN/J60) BMC management network BMC management board port (BMC_GE /J6019) LCD connector (LCD OCP 3.0 network adapter 1...
  • Page 131: Drive Backplane

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description (J102) FAN1/J67) Left mounting ear connector LP slimline 4 connector (LCIA BOARD/J106) (SLIMLINE4/J12) LP slimline 3 connector Power connector for the (SLIMLINE3/J85) built-in-drive backplane (INNER HDD PWR/J22) Drive backplane power...
  • Page 132 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-97 8 x 2.5" drive pass-through backplane Indicator signal cable DVD drive power connector connector (REAR BP1/J3) (DVD/J11) NOTE Reserved and unavailable currently. Backplane signal cable Power connector connector (HDD BP/J1)
  • Page 133 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-98 12 x 2.5" drive pass-through configuration (4 x SAS/SATA + 8 x NVMe) backplane LP slimline 2 connector LP slimline 1 connector (SLIM_2/J1001) (SLIM_1/J901) LP slimline 4 connector...
  • Page 134 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description (PORT A/J3) connector (REAR BP1/J8) Power connector (POWER/J1) ⚫ 12 x 3.5" drive NVMe backplane (4 x NVMe) This backplane is supported by 12 x 3.5" drive pass-through configuration 1 (4 x NVMe), 12 x 3.5"...
  • Page 135 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-101 12 x 3.5" drive EXP backplane Indicator signal cable Mini-SAS HD connector connector (REAR BP0/J31) (PORT A/J28) Mini-SAS HD connector Mini-SAS HD connector (PORT B/J29) (REAR PORT/J34) Backplane signal cable...
  • Page 136 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description (SLIMLINE 2B/J2001) (SLIMLINE 2A/J1901) Backplane signal cable Power connector 1 (HDD connector (HDD BP/J7102) POWER1/J30) Power connector 2 (HDD Mini-SAS HD connector POWER2/J7303) (PORT A/J1001) LP slimline 3 connector LP slimline 4 connector...
  • Page 137 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-104 24 x 2.5" drive pass-through backplane Mini-SAS HD connector Mini-SAS HD connector (PORT 3B/J33) (PORT 3A/J39) Mini-SAS HD connector Mini-SAS HD connector (PORT 2B/J31) (PORT 2A/J30) Mini-SAS HD connector...
  • Page 138 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Indicator signal cable connector (REAR BP1/J35) Built-in-Drive Backplane ⚫ 4 x 3.5" drive backplane Figure 5-106 4 x 3.5" drive backplane Mini-SAS HD connector Backplane signal cable (PORT A/J3) connector (INNER HDD...
  • Page 139 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description ⚫ 2 x 3.5" drive backplane Figure 5-108 2 x 3.5" drive backplane Indicator signal cable Mini-SAS HD connector connector (REAR BP/J5) (REAR PORT/J2) Power connector (BP PWR/J1) ⚫ 4 x 2.5" drive backplane Figure 5-109 4 x 2.5"...
  • Page 140: 2288H V6-16Dimm

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description 5.2 2288H V6-16DIMM 5.2.1 Front Panel 5.2.1.1 Appearance ⚫ 8 x 2.5" drive configuration Figure 5-110 Front view Drive (Optional) Built-in DVD drive (or LCD module) Slide-out label plate (with an SN label) ⚫...
  • Page 141: Indicators And Buttons

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-112 Front view Drive Slide-out label plate (with an SN label) 5.2.1.2 Indicators and Buttons Indicator and Button Positions ⚫ 8 x 2.5" drive configuration Figure 5-113 Indicators and buttons on the front panel...
  • Page 142 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Fault Diagnosis LED Power Button/Indicator Health status indicator UID button/indicator FlexIO card presence indicator ⚫ 25 x 2.5" drive configuration Figure 5-115 Indicators and buttons on the front panel Fault Diagnosis LED...
  • Page 143 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description [Azure] Indicator/Butt Description Available button to gracefully shut down the OS. NOTE For different OSs, you may need to shut down the OS as prompted. ⚫ When the device is powered on, you can hold down this button for 6 seconds to forcibly power off the device.
  • Page 144: Rear Panel

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description 5.2.2 Rear Panel 5.2.2.1 Appearance Figure 5-116 Rear view I/O module 1 PCIe Slot1 PCIe Slot2 PCIe Slot3 PCIe Slot4 I/O module 3 PSU 2 PSU 1 FlexIO card NOTE The FlexIO card slot supports OCP 3.0 network adapters.
  • Page 145: Indicators And Buttons

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description 5.2.2.2 Indicators and Buttons Indicator Positions Figure 5-117 Indicators on the rear panel Data transmission status Connection status indicator of indicator of the management the management network port network port...
  • Page 146: Interface

