Speed Measurement System - ABB TPL69-A33 Series Operation Manual

Hide thumbs Also See for TPL69-A33 Series:
Table of Contents

Advertisement

6.5
6.5
© Copyright 2016 ABB. All rights reserved.
Operation Manual / TPL65-A32 / -A33 / -A36 + TPL69-A32 / -A33
Troubleshooting

Speed measurement system

Speed measurement system
Possible causes
Signal
Fitting error
amplitude non
existent or
poor
Defective sensor Contact ABB Turbocharging service station.
Measured
Dirty sensor tip
speeds too
high
Measured
- -
speed too low
Other sources
- -
of errors
6
6.5
Elimination
The screw plug for the sensor is fitted with a
gasket.
When fitting the speed sensor, this gasket
must be removed. If it is fitted by mistake,
the distance from the sensor tip to the sig-
nal-generating sealing disc increases. As a
result, the voltage amplitude of the speed
signal decreases, which can cause problems
for the evaluation electronics.
This problem is eliminated by removing the
gasket.
The sensor tip is magnetic and can thus at-
tract metal particles. As a result, the dis-
tance to the auxiliary bearing decreases,
which can lead to amplification of the noise
component and consequently to faulty trig-
gering.
Remove the sensor, clean its tip and refit the
sensor using the specified tightening torque.
Contact ABB Turbocharging service station.
If none of the above measures eliminates
the problem, we recommend that you have
the speed measuring system inspected by
an official ABB Turbocharging service sta-
tion.
Page 79

Advertisement

Table of Contents
loading

Table of Contents