Note 1: Personal computer
(The SeusEX must be installed in the PC.)
OS:
Windows Vista / 7
RAM:
256 MB or more recommended (Windows 7)
1 GB or more recommended (Windows Vista)
USB port: USB 2.0 recommended (also compatible with 1.1)
Two connectors are required.
Run time:
.NET Framework 2.0
(.NET Framework 2.0 is installed at lens adjustment program installation, if it is not installed.)
Note 2: Attach the chart to the 1000 mm collimator as shown in Fig. 4-1-2.
Align the marks
Chart
1000 mm collimator
Fig. 4-1-2
SEL2470GM (FE 2.8 / 24-70 GM) (FE 24-70mm F2.8 GM)
4-1-3. Preparations for Equipments
(1) Setting of Equipments
Set the equipments and the lens to be tested as shown below.
Flange back
adjustment jig
(J-6082-563-A)
FB Adjustment chart
or
Siemens star chart
(J-6080-875-A)
USB cable
(1-829-868-41)
Personal computer
To USB connector
(The SeusEX must be installed in the PC.)
OS:
Windows Vista / 7
RAM:
256 MB or more recommended (Windows 7)
1 GB or more recommended (Windows Vista)
USB port:
USB 2.0 recommended (also compatible with 1.1)
Two connectors are required.
Run time:
.NET Framework 2.0
(.NET Framework 2.0 is installed at lens adjustment
program installation, if it is not installed.)
4-2
・In the case of zoom lens
・In the case of fixed focal lens
Within 10 mm
Within 10 mm
Flange back
Flange back
adjustment jig
adjustment jig
Lens to be tested
AC adaptor
(AC-PW20)
(1-487-963-12:EXCEPT US, CND)
(1-487-963-22:US, CND)
Lens to
be tested
Camera
To USB connector
(ILCE-5000)
To tripod screw
Tripod
(optional)
HASP key
Fig. 4-1-3
Lens to be tested
AC