●A008 Compatibility error in the view restrictions settings (warning)
unacceptable view restriction for camera[1]
Message
Explanation
Even in the telephoto field of view, the view restriction settings cannot be
satisfied in the horizontal or vertical direction. When this occurs, the zoom
setting is fixed at the telephoto field of view, and camera head control is
prohibited in directions that do not satisfy the permitted field of view restrictions.
Set appropriate values for the view restrictions.
Response
●A010 Camera control driver start and stop (info)
%1 driver for camera[1] %2
Message
Camera type (Canon VB-C50i | Canon VB-C50iR)
%1
started | stopped
%2
The camera control device was detected and the driver started up, or a
Explanation
camera control device error was detected and the driver stopped.
●A011 Camera control device error (warning)
%1[1] malfunction (%2)
Message
Camera type (Canon VB-C50i | Canon VB-C50iR)
%1
Error (read | write | timeout | ...)
%2
Camera control device I/O error.
Explanation
Response
There is a malfunction if it occurs repeatedly. Contact an authorized Canon
service representative.
●A012 WebView Livescope client start and stop (info)
%1@%2 %3
Message
Client type (LS/D | LS/H)
%1
Client host IP address
%2
connected | closed
%3
Connection and disconnection of TCP version WebView client (LS/D) and
Explanation
HTTP version WebView client (LS/H) excluding still images.
●A014 Access prohibited due to host restriction (notice)
LS@%1 access denied
Message
Client host IP address
%1
Access from the client was denied due to host restrictions.
Explanation