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Identifier Indicator State Description NOTE You can control the UID indicator status by pressing the UID button or using the iBMC. ⚫ PSU indicator Off: No power is supplied. ⚫...
  • Page 147 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Management network port Serial port Socket for PSU 1 Socket for PSU 2 Port Description Table 5-51 Ports on the rear panel Port Type Quantity Description VGA port DB15 Used to connect a display terminal, such as a monitor or KVM.
  • Page 148: Processor

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Port Type Quantity Description NOTE When determining the PSUs, ensure that the rated power of the PSUs is greater than that of the server. 5.2.3 Processor ⚫ The server supports one or two processors.
  • Page 149: Memory Subsystem Architecture

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-120 Memory identifier Description Example Capacity ⚫ 16 GB ⚫ 32 GB ⚫ 64 GB ⚫ 128 GB ⚫ rank(s) 1R = Single rank ⚫ 2R = Dual rank ⚫...
  • Page 150: Memory Compatibility

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Channel Memory Slot CPU 1 DIMM000(A) DIMM010(B) DIMM020(C) DIMM030(D) DIMM040(E) DIMM050(F) DIMM060(G) DIMM070(H) CPU 2 DIMM100(A) DIMM110(B) DIMM120(C) DIMM130(D) DIMM140(E) DIMM150(F) DIMM160(G) DIMM170(H) 5.2.4.1.3 Memory Compatibility Observe the following rules when configuring DDR4 memory modules: ⚫...
  • Page 151: Dimm Installation Rules

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description ⚫ For details about the capacity type of a single memory module, see "Search Parts" in the Compatibility Checker. ⚫ The maximum number of memory modules supported depends on the memory type and rank quantity.
  • Page 152: Memory Installation Positions

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description ⚫ Memory mirroring mode − Comply with the general installation guidelines. − Each processor supports four integrated memory controllers (IMCs), and each IMC has two channels for installing memory modules. The installed memory modules must be identical in size and organization.
  • Page 153: Memory Protection Technologies

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-122 DDR4 memory module installation guidelines (1 processor) Figure 5-123 DDR4 memory module installation guidelines (2 processors) 5.2.4.1.6 Memory Protection Technologies The following memory protection technologies are supported: ⚫...
  • Page 154: Storage

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description ⚫ Memory Mirroring ⚫ Memory Single Device Data Correction (SDDC) ⚫ Failed DIMM Isolation ⚫ Memory Thermal Throttling ⚫ Command/Address Parity Check and Retry ⚫ Memory Demand/Patrol Scrubbing ⚫ Memory Data Scrambling ⚫...
  • Page 155 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode only support card SAS/SAT only The PCIe A drives. NVMe RAID drives controller card must be installed in slot 1.
  • Page 156 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified by the iBMC ⚫ Drive slot numbers of 8 x 2.5" drive pass-through configuration 2 and 8 x 2.5" drive pass-through configuration 3 in Table 5-54...
  • Page 157: 12 X 3.5" Drive Pass-Through Configuration

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller 5.2.5.1.2 12 x 3.5" drive pass-through configuration Drive configuration Table 5-57 Drive configuration Configuration Front Drive...
  • Page 158 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode only NVMe drives ⚫ ⚫ ⚫ 12 x 3.5" drive Front drive: I/O module SAS/SATA pass-through drive: 1 x 12 x 3.5"...
  • Page 159 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode ⚫ ⚫ ⚫ 12 x 3.5" drive Front drive: I/O module SAS/SATA pass-through 12 x 3.5" 1: 2 x 3.5"...
  • Page 160 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified by the iBMC ⚫ Drive slot numbers of 12 x 3.5" drive pass-through configuration 2 and 12 x 3.5" drive pass-through configuration 3 in Table 5-57...
  • Page 161 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller ⚫ Drive slot numbers of 12 x 3.5" drive pass-through configuration 1 (4 x NVMe) in Table...
  • Page 162 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Table 5-60 Slot numbers Drive No. Drive Number Identified by the iBMC ⚫ Drive slot numbers of 12 x 3.5" drive pass-through configuration 2 (4 x NVMe) and 12 x 3.5"...
  • Page 163: 12 X 3.5" Drive Exp Configuration

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller Note Note Note Note Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can manage the drive and allocate a number to the drive.
  • Page 164 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode to 47 support only NVMe drives ⚫ ⚫ ⚫ 12 x 3.5" drive Front drive: I/O module SAS/SATA 12 x 3.5"...
  • Page 165 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode 3: 4 x 2.5" slot 1. ⚫ − Slots 44 NVMe to 47 drive: CPU support SAS/SAT A/NVMe drives 12 x 3.5" drive ⚫...
  • Page 166 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode ⚫ Contact your local sales representative or see "Search Parts" in the Compatibility Checker to determine the components to be used.
  • Page 167 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller ⚫ Drive slot numbers of 12 x 3.5" drive EXP configuration 3 and 12 x 3.5" drive EXP...
  • Page 168 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Table 5-64 Slot numbers Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller Note Note Note Note ⚫ Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can manage the drive and allocate a number to the drive.
  • Page 169 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-132 Slot numbers Table 5-65 Slot numbers Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller 2022-06-25...
  • Page 170: 25 X 2.5" Drive Exp Configuration

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description 5.2.5.1.4 25 x 2.5" drive EXP configuration Drive configuration Table 5-66 Drive configuration Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode ⚫ ⚫ ⚫ 25 x 2.5" drive...
  • Page 171 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode ⚫ I/O module 3: 4 x 2.5" − Slots 44 to 47 support SAS/SAT A/NVMe drives 25 x 2.5" drive ⚫...
  • Page 172 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Configuration Front Drive Rear Drive Built-in Drive Drive Management Mode SAS/SAT A drives in slots 40 to 41. − The PCIe RAID controlle r card manages SAS/SAT A drives in slots 0 to 24.
  • Page 173 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller 2022-06-25...
  • Page 174 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description ⚫ Drive slot numbers of 25 x 2.5" drive EXP configuration 3 and 25 x 2.5" drive EXP configuration 4 in Table 5-66 Figure 5-134 Slot numbers Table 5-68 Slot numbers Drive No.
  • Page 175 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller Note Note Note Note ⚫ Note: If the slot is configured with a SAS/SATA drive, the RAID controller card can manage the drive and allocate a number to the drive.
  • Page 176 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Table 5-69 Slot numbers Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller 2022-06-25...
  • Page 177: Drive Indicators

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Drive No. Drive Number Identified Drive Number Identified by the iBMC by the RAID Controller 5.2.5.2 Drive Indicators SAS/SATA Drive Indicators Figure 5-136 SAS/SATA drive indicators Table 5-70 SAS/SATA drive indicators...
  • Page 178 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description NVMe Drive Indicators Figure 5-137 NVMe drive indicators ⚫ If the VMD function is enabled and the latest VMD driver is installed, the NVMe drives support surprise hot swap. Table 5-71 NVMe drive indicators (VMD enabled)
  • Page 179: Raid Controller Card

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Activity Indicator Fault Indicator Description (Green) (Yellow) Blinking at 0.5 Hz The NVMe drive has completed the hot swap process and is removable. Steady on/Off Steady on The NVMe drive is faulty.
  • Page 180: Network

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description ⚫ Contact your local sales representative or see "Search Parts" in the Compatibility Checker to determine the components to be used. ⚫ For details about the RAID controller card, see V6 Server RAID Controller Card User Guide.
  • Page 181: Pcie Slots

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description 5.2.7.2 PCIe Slots PCIe Slots Figure 5-139 PCIe slots ⚫ I/O module 3 provides slots 5 and 6. If a one-slot PCIe riser module is used, slot 5 is unavailable.
  • Page 182 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-140 PCIe riser module ⚫ PCIe riser module Provides PCIe slot 6 when installed in I/O module 3. Figure 5-141 PCIe riser module 2022-06-25...
  • Page 183: Pcie Slot Description

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description 5.2.7.3 PCIe Slot Description The PCIe slots mapping to a vacant CPU socket are unavailable. Table 5-74 PCIe slot description PCIe PCIe Conne Port Root Device Slot Slot Standa ctor...
  • Page 184: Psus

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Device Slot Standa ctor Port (B/D/F Slot Width Size (B/D/F Width ⚫ 1-sl Slot6 CPU2 PCIe ⚫ 2-sl Port2C C9/4/0 CC/0/0 Full-hei ght and half-len ⚫...
  • Page 185: Fan Modules

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description ⚫ Contact your local sales representative or see "Search Parts" in the Compatibility Checker to determine the components to be used. Figure 5-142 PSU positions 5.2.9 Fan Modules ⚫ The server supports four fan modules.
  • Page 186: Lcd

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description 5.2.10 LCD Only the 8 x 2.5" drive pass-through configuration supports the LCD. Function The LCD displays the installation status and running status of server components and enables users to set the IP address of the iBMC management network port on the server.
  • Page 187 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-145 LCD main interface Table 5-75 Parameters on the LCD home screen Function Status Displays the port 80 status, serial number, component status, and component alarms of the server.
  • Page 188: Board

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description 5.2.11 Board 5.2.11.1 Mainboard Figure 5-146 2288H V6-16DIMM mainboard PCIe slot 4 (PCIE PCIe slot 3 (PCIE SLOT4/J2034) SLOT3/J2035) PCIe slot 2 (PCIE PCIe slot 1 (PCIE SLOT2/J2033) SLOT1/J2032) 2022-06-25...
  • Page 189 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description BMC management network USB 3.0 port (USB 3.0 port and management serial CONN/J17) port (BMC_GE/COM/J2038) LCD connector (LCD OCP 3.0 network adapter connector (OCP1 CONN/J9) CONN/J108) Built-in USB 3.0 connector VGA port (VGA (INNER USB 3.0/J110)
  • Page 190: Drive Backplane

    FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description (REAR 4*2.5 HDD BP/J57) a: Reserved and unavailable currently. 5.2.11.2 Drive Backplane Front hard disk backplane ⚫ 8 x 2.5" drive pass-through backplane All drive configurations in 5.2.5.1.1 8 x 2.5" drive pass-through configuration support this backplane.
  • Page 191 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description This backplane is supported by 12 x 3.5" drive pass-through configuration 1, 12 x 3.5" drive pass-through configuration 2, and 12 x 3.5" drive pass-through configuration 3 in 5.2.5.1.2 12 x 3.5" drive pass-through configuration.
  • Page 192 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Mini-SAS HD connector Mini-SAS HD connector (PORT B/J29) (PORT A/J28) Backplane signal cable Indicator signal cable connector (HDD_BP/J1) connector (REAR BP1/J31) Backplane power connector LP slimline 1 connector (HDD_BP/J24) (SLIMLINE 1/J4)
  • Page 193 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-151 25 x 2.5" drive backplane Indicator signal cable Mini-SAS HD connector connector (REAR BP0/J32) (PORT A/J28) Mini-SAS HD connector Mini-SAS HD connector (PORT B/J29) (REAR PORT/J31) Backplane signal cable...
  • Page 194 FusionServer 2288H V6 Server Technical White Paper 5 Hardware Description Figure 5-153 2 x 3.5" drive backplane Indicator signal cable mini-SAS HD connector connector (REAR BP/J5) (REAR PORT/J2) Power connector (BP PWR/J1) ⚫ 4 x 2.5" drive backplane Figure 5-154 4 x 2.5" drive backplane...
  • Page 195: Product Specifications

    FusionServer 2288H V6 Server Technical White Paper 6 Product Specifications Product Specifications 6.1 2288H V6-32DIMM 6.2 2288H V6-16DIMM 6.1 2288H V6-32DIMM 6.1.1 Technical Specifications Table 6-1 Technical specifications Component Specifications Form factor 2U rack server ® Chipset Intel C621A Processor Supports one or two processors.
  • Page 196 FusionServer 2288H V6 Server Technical White Paper 6 Product Specifications Component Specifications − RDIMM and LRDIMM support − Max. 3200 MT/s memory speed − The DDR4 memory modules of different types (RDIMM and LRDIMM) and specifications (capacity, bit width, rank, and height) cannot be used together.
  • Page 197 FusionServer 2288H V6 Server Technical White Paper 6 Product Specifications Component Specifications The NVMe drives support: ⚫ Before using the VMD function, contact technical support engineers of the OS vendor to check whether the OS supports the VMD function. If yes, check whether the VMD driver needs to be manually installed and check the installation method.
  • Page 198 FusionServer 2288H V6 Server Technical White Paper 6 Product Specifications Component Specifications NOTE The preceding information is for reference only. For details, see "Search Parts" in the Compatibility Checker. Port Supports a variety of ports. ⚫ Ports on the front panel: −...
  • Page 199: Environmental Specifications

    FusionServer 2288H V6 Server Technical White Paper 6 Product Specifications 6.1.2 Environmental Specifications Table 6-2 Environmental specifications Category Specifications Temperature ⚫ Operating temperature: 5° C to 45° C (41° F to 113° F) (ASHRAE Classes A1 to A4 compliant) Storage temperature (within three months): –30° C to +60° C ⚫...
  • Page 200: Physical Specifications

    FusionServer 2288H V6 Server Technical White Paper 6 Product Specifications Category Specifications of ISO 14664-1 Class 8. ⚫ There is no explosive, conductive, magnetic, or corrosive dust in the equipment room. NOTE It is recommended that the particulate pollutants in the equipment room be monitored by a professional organization.
  • Page 201 FusionServer 2288H V6 Server Technical White Paper 6 Product Specifications Item Description NOTE ⚫ See Figure 6-1 for methods in measuring physical dimensions of the chassis. ⚫ Methods measuring 3.5" and 2.5" drive chassis are the same. The 3.5" drive chassis is used as an example.
  • Page 202: 2288H V6-16Dimm

    FusionServer 2288H V6 Server Technical White Paper 6 Product Specifications Item Description 25.5 kg (56.22 lb) − Maximum weight for server with 20 x 2.5" front drives: 25.5kg (56.22 lb) ⚫ Packaging materials: 5 kg (11.03 lb) Energy consumption The power consumption parameters vary with hardware configurations (including the configurations complying with EU ErP).
  • Page 203 FusionServer 2288H V6 Server Technical White Paper 6 Product Specifications Component Specifications − A server must use DDR4 memory modules of the same part number (P/N code). NOTE The preceding information is for reference only. For details, see "Search Parts" in the Compatibility Checker.
  • Page 204 FusionServer 2288H V6 Server Technical White Paper 6 Product Specifications Component Specifications NOTE If the BIOS is in legacy mode, the 4K drive cannot be used as the boot drive. Network Supports expansion capability of multiple types of networks. ⚫...
  • Page 205: Environmental Specifications

    FusionServer 2288H V6 Server Technical White Paper 6 Product Specifications Component Specifications ⚫ iBMC ⚫ NC-SI ⚫ Integration with third-party management systems Security feature ⚫ Power-on password ⚫ Administrator password ⚫ TCM (only in China)/TPM ⚫ Secure boot ⚫ Front bezel (optional) ⚫...
  • Page 206 FusionServer 2288H V6 Server Technical White Paper 6 Product Specifications Category Specifications highest operating temperature decreases by 1° C (1.8° F) for every increase of 175 m (574.14 ft). ⚫ When the server configuration complies with ASHRAE Class A4 and the altitude is above 900 m (2952.76 ft), the highest operating temperature decreases by 1°...
  • Page 207: Physical Specifications

    FusionServer 2288H V6 Server Technical White Paper 6 Product Specifications ⚫ 6 months in unpacked/packed and powered-off state ⚫ The maximum preservation duration is determined according to the preservation specifications provided by drive vendors. For details, see the manuals provided by drive vendors.
  • Page 208 FusionServer 2288H V6 Server Technical White Paper 6 Product Specifications Category Description − Ball bearing rail kit: applies to cabinets with a distance of 609 mm to 950 mm (23.98 in. to 37.40 in.) between the front and rear mounting bars.
  • Page 209: Software And Hardware Compatibility

    FusionServer 2288H V6 Server Technical White Paper 7 Software and Hardware Compatibility Software and Hardware Compatibility Use the Compatibility Checker to obtain information about the operating systems and hardware supported. ⚫ If incompatible components are used, the device may be abnormal. This fault is beyond the scope of technical support and warranty.
  • Page 210: Safety Instructions

    FusionServer 2288H V6 Server Technical White Paper 8 Safety Instructions Safety Instructions 8.1 Security 8.2 Maintenance and Warranty 8.1 Security General Statement ⚫ Comply with local laws and regulations when installing devices. These Safety Instructions are only a supplement. ⚫...
  • Page 211 FusionServer 2288H V6 Server Technical White Paper 8 Safety Instructions Figure 8-1 Safety work wear ⚫ Before touching a device, wear ESD clothing and gloves (or wrist strap), and remove any conductive objects (such as watches and jewelry). Figure 8-2 shows conductive objects that must be removed before you touch a device.
  • Page 212 FusionServer 2288H V6 Server Technical White Paper 8 Safety Instructions Figure 8-3 Wearing an ESD wrist strap ⚫ Exercise caution when using tools. ⚫ If the installation position of a device is higher than the shoulders of the installation personnel, use a vehicle such as a lift to facilitate installation. Prevent the device from falling down and causing personal injury or damage to the device.
  • Page 213: Maintenance And Warranty

    FusionServer 2288H V6 Server Technical White Paper 8 Safety Instructions ⚫ Transport each device in its original packaging. ⚫ If the original packaging is unavailable, package heavy, bulky parts (such as chassis and blades) and fragile parts (such as PCIe cards and optical modules) separately.
  • Page 214: System Management

    FusionServer 2288H V6 Server Technical White Paper 9 System Management System Management This product integrates the new-generation Intelligent Baseboard Management Controller (iBMC), which complies with Intelligent Platform Management Interface 2.0 (IPMI 2.0) specifications and provides reliable hardware monitoring and management.
  • Page 215 FusionServer 2288H V6 Server Technical White Paper 9 System Management − Multiple types of certificates can be imported and replaced to ensure data transmission security. ⚫ System maintenance interface − The virtual KVM and virtual media functions facilitate remote maintenance.
  • Page 216: Certifications

    FusionServer 2288H V6 Server Technical White Paper 10 Certifications Certifications Country/Region Certification Standards Europe WEEE 2012/19/EU Europe REACH EC NO. 1907/2006 Europe Safety: EN 62368-1:2014+A11:2017 EMC: EN 55032:2015+A11:2020 CISPR 32:2015+A1:2019 EN IEC 61000-3-2:2019+A1:2021 EN 61000-3-3:2013+A1:2019 EN 55035:2017+A11:2020 CISPR 35:2016 EN 55024:2010+A1:2015 CISPR 24:2010+A1:2015 ETSI EN 300 386 V1.6.1:2012...
  • Page 217 FusionServer 2288H V6 Server Technical White Paper 10 Certifications Country/Region Certification Standards EN 55032:2015+A11:2020 CISPR 32:2015+A1:2019 EN IEC 61000-3-2:2019+A1:2021 EN 61000-3-3:2013+A1:2019 EN 55035:2017+A11:2020 CISPR 35:2016 EN 55024:2010+A1:2015 CISPR 24:2010+A1:2015 ETSI EN 300 386 V1.6.1:2012 ETSI EN 300 386 V2.1.1:2016 RoHS:...
  • Page 218: A Appendix

    FusionServer 2288H V6 Server Technical White Paper A Appendix Appendix A.1 Chassis Label The label information and location are for reference only. For details, see the actual product. A.1.1 On the Front Top Figure A-1 Chassis head label Nameplate Certificate...
  • Page 219 FusionServer 2288H V6 Server Technical White Paper A Appendix device. A.1.1.1 Nameplate Figure A-2 Nameplate example Table A-1 Nameplate description Description Server Model For details, see A.4 Nameplate. Device names Power Supply Requirements Vendor Information Authentication ID A.1.1.2 Certificate Figure A-3 Sample certificate of conformity...
  • Page 220 FusionServer 2288H V6 Server Technical White Paper A Appendix Table A-2 Certificate of conformity description Description Order NOTE For details, see Figure A-4 and Table A-3. QC inspector Production date No. Barcode Figure A-4 Sample certificate number Table A-3 Certificate No. Description Description "P", fixed...
  • Page 221 FusionServer 2288H V6 Server Technical White Paper A Appendix Description ⚫ Letters A to H indicate 10 to 17:00. ⚫ Letters J to N indicate 18 to 22:00. ⚫ Letters P to Q indicate 23 to 24:00. Serial number (2 digits) Manufacturing serial number (5 digits).
  • Page 222 FusionServer 2288H V6 Server Technical White Paper A Appendix A.1.2 Chassis Tail Label Figure A-6 Chassis tail label For details about the warning label, see Server Security Information. A.1.3 Chassis Internal Label Figure A-7 Chassis internal label ⚫ The quick guide is located on the inside of the chassis cover. It describes how to remove the mainboard components, important components of the chassis, precautions, and QR codes of technical resources.
  • Page 223 FusionServer 2288H V6 Server Technical White Paper A Appendix Figure A-8 SN example Table A-5 SN description Description ESN ID (two characters), which can only be 21. Material ID (eight characters), that is, the processing code. Vendor code (two characters), that is, the code of the processing place.
  • Page 224 FusionServer 2288H V6 Server Technical White Paper A Appendix Configurat Maximum Maximum Maximum Maximum Maximum Operating Operating Operating Operating Operating Temperatu Temperatu Temperatu Temperatu Temperatu re 30° C re 35° C re 40° C re 45° C re 50° C (86°...
  • Page 225 FusionServer 2288H V6 Server Technical White Paper A Appendix Configurat Maximum Maximum Maximum Maximum Maximum Operating Operating Operating Operating Operating Temperatu Temperatu Temperatu Temperatu Temperatu re 30° C re 35° C re 40° C re 45° C re 50° C (86°...
  • Page 226 FusionServer 2288H V6 Server Technical White Paper A Appendix Configurat Maximum Maximum Maximum Maximum Maximum Operating Operating Operating Operating Operating Temperatu Temperatu Temperatu Temperatu Temperatu re 30° C re 35° C re 40° C re 45° C re 50° C (86°...
  • Page 227 FusionServer 2288H V6 Server Technical White Paper A Appendix Configurat Maximum Maximum Maximum Maximum Maximum Operating Operating Operating Operating Operating Temperatu Temperatu Temperatu Temperatu Temperatu re 30° C re 35° C re 40° C re 45° C re 50° C (86°...
  • Page 228 FusionServer 2288H V6 Server Technical White Paper A Appendix Configurat Maximum Maximum Maximum Maximum Maximum Operating Operating Operating Operating Operating Temperatu Temperatu Temperatu Temperatu Temperatu re 30° C re 35° C re 40° C re 45° C re 50° C (86°...
  • Page 229 FusionServer 2288H V6 Server Technical White Paper A Appendix Configurat Maximum Maximum Maximum Maximum Maximum Operating Operating Operating Operating Operating Temperatu Temperatu Temperatu Temperatu Temperatu re 30° C re 35° C re 40° C re 45° C re 50° C (86°...
  • Page 230 FusionServer 2288H V6 Server Technical White Paper A Appendix Configurat Maximum Maximum Maximum Maximum Maximum Operating Operating Operating Operating Operating Temperatu Temperatu Temperatu Temperatu Temperatu re 30° C re 35° C re 40° C re 45° C re 50° C (86°...
  • Page 231 FusionServer 2288H V6 Server Technical White Paper A Appendix Configurat Maximum Maximum Maximum Maximum Maximum Operating Operating Operating Operating Operating Temperatu Temperatu Temperatu Temperatu Temperatu re 30° C re 35° C re 40° C re 45° C re 50° C (86°...
  • Page 232 FusionServer 2288H V6 Server Technical White Paper A Appendix Configurat Maximum Maximum Maximum Maximum Maximum Operating Operating Operating Operating Operating Temperatu Temperatu Temperatu Temperatu Temperatu re 30° C re 35° C re 40° C re 45° C re 50° C (86°...
  • Page 233 FusionServer 2288H V6 Server Technical White Paper A Appendix Configurat Maximum Maximum Maximum Maximum Maximum Operating Operating Operating Operating Operating Temperatu Temperatu Temperatu Temperatu Temperatu re 30° C re 35° C re 40° C re 45° C re 50° C (86°...
  • Page 234 FusionServer 2288H V6 Server Technical White Paper A Appendix Configurat Maximum Maximum Maximum Maximum Maximum Operating Operating Operating Operating Operating Temperatu Temperatu Temperatu Temperatu Temperatu re 30° C re 35° C re 40° C re 45° C re 50° C (86°...
  • Page 235 FusionServer 2288H V6 Server Technical White Paper A Appendix Configurat Maximum Maximum Maximum Maximum Maximum Operating Operating Operating Operating Operating Temperatu Temperatu Temperatu Temperatu Temperatu re 30° C re 35° C re 40° C re 45° C re 50° C (86°...
  • Page 236 FusionServer 2288H V6 Server Technical White Paper A Appendix Configurat Maximum Maximum Maximum Maximum Maximum Operating Operating Operating Operating Operating Temperatu Temperatu Temperatu Temperatu Temperatu re 30° C re 35° C re 40° C re 45° C re 50° C (86°...
  • Page 237 FusionServer 2288H V6 Server Technical White Paper A Appendix Configurat Maximum Maximum Maximum Maximum Maximum Operating Operating Operating Operating Operating Temperatu Temperatu Temperatu Temperatu Temperatu re 30° C re 35° C re 40° C re 45° C re 50° C (86°...
  • Page 238 FusionServer 2288H V6 Server Technical White Paper A Appendix Configuration Maximum Maximum Maximum Maximum Operating Operating Operating Operating Temperature Temperature Temperature Temperature 30° C (86° F) 35° C (95° F) 40° C (104° F) 45° C (113° F) supported. ⚫...
  • Page 239 FusionServer 2288H V6 Server Technical White Paper A Appendix Configuration Maximum Maximum Maximum Maximum Operating Operating Operating Operating Temperature Temperature Temperature Temperature 30° C (86° F) 35° C (95° F) 40° C (104° F) 45° C (113° F) supported 8380...
  • Page 240 FusionServer 2288H V6 Server Technical White Paper A Appendix Configuration Maximum Maximum Maximum Maximum Operating Operating Operating Operating Temperature Temperature Temperature Temperature 30° C (86° F) 35° C (95° F) 40° C (104° F) 45° C (113° F) /6338 ⚫...
  • Page 241 FusionServer 2288H V6 Server Technical White Paper A Appendix Configuration Maximum Maximum Maximum Maximum Operating Operating Operating Operating Temperature Temperature Temperature Temperature 30° C (86° F) 35° C (95° F) 40° C (104° F) 45° C (113° F) are not supported.
  • Page 242 FusionServer 2288H V6 Server Technical White Paper A Appendix A.6 Sensor List A.6.1 2288H V6-32DIMM Sensor Description Component Inlet Temp Air inlet temperature Right mounting ear Outlet Temp Air outlet temperature BMC card PCH Temp PCH bridge temperature Mainboard CPUN Core Rem...
  • Page 243 FusionServer 2288H V6 Server Technical White Paper A Appendix Sensor Description Component voltage N indicates the CPU number. The value is 1 or 2. CPUN VCCIN CPU VCCIN voltage Mainboard N indicates the CPU number. The value is 1 or 2.
  • Page 244 FusionServer 2288H V6 Server Technical White Paper A Appendix Sensor Description Component number. The value is 1 or 2. CPUN Memory Status of the memory Memory module corresponding to the CPU corresponding to CPU N N indicates the CPU number. The value is 1 or 2.
  • Page 245 FusionServer 2288H V6 Server Technical White Paper A Appendix Sensor Description Component LCD Status LCD health status LCD Presence LCD presence PS Redundancy Redundancy failure due to Power supply unit (PSU) PSU removal PSN Status PSU status PSU N N indicates the PSU number.
  • Page 246 FusionServer 2288H V6 Server Technical White Paper A Appendix Sensor Description Component FPGA$ OP Temp FPGA card optical module PCIe card temperature PCIe$ Inlet Temp PCIe smart card air inlet PCIe smart cards temperature PCIe$ Cpu Temp PCIe smart card CPU...
  • Page 247 FusionServer 2288H V6 Server Technical White Paper A Appendix Sensor Description Component GPU$ DDR Temp DDR chip temperature of GPU cards the GPU card GPU$ HBM Temp HBM chip temperature of GPU cards the GPU card System Notice Hot restart reminder and...
  • Page 248 FusionServer 2288H V6 Server Technical White Paper A Appendix A.6.2 2288H V6-16DIMM Sensor Description Component Inlet Temp Air inlet temperature Mainboard Outlet Temp Air outlet temperature BMC card PCH Temp PCH bridge temperature Mainboard CPUN Core Rem CPU core temperature...
  • Page 249 FusionServer 2288H V6 Server Technical White Paper A Appendix Sensor Description Component CPUN VSA CPU VSA voltage Mainboard N indicates the CPU number. The value is 1 or 2. CPUN P1V8 CPU P1V8 voltage Mainboard N indicates the CPU number. The value is 1 or 2.
  • Page 250 FusionServer 2288H V6 Server Technical White Paper A Appendix Sensor Description Component FANN Status Fan fault status Fan module N N indicates the fan module number. The value ranges from 1 to 4. DIMMN DIMM status DIMM N N indicates the DIMM slot number.
  • Page 251 FusionServer 2288H V6 Server Technical White Paper A Appendix Sensor Description Component PSN Fan Status PSU fan fault status PSU N N indicates the PSU number. The value is 1 or 2. PSN Temp Status PSU presence PSU N N indicates the PSU number.
  • Page 252 FusionServer 2288H V6 Server Technical White Paper A Appendix Sensor Description Component PS$ IIn PSU input current Power supply unit (PSU) PS$ IOut PSU output current Power supply unit (PSU) PS$ Pout PSU output power Power supply unit (PSU) PS$ Temp...
  • Page 253 FusionServer 2288H V6 Server Technical White Paper A Appendix Sensor Description Component information collection System Error System suspension or restart. Check the background logs. ACPI State ACPI status SysFWProgress Software process and system startup errors SysRestart Cause of system restart...
  • Page 254: B Glossary

    FusionServer 2288H V6 Server Technical White Paper B Glossary Glossary B.1 A-E The baseboard management controller (BMC) complies with the Intelligent Platform Management Interface (IPMI). It collects, processes, and stores sensor signals, and monitors the operating status of components. The BMC provides the...
  • Page 255 FusionServer 2288H V6 Server Technical White Paper B Glossary hot swap Replacing or adding components without stopping or shutting down the system. B.3 K-O A hardware device that provides public video, keyboard and mouse (KVM). B.4 P-T panel An external component (including but not limited to ejector levers, indicators, and ports) on the front or rear of the server.
  • Page 256 FusionServer 2288H V6 Server Technical White Paper B Glossary system event log Event records stored in the system used for subsequent fault (SEL) diagnosis and system recovery. B.5 U-Z A unit defined in International Electrotechnical Commission (IEC) 60297-1 to measure the height of a cabinet, chassis, or subrack.
  • Page 257 FusionServer 2288H V6 Server Technical White Paper C Acronyms and Abbreviations Acronyms and Abbreviations C.1 A-E alternating current Advanced Encryption Standard New Instruction Set Address Resolution Protocol Advanced Vector Extensions backup battery unit BIOS Basic Input/Output System baseboard management controller...
  • Page 258 FusionServer 2288H V6 Server Technical White Paper C Acronyms and Abbreviations direct current DDR4 Double Data Rate 4 DDDC double device data correction DEMT Dynamic Energy Management Technology DIMM dual in-line memory module DRAM dynamic random-access memory digital video disc...
  • Page 259 FusionServer 2288H V6 Server Technical White Paper C Acronyms and Abbreviations high availability hard disk drive high-performance computing HTTP Hypertext Transfer Protocol HTTPS Hypertext Transfer Protocol Secure iBMC intelligent baseboard management controller Industry Canada ICMP Internet Control Message Protocol Internet Data Center...
  • Page 260 FusionServer 2288H V6 Server Technical White Paper C Acronyms and Abbreviations LRDIMM load-reduced dual in-line memory module light emitting diode LAN on motherboard media access control module management controller next business day NC-SI Network Controller Sideband Interface Open Compute Project C.4 P-T...
  • Page 261 FusionServer 2288H V6 Server Technical White Paper C Acronyms and Abbreviations reliability, availability and serviceability RDIMM registered dual in-line memory module REACH Registration Evaluation and Authorization of Chemicals RJ45 registered jack 45 RoHS Restriction of the Use of Certain Hazardous Substances in...
  • Page 262 FusionServer 2288H V6 Server Technical White Paper C Acronyms and Abbreviations Trusted Execution Technology TransFlash module TFTP Trivial File Transfer Protocol TCP offload engine trusted platform module C.5 U-Z UDIMM unbuffered dual in-line memory module UEFI Unified Extensible Firmware Interface unit identification light Underwriter Laboratories Inc.