For environmental specifications, refer to chapter 1.

EMC Emissions and Immunity Specifications

EMC EMISSIONS
Emissions
EMC IMMUNITY
Electrostatic Discharge
RF Susceptibility
Fast Transient
Surge
Conducted RF Immunity
1
Magnetic Field Immunity
Damped Oscillatory Wave
1) Applies only to IPCs with magnetic hard drive (ICRXIBNxM00xA).
2) EN 61000-4-x series of tests are technically equivalent to the IEC 61000-4-x series.
GFK-2785C
CISPR 11/EN 55011/
30 – 1000 MHz, radiated, Group 1, Class A,
EN55016-2-3
FCC 47CFR15
30 – 7500 MHz, radiated, Class A
CISPR 22/EN55022
30 – 6000 MHz, radiated, Class A,
Ethernet port: 0.15 – 30 MHz, conducted, Class A
2
8.0 kV air, 4.0 kV contact,
EN61000-4-2
/EN55024/CISPR 24/
2
EN 61000-4-3
1kHz sine wave, 80% AM
2
DC Input: 2 kV, 33 nF direct
EN 61000-4-4
Video and Ethernet ports, shielded:
RS-232 port, unshielded:
2
EN 61000-4-5
DC Input: 0.5 kV, 12 ohms (CM); 0.5 kV, 2 ohms (DM)
Ethernet port, shielded: ±1.0 kV, 2 ohms (CM)
2
DC Input: 10 V, CDN
EN 61000-4-6
Video and Ethernet ports, shielded:
RS-232 port, unshielded:
EN61000-4-8
50 and 60 Hz, 30 A/m
2
DC Input: 2. 5kV, 1 MHz (CM/DM);
EN 61000-4-18
Video and Ethernet ports, shielded:
RS-232 port, unshielded:
PACSystems* RXi Box IPC
10 V/m, 80 – 1000 MHz
3 V/m, 1.0 – 2.0 GHz
1 V/m, 2.0 – 2.7 GHz
1.1 kV, capacitive clamp
1.1 kV, capacitive clamp
10 V, current clamp
10 V, current clamp
2.5 kV, 1 MHz (CM)
2.5 kV, 1 MHz (CM